July 2007 IEC 62055-31(First edition 2005)Electricity metering Payment systems Part 31:Particular requirements Static payment meters for active energy(classes 1 and 2)CORRIGENDUM 1 Page 55 C.8 Dielectric strength Fourth bullet,on page 55:Instead of:“impulse test voltage at 1 kV peak”Read:“impulse test voltage at 2 kV peak”Fifth bullet,on page 55:Instead of:“a.c.test voltage at 2 kV r.m.s.”Read:“a.c.test voltage at 1 kV r.m.s.”