1、AN AM E R IC A N NAT IO NAL STANDARDASME B16.29-2017(Revision of ASME B16.29-2012)Wrought Copper and Wrought Copper Alloy Solder-Joint Drainage Fittings DWVASME B16.29-2017(Revision of ASME B16.29-2012)Wrought Copper andWrought Copper AlloySolder-Joint DrainageFittings DWVAN AMERICAN NATIONAL STANDA
2、RDDate of Issuance:December 29,2017The next edition of this Standard is scheduled for publication in 2022.ASME issues written replies to inquiries concerning interpretations of technical aspects of this Standard.Interpretations arepublished on the ASME Web site under the Committee Pages at http:/cst
3、ools.asme.org/as they are issued.Errata to codes and standards may be posted on the ASME Web site under the Committee Pages to provide corrections toincorrectlypublisheditems,ortocorrecttypographicalorgrammaticalerrorsincodesandstandards.Sucherratashallbeusedon the date posted.TheCommitteePagescanbe
4、foundathttp:/cstools.asme.org/.Thereisanoptionavailabletoautomaticallyreceiveane-mailnotification when errata are posted to a particular code or standard.This option can be found on the appropriate CommitteePage after selecting“Errata”in the“Publication Information”section.ASME is the registered tra
5、demark of The American Society of Mechanical Engineers.ThiscodeorstandardwasdevelopedunderproceduresaccreditedasmeetingthecriteriaforAmericanNationalStandards.TheStandardsCommitteethatapprovedthecodeorstandardwasbalancedtoassurethatindividualsfromcompetentandconcernedinterestshavehadanopportunityto
6、participate.The proposed codeorstandardwasmadeavailable forpublic reviewandcommentthatprovidesanopportunityfor additional public input from industry,academia,regulatory agencies,and the public-at-large.ASME does not“approve,”“rate,”or“endorse”any item,construction,proprietary device,or activity.ASME
7、 does not take any position with respect to the validity of any patent rights asserted in connection with any items mentioned in thisdocument,anddoesnotundertaketoinsureanyoneutilizingastandardagainstliabilityforinfringementofanyapplicableletterspatent,norassumeanysuchliability.Usersofacodeorstandar
8、dareexpresslyadvisedthatdeterminationofthevalidityofanysuchpatentrights,andtherisk of infringement of such rights,is entirely their own responsibility.Participation by federal agency representative(s)or person(s)affiliated with industry is not to be interpreted as government or industryendorsement o
9、f this code or standard.ASME accepts responsibility for only those interpretations of this document issued in accordance with the established ASME proceduresand policies,which precludes the issuance of interpretations by individuals.No part of this document may be reproduced in any form,in an electr
10、onic retrieval system or otherwise,without the prior written permission of the publisher.The American Society of Mechanical EngineersTwo Park Avenue,New York,NY 10016-5990Copyright 2017 byTHE AMERICAN SOCIETY OF MECHANICAL ENGINEERSAll rights reservedPrinted in U.S.A.CONTENTSForeword.vCommittee Rost
11、er.viCorrespondence With the B16 Committee.viiSummary of Changes.ixList of Changes in Record Number Order.x1Scope.12General.13Description.14Pitch(Slope).15Abbreviations.16Component Size.17Marking.28Material.29Laying Lengths.210Ovality.211Threaded Ends.212Design of Threaded Ends.213Alignment.214Gagin
12、g.3Mandatory AppendicesIU.S.Customary Dimensions.14IIReferences.25Nonmandatory AppendixAQuality System Program.26Figure1Size of Fittings.2Tables1Dimensions of Solder-Joint Ends.42Dimensions of Threaded Ends DWV.53Dimensions of DWV Couplings,Extended Bushings,and Adapters.64Dimensions of DWV Soil Pip
13、e Adapters.75Dimensions of DWV C No-Hub Soil Pipe Adapters.86Dimensions of DWV Elbows.97Dimensions of DWV 45 deg Ys.10iii8Dimensions of DWV Tees.119Dimensions of DWV Caps.1110Dimensions of DWV Vent Increasers.1111Dimensions of DWV Closet Flanges.1212Dimensions of DWV Trap Adapters.1313Dimensions of
14、DWV Slip-Joint Ends.13I-1Dimensions of Solder-Joint Ends.15I-2Dimensions of Threaded Ends DWV.16I-3Dimensions of DWV Couplings,Extended Bushings,and Adapters.17I-4Dimensions of DWV Soil Pipe Adapters.18I-5Dimensions of DWV C No-Hub Soil Pipe Adapters.19I-6Dimensions of DWV Elbows.20I-7Dimensions of
15、DWV 45 deg Ys.21I-8Dimensions of DWV Tees.22I-9Dimensions of DWV Caps.22I-10Dimensions of DWV Vent Increasers.22I-11Dimensions of DWV Closet Flanges.23I-12Dimensions of DWV Trap Adapters.24I-13Dimensions of DWV Slip-Joint Ends.24ivFOREWORDStandardization of cast and wrought solder-joint fittings was
16、 initiated in Subcommittee 11 of American StandardsAssociation(ASA)SectionalCommittee A40onPlumbingRequirementsand Equipment.Developmentworkculminatedin publication of ASA A40.3-1941.In1949,workonthesefittingswastransferredtoSectionalCommitteeB16ofASA,whichestablishedSubcommittee9(nowSubcommitteeJ).ThefirststandarddevelopedwasapprovedasASAB16.18-1950,CastBronzeSolder-JointFittings.A later joint effort of the Copper and Brass Research Association and the Manufacturers Standardization Society of t