1、Designation:F124408(Reapproved 2018)An American National StandardStandard Specification forBerths,Marine1This standard is issued under the fixed designation F1244;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revis
2、ion.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This specification covers the construction of marineberths for officers,crew,and passengers.1.2 The values stated in inch-pound units
3、 are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This international standard was developed in accor-dance with internationally recognized principles on standard-ization est
4、ablished in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2A512 Specification for Cold-Drawn Buttweld Carbon SteelMechanical
5、 TubingA1008/A1008M Specification for Steel,Sheet,Cold-Rolled,Carbon,Structural,High-Strength Low-Alloy,High-Strength Low-Alloy with Improved Formability,SolutionHardened,and Bake HardenableF825 Specification for Drawers,Furniture,Marine,SteelF1085 Specification for Mattress and Box Springs for Use
6、inBerths in Marine Vessels2.2 AISC Manual:3AISC Wire and Sheet Metal Gages-Equivalent Thicknessesin Decimals of an Inch,U.S.Standard Gage for Uncoated,Hot and Cold Rolled Sheets3.Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 basethe structure on which the drawer and pansections
7、 are supported and which serves to tie the berth to thedeck.3.1.2 berthan item of fixed or built-in furniture forsleeping,with a base and drawer section below the mattressand box spring pan.3.1.3 berth side railthe berth side that runs from head tofoot of berth.3.1.4 box spring the resilient box-typ
8、e support for themattress covered by fabric.3.1.5 drawer sectionthe section of the berth below the pansection normally designed to contain drawers for stowage oflife preservers and other items.3.1.6 handthe berth may be right hand,left hand,orfinished both sides for use in the middle of the room.Rig
9、hthand is defined as follows:the berth is right hand if the head ofthe berth is on the right hand end when the berth is viewedfrom the front.Left hand is opposite.See Fig.1 and Fig.2 andTable 1 and Table 2 for elevations of left-handed berths.Aberth finished on both sides is not shown,but it is one
10、that isaccessible from either side,has the head of the berth against abulkhead,and is not handed.3.1.7 lee raila guard to inhibit a person from rolling out ofbed because of ship motion.In this specification,the lee rail isa raised pine railing.3.1.8 mattressa fabric-covered,box-type unit containings
11、prings and cushioning material that supports the sleepingsurface.3.1.9 pan sectionthe section of the berth designed tosupport the mattress and box spring.4.Classification4.1 Type IAsingle berth with pipe,side lee rail with a boxspring and mattress pan having inside measurements of 54 in.(1372 mm)wid
12、e by 8012in.(2045 mm)long.(See Fig.1,Table 1,and Note 8 and Note 11 of Fig.1.)4.1.1 Type IABerths conforming generally to the Type Ispecifications but having special requirements as indicated inthe ordering information.1This specification is under the jurisdiction of ASTM Committee F25 on Shipsand M
13、arine Technology and is the direct responsibility of Subcommittee F25.03 onOutfitting and Deck Machinery.Current edition approved April 1,2018.Published May 2018.Originallyapproved 1989.Last previous edition approved in 2013 as F1244 08(2013).DOI:10.1520/F1244-08R18.2For referenced ASTM standards,vi
14、sit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from American Institute of Steel Construction(AISC),130 E.Randolph St.,Suite 2000,Chicag
15、o,IL 60601-6219,http:/www.aisc.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principl
16、es for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 4.2 Type IIA single berth with pipe,side lee rail with abox spring and mattress pan having inside measurements of 39in.(991 mm)wide by 8012in.(2045 mm)long.(See Fig.1,Table 1,and Note 8 and Note 11 of Fig.1.)NOTE1For a description of the drawers,see Specification F825.The minimum stowage capacity of each drawer shall be 1.35 ft3(0.038 m3)(