1、Copyrighted material licensed to Stanford University by Thomson Scientific(),downloaded on Oct-05-2010 by Stanford University User.No further reproduction or distribution is permitted.Uncontrolled when printed.REAFFIRMED 2004FOR CURRENT COMMITTEE PERSONNELPLEASE E-MAIL CSasme.orgSupplement 1-1998 to

2、 ASME All2.19.1M-1994 Enameled Cast Iron Plumbing Fixtures(This Supplement was approved as an American National Standard on August 27,1998.)Paragraph 4.2.5 has been revised.The revised paragraph appears below.Figure 1 is a new figure which supercedes Fig.1 of the edition.The new figure appears on th

3、e overleaf.4.2.5 Slip Resistance.The bathing surface of a bathtub shall be treated in such a manner that it shall comply with ASTM F 462.Treatment shall start 2 in.measured from all side and wall radii and 3 in.measured from the centerline of the drain and from the compound comer radii.See Fig.1.Cop

4、yright 0 1998 THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS All Rights Reserved J1194A Copyrighted material licensed to Stanford University by Thomson Scientific(),downloaded on Oct-05-2010 by Stanford University User.No further reproduction or distribution is permitted.Uncontrolled when printed.Cent

5、er Drain Tub 2.0 7,.r 3.0 2.0 3.0 Left or Right Hand Drain Bathtubs 1-Radius Break.-1 2.0 4 Treated Surface 4 1-2.0-Cross-section View FIG.1 SLIP RESISTANCE COVERAGE IN BATHTUB SURFACES Copyrighted material licensed to Stanford University by Thomson Scientific(),downloaded on Oct-05-2010 by Stanford

6、 University User.No further reproduction or distribution is permitted.Uncontrolled when printed.Errata to ASME All2.19.1M-1994 Enameled Cast Iron Plumbing Fixtures The Errata corrections listed below apply to ASME A 1 12.19.1 M-1994,Enameled Cast Iron Plumbing Fixtures.This Errata to the 1994 editio

7、n is being issued in the form of replacement pages.Corrections are incorporated directly into the affected pages.Replace or insert the pages listed.It is also advisable that this cover page be retained for reference.The pages show the corrections given below.The pages not listed are the reverse side

8、s of the listed pages and contain no changes.Page Location Change 25-27 Appendix A Revised in its entirety NOVEMBER 1996 THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS 345 East 47th Street,New York,NY 10017 Copyrighted material licensed to Stanford University by Thomson Scientific(),downloaded on Oct-

9、05-2010 by Stanford University User.No further reproduction or distribution is permitted.Uncontrolled when printed.Copyrighted material licensed to Stanford University by Thomson Scientific(),downloaded on Oct-05-2010 by Stanford University User.No further reproduction or distribution is permitted.U

10、ncontrolled when printed.APPENDIX A-GOVERNMENT REQUIREMENTS(This Appendix is not part of ASME A112.19.1M-1994 and is included for Federal Government use only.)A1 SCOPE This Appendix covers requirements of the Federal Government for the procurement of enameled cast iron plumbing fixtures.A2 APPLICABL

11、E DOCUMENTS The following document,of the issues in effect on date of invitation for bids or request for proposal,forms a part of this Appendix to the extent specified herein.ANSI/ASQC ZI.4-Sampling Procedures and Tables for Inspection by Attributes A3 REQUIREMENTS A3.1 Part or identifying Number(PI

12、N)The plumbing fixtures covered by ASME A 1 12.19.1 M-I994 shall be identified by a PIN.This part number is intended for cataloging and ordering purposes(see para.A6)and not for surface marking on the product.The PIN shall be written as shown:PIN designation A I 12.19.1 M-X-XXXXXXXXX ASME document n

13、umber Fixture designation Part numbers(No entry required for undesignated characters)=A3.1.1 Part Numbers for Bathtub(Fixture(a)First character denotes type.Designation=1)A=Comer bathtub with straight front B=Comer bathtub with extended front C=Recess bathtub with straight front D=Recess bathtub wit

14、h extended front E=Drop-in or Island type(with tiling flange)F=Drop-in or Island type(without tiling flange)(6)Second character denotes location of overflow and drain outlet.I=Left hand 2=Right hand(c)Third character denotes nominal size(inches).Width Straight Extended Size Length Front Front Height

15、 A 54 30 32 14 6 54 32 33 14 C 54 30 32 16 D 54 32 33 16 E 60 30 32 14 F 60 32 33 14 G 60 30 32 16 H 60 32 33 16 J 66 30 32 16 K 66 32 33 16(d)Fourth character denotes rough-in.1=Conventional(through the floor drain)2=Nonconventional(above the floor drain)A=White B=As specified(see para.A6)(e)Fifth

16、character denotes color.A3.1.2 Part Numbers for Lavatory(Fixture(a)First character denotes type.Designation=2)A=Straight-front apron with straight.back B=Shelf-back with apron C=Slab-type D=Flat-rim E=Self-rimming F=Pedestal-mounted I=Required 2=Not required shape.A=19 x 17 Rectangular B=20 x 18 Rectangular C=21 x 18 Rectangular D=21 x 19 Rectangular(b)Second character denotes overflow.(c)Third character denotes nominal size(inches)and ASQC standards are available from the American Society for Q