1、Designation:C65415Standard Specification forPorous Concrete Pipe1This standard is issued under the fixed designation C654;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the
2、 year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S.Department of Defense.1.Scope1.1 This specification covers porous nonreinforced concretepipe for use in underdrains.1.2 A
3、complete metric companion to this specification hasbeen developed 654M;therefore,no metric equivalents arepresented in this specification.2.Referenced Documents2.1 ASTM Standards:2C33/C33M Specification for Concrete AggregatesC150/C150M Specification for Portland CementC260/C260M Specification for A
4、ir-Entraining Admixturesfor ConcreteC494/C494M Specification for Chemical Admixtures forConcreteC497 Test Methods for Concrete Pipe,Manhole Sections,orTileC595/C595M Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in Concrete
5、C822 Terminology Relating to Concrete Pipe and RelatedProductsC989/C989M Specification for Slag Cement for Use inConcrete and MortarsC1017/C1017M Specification for Chemical Admixtures forUse in Producing Flowing ConcreteC1116/C1116M Specification for Fiber-Reinforced ConcreteC1602/C1602M Specificati
6、on for Mixing Water Used in theProduction of Hydraulic Cement Concrete3.Terminology3.1 DefinitionsFor definitions of terms relating to concretepipe,see Terminology C822.4.Classification4.1 Pipe manufactured according to this specification shallbe of two classes identified as“Standard-Strength Porous
7、Nonreinforced Concrete Pipe”and“Extra-Strength PorousNonreinforced Concrete Pipe.”5.Basis of Acceptance5.1 The acceptability of the pipe shall be determined by theresults of the strength and porosity or rate of infiltration tests,and by inspection to determine whether the pipe conforms tothis specif
8、ication as to design and freedom from defects.5.2 The pipe shall be acceptable under the strength testswhen they have met the requirements as prescribed in Section10.5.3 Acceptance as to Infiltration PropertiesPipe shall beacceptable under the infiltration test when all test pipe conformto the test
9、requirements as prescribed in Section 10.6.Materials6.1 ConcreteThe concrete shall consist of cementitiousmaterials,mineral aggregates,admixtures,if used,and water.6.2 Cementitious Materials:6.2.1 CementCement shall conform to the requirementsfor portland cement of Specification C150/C150M or shall
10、beportland blast-furnace slag cement,portland-limestone cement,or portland-pozzolan cement conforming to the requirementsof Specification C595/C595M,except that the pozzolan con-stituent in the Type IP portlandpozzolan cement shall be flyash.6.2.2 Fly AshFly ash shall conform to the requirements ofS
11、pecification C618,Class F or Class C.6.2.3 Slag CementSlag cement shall conform to the re-quirements of Grade 100 or 120 of Specification C989/C989M.6.2.4 Allowable Combinations of Cementitious MaterialsThe combination of cementitious materials used in the concreteshall be one of the following:6.2.4
12、.1 Portland cement only,6.2.4.2 Portland blast-furnace slag cement only,6.2.4.3 Portland-pozzolan cement only,6.2.4.4 Portland-limestone cement only,1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.01 onNon-Reinf
13、orced Concrete Sewer,Drain and Irrigation Pipe.Current edition approved Oct.1,2015.Published October 2015.Originallyapproved in 1970.Last previous edition approved in 2011 as C654 11.DOI:10.1520/C0654-15.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Servi
14、ce at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 6.2.4.5 A combination of portland cement or portland
15、-limestone cement and fly ash,6.2.4.6 A combination of portland cement or portland-limestone cement and slag cement,6.2.4.7 A combination of portland cement or portland-limestone cement,fly ash,and slag cement,or6.2.4.8 A combination of portland-pozzolan cement and flyash.6.3 AggregatesAggregates sh
16、all conform to the require-ments of Specification C33/C33M,except that the requirementfor gradation shall not apply.6.4 AdmixturesThe following admixtures and blends areallowable:6.4.1 Air-entraining admixture conforming to SpecificationC260/C260M;6.4.2 Chemical admixture conforming to SpecificationC494/C494M;6.4.3 Chemical admixture for use in producing flowingconcrete conforming to Specification C1017/C1017M;and6.4.4 Chemical admixture or blend approved by the owner.6.5 FibersSynthetic fibers