1、Designation:D242619Standard Test Method forButadiene Dimer and Styrene in Butadiene Concentrates byGas Chromatography1This standard is issued under the fixed designation D2426;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year
2、of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope*1.1 This test method covers the determination of butadienedimer(4-vinylcyclohexene-1)and styrene in butadieneconcentrates,b
3、oth recycle and specification grade.1.2 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of
4、 this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.For specific precautionary statements see Sections 6 and 8.1.4 This international standard was developed in accor-dance with internationally reco
5、gnized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D1657 Test Method for De
6、nsity or Relative Density of LightHydrocarbons by Pressure HydrometerD1945 Test Method for Analysis of Natural Gas by GasChromatographyD2593 Test Method for Butadiene Purity and HydrocarbonImpurities by Gas Chromatography2.2 Other Documents:2STP 109A Physical Constants of Hydrocarbons C1to C103.Summ
7、ary of Test Method3.1 The sample is introduced into a gas-liquid partitioncolumn.The components of interest are separated as they aretransported through the column by a carrier gas,and theirpresence in the effluent is detected and recorded as a chromato-gram.Packed columns are used,and either therma
8、l conductiv-ity or ionization detectors are permissible.The quantity of thecomponents of interest present in the sample is determinedfrom the chromatogram by comparing their peak areas orheights with those obtained from a synthetic sample.4.Significance and Use4.1 Butadiene dimer and styrene may be
9、present as impuri-ties in commercial butadiene.This test method is suitable foruse in internal quality control and in establishing productspecifications.5.Apparatus5.1 ChromatographAny chromatograph having either athermal conductivity or flame ionization detector may be used.The detector system shal
10、l have sufficient sensitivity to obtain adeflection of at least 2 mm at a signal-to-noise ratio of at least5:1 for 0.01%by mass of butadiene dimer and styrene underthe operating conditions prescribed in this test method.5.2 RecorderA 0 mV to 1 mV,0 mV to 5 mV,or 0 mV to10 mV recorder with a full-sca
11、le response time of 2 s or less,and with sufficient sensitivity to meet the requirements of 5.1.5.3 ColumnAny column may be used that is capable ofresolving the butadiene dimer and styrene as discrete peaks,quantitatively proportional to concentration and within anelapsed time sufficiently short to
12、be practical.5.4 Liquid Sampling ValveAny liquid sampling valve maybe used that will permit the reproducible introduction of thebutadiene concentrate as a liquid under its vapor pressure orhigher and in a quantity sufficient to meet the sensitivity andresolution requirements in 5.1 and 5.3,respectiv
13、ely.NOTE1Suitable valves are commercially available6.Reagents and Materials6.1 4-vinylcyclohexene-1 and Styrene,for calibration,purityof not less than 99%.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products,Liquid Fuels,and Lubricants and is the direct responsibili
14、ty ofSubcommittee D02.D0.04 on C4 and C5 Hydrocarbons.Current edition approved Dec.1,2019.Published January 2020.Originallyapproved in 1965.Last previous edition approved in 2014 as D2426 93(2014).DOI:10.1520/D2426-19.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM
15、Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA
16、 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.6.2 Carrier GasHelium or hydrogen for use on thermalconductivity detector units;or nitrogen,helium,or argon foruse on ionization detector units.(WarningCompresse