1、Designation:D652922Standard Test Method forOperating Performance of Continuous ElectrodeionizationSystems on Feeds from 50 Scm to 1000 S/cm1This standard is issued under the fixed designation D6529;the number immediately following the designation indicates the year oforiginal adoption or,in the case
2、 of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers the determination of the oper-ating characteristics of continuous electrod
3、eionization(CEDI)devices using synthetic feed solutions and is not necessarilyapplicable to natural waters.This test method is a procedureapplicable to solutions with a conductivity range from approxi-mately 50 Scm to 1000 S cm.1.2 This test method covers the determination of operatingcharacteristic
4、s under standard test conditions of CEDI deviceswhere the electrically active transfer media therein is predomi-nantly unregenerated.This results in more rapid achievementof steady state and shorter test time than when performing atest which requires the active media be predominantly regen-erated.1.
5、3 This test method is not necessarily indicative of thefollowing:1.3.1 Long-term performance on feed waters containingfoulants or sparingly soluble solutes,or both,1.3.2 Performance on feeds of brackish water,sea water,orother high-salinity feeds,1.3.3 Performance on synthetic industrial feed soluti
6、ons,pharmaceuticals,or process solutions of foods and beverages,or,1.3.4 Performance on feed waters less than 50 S cm,particularly performance relating to organic solutes,colloidalor particulate matter,or biological or microbial matter.1.4 This test method,subject to the limitations previouslydescri
7、bed,can be applied as either an aid to predict expecteddeionization performance for a given feed water quality,or asa test method to determine whether performance of a givendevice has changed over some period of time.It is ultimately,however,the users responsibility to ensure the validity of thistes
8、t method for their specific applications.1.5 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the us
9、er of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in t
10、he Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D1125 Test Methods for Electrical Conductivity and Resis-tivity of WaterD1129
11、Terminology Relating to WaterD1193 Specification for Reagent WaterD1293 Test Methods for pH of WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD4189 Test Method for Silt Density Index(SDI)of Water3.Terminology3.1 DefinitionsFor definitio
12、ns of other terms used in thistest method,refer to Terminology D1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 cell,nan independently fed ion-depleting chamberformed by two adjacent ion-exchange membranes,or by amembrane and an adjacent electrode.3.2.2 continuous electrodeionization(C
13、EDI)device,nadevice that removes ionized and ionizable species from liquidsusing electrically active media and using an electrical potentialto influence ion transport,where the ionic transport properties1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct respo
14、nsibilities of Subcommittee D19.08 on Membranes and IonExchange Materials.Current edition approved Oct.1,2022.Published November 2022.Originallyapproved in 2000.Last previous edition approved in 2011 as D6529 11,which waswithdrawn in July 2020 and reinstated in October 2022.DOI:10.1520/D6529-22.2For
15、 referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Co
16、nshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1of the active media are a primary sizing parameter.The CEDIdevices typically comprise semipermeable ion-exchange mem-branes and permanently charged