1、Designation:D437820Standard Practice forIn-Service Monitoring of Mineral Turbine Oils for Steam,Gas,and Combined Cycle Turbines1This standard is issued under the fixed designation D4378;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision
2、,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe in-service monitoring of turbine oils has long been recognized by the power-generationindustry as being n
3、ecessary to ensure long,trouble-free operation of turbines.The two main types of stationary turbines used for power generation are steam and gas turbines;theturbines can be used as individual turbines,or can be configured as combine cycle turbines.Combinedcycle turbines are of two types;the first ty
4、pe connects a gas turbine with a steam turbine,with separatelubricant circuits,and the second type mounts a steam and a gas turbine on the same shaft and has acommon lubricant circuit.The lubrication requirements are quite similar but there are importantdifferences in that gas turbine oils are subje
5、cted to significantly higher localized“hot spot”temperatures and water contamination is less likely.Steam turbine oils are normally expected to lastfor many years.In some turbines up to 20 years of service life has been obtained.Gas turbine oils,bycomparison,have a shorter service life from 2 to 5 y
6、ears depending on severity of the operatingconditions.One of the benefits of the gas turbine is the ability to respond quickly to electrical powergeneration dispatching requirements.Consequently,a growing percentage of modern gas turbines arebeing used for peaking or cyclic duty(frequent unit stops
7、and starts)that subjects the lubricant tovariable conditions(very high down to ambient temperatures),which put additional stresses on thelubricant.This practice is designed to assist the user to validate the condition of the lubricant through its lifecycle by carrying out a meaningful program of sam
8、pling and testing of oils in service.This practiceis performed in order to collect data and monitor trends which suggest any signs of lubricantdeterioration and to ensure a safe,reliable,and cost-effective operation of the monitored plantequipment.1.Scope*1.1 This practice covers the requirements fo
9、r the effectivemonitoring of mineral turbine oils in service in steam and gasturbines,as individual or combined cycle turbines,used forpower generation.This practice includes sampling and testingschedules to validate the condition of the lubricant through itslife cycle and by ensuring required impro
10、vements to bring thepresent condition of the lubricant within the acceptable targets.This practice is not intended for condition monitoring oflubricants for auxiliary equipment;it is recommended that theappropriate practice be consulted(see Practice D6224).1.2 This standard does not purport to addre
11、ss all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.3 This international standard was developed i
12、n accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 A
13、STM Standards:21This practice is under the jurisdiction of ASTM Committee D02 on PetroleumProducts,Liquid Fuels,and Lubricants and is the direct responsibility of Subcom-mittee D02.C0.01 on Turbine Oil Monitoring,Problems and Systems.Current edition approved May 1,2020.Published June 2020.Originally
14、approved in 1984.Last previous edition approved in 2013 as D4378 13.DOI:10.1520/D4378-20.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary p
15、age onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on st
16、andardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.D92 Test Method for Flash and Fire Points by ClevelandOpen Cup TesterD130 Test Method for Corrosiveness to Copper from Petro-leum Products by Copper Strip TestD445 Test Method for Kinematic Viscosity of Transparentand Opaque Liquids(and Calculation of Dynamic Viscos-ity)D664 Test Method fo