1、Designation:C116606(Reapproved 2016)Standard Test Method forFlame Propagation of Dense and Cellular ElastomericGaskets and Accessories1This standard is issued under the fixed designation C1166;the number immediately following the designation indicates the year oforiginal adoption or,in the case of r
2、evision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers a laboratory procedure fordetermining flame propagation characteristics of a de
3、nse orcellular elastomeric gasket(such as expansion,lock-strip orcompression gasket)or an accessory(such as a setting block,spacer or shim)when exposed to heat and flame,with nosignificance being attached to such matters as fuel contribution,rate of flame spread,smoke developed,or the nature andtemp
4、erature of the products of combustion.1.2 The values stated in SI units are to be regarded as thestandard.The values given in parentheses are provided forinformation purposes only.1.3 This standard should be used to measure and describethe response of materials,products,or assemblies to heat andflam
5、e under controlled conditions and should not be used todescribe or appraise the fire-hazard or fire-risk of materials,products,or assemblies under actual fire conditions.However,results of the test may be used as elements of a fire-hazardassessment or a fire-risk assessment which takes into accounta
6、ll of the factors which are pertinent to an assessment of thefire hazard or fire risk of a particular end use.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety a
7、nd health practices and determine the applica-bility of regulatory limitations prior to use.1.5 The committee with jurisdiction over this standard is notaware of any comparable standards published by other orga-nizations.2.Referenced Documents2.1 ASTM Standards:C717 Terminology of Building Seals and
8、 SealantsC864 Specification for Dense Elastomeric Compression SealGaskets,Setting Blocks,and Spacers3.Terminology3.1 DefinitionsFor definitions of terms used in thisstandard,see Terminology C717.3.2 Definitions of Terms Specific to This Standard:3.2.1 dense material,nmaterial that is free of porosit
9、y,asdescribed in Specification C864.4.Summary of Test Method4.1 In this test method,a specimen 13 by 25 by 460 mm(12by 1 by 18 in.)mounted in a vertical position within the testchamber,is exposed to a gas flame at the lower end for 15 minwith dense materials or 5 min with cellular materials,andventi
10、lated at no more than 18.3 m/min(60 ft/min).The lengthof the flame is measured and provides a numerical value for thepropagation of flame along the specimen.5.Significance and Use5.1 This test method is designed to differentiate the flamepropagation characteristics of dense or cellular elastomericco
11、mpounds used in gaskets,setting blocks,shims,or spacers.It is a small scale test which enables the specifier to exerciseengineering judgment in the selection of materials.5.2 In this test method,the specimens are subjected to aspecific laboratory fire test exposure condition.If different testconditi
12、ons are substituted or the anticipated end-use conditionsare changed,it may not be possible by or from this test methodto predict changes in the performance characteristics.Therefore,the results are valid only for the fire test exposurecondition described in this test method.5.3 If the results obtai
13、ned by this test method are to beconsidered in the total assessment of fire risk,then all pertinentestablished criteria for fire risk assessment developed byASTM Committee E-5 must be included in the consideration.6.Apparatus6.1 The Test Chamber,may be any enclosure that willpermit circulation of ai
14、r past the specimen during burning.Ahood or ventilated spray booth is recommended to remove anynoxious products of combustion,provided the velocity of airpast the specimen does not exceed 18.3 m/min(60 ft/min).NOTE1Air velocities greater than 18.3 m/min(60 ft/min)will have an1This test method is und
15、er the jurisdiction ofASTM Committee C24 on BuildingSeals and Sealants and is the direct responsibility of Subcommittee C24.73 onCompression Seal and Lock Strip Gaskets.Current edition approved July 1,2016.Published July 2016.Originally approvedin 1991.Last previous edition approved in 2011 as C1166
16、 06(2011).DOI:10.1520/C1166-06R16.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 extinguishing effect upon the flame and will present an unrealisticevaluation of the flame propagation of the compound.6.2 Bunsen Burner,with a barrel nominally 9.5 mm(0.38in.)in diameter.6.3 Natural Gas,used for fuel.6.4 Measuring Device,capable of measuring to 0.1 in.7.Sampling and Test Specimens7.1 Sampling:7.1.1 When the finished product does not len