资源描述

1、ASME MFC-6M-1998MEASUREMENT OFFEUID-ELOW-INPIPES USING VORTEXFLOWMETERSREAFFIRMED 2005FOR CURRENT COMMITTEE PERSONNELPLEASE E-MAIL CSasme.orgAN AMERICAN NATIONAL STANDARDMechanical EngineersThe American Society ofhANot for ReealeThe American Society ofMechanical EngineersANAMERICANNATIONALSTAN DAR D

2、MEASUREMENT OFFLUID FLOW INPIPES USING VORTEXFLOWMETERSASME MFC-6M-1998e ith ASMENo reproduction or networking pormittod withou icense from HSNot for ResaloDate of Issuance:July 4,1998This Standard will be revised when the Society approves the issuance ofa new edition.There will be no addenda or wri

3、tten interpretations of therequirements of this Standard issued to this edition.ASME is the registered trademark of The American Society of Mechanical Engineers.This code or standard was developed under procedures accredited as meeting the criteria forAmerican National Standards.The Standards Commit

4、tee that approved the code or standardwas balanced to assure that individuals from competent and concerned interests have had anopportunity to participate.The proposed code or standard was made available for public reviewand comment which provides an opportunity for additional public input from indu

5、stry,academia,regulatory agencies,and the public-at-large.ASME does not approve,rate,or endorseany item,construction,proprietary device,or activity.ASME does not take any position with respect to the validity of any patent rights asserted inconnection with any items mentioned in this document,and do

6、es not undertake to insure anyoneutilizing a standard against liability for infringement of any applicable Letters Patent,nor assumeany such liability.Users of a code or standard are expressly advised that determination of thevalidity of any such patent rights,and the risk of the infringement of suc

7、h rights,is entirely theirown responsibility.Participation by federal agency representative(s)or person(s)affiliated with industry is not tobe interpreted as government or industry endorsement of this code or standard.ASME accepts responsibility for only those interpretations issued in accordance wi

8、th governingASME procedures and policies which preclude the issuance of interpretations by individualvolunteers.No part of this document may be reproduced in any form,in an electronic retrieval system or otherwise,without the prior written permission of the publisher.The American Society of Mechanic

9、al EngineersThree Park Avenue,New York,NY 10016-5990Copyright 1998 byTHE AMERICAN SOCIETY OF MECHANICAL ENGINEERSAll Rights ReservedPrinted in U.S.A.by IHSowh ASMENo reproduction or networking permittod without license from IHSNot for ResaleFOREWORD(This Foreword is not a part of ASME MFC-6M-1998.)T

10、his Standard has been prepared by ASME/MFCC/SC16-Vortex Shedding Flowmeters.It is one of a series of standards covering a variety of devices that measure the.flowof fluids in closed conduits.The vortex shedding principle has become an accepted basis for fluid flow measurement.Meters based on this pr

11、inciple are available for measuring the flow of fluids ranging fromcryogenic liquids to steam and high-pressure gases.Vortex shedding flowmeters are alsoreferred to as vortex meters.Their designs are proprietary and,therefore,their design detailsand associated uncertainty bands cannot be covered in

12、this document.However,these deviceshave in common the shedding of alternating pairs of vortices from some obstruction in themeter.The natural laws of physics relate the shedding frequency,f,to the volumetricflowrate,q.of the fluid in the conduit.The vortex pairs can be counted over a givenperiod of

13、time to obtain total flow.This Standard contains the relevant terminology,test procedures,list of specifications,application notes,and equations with which to determine the expected performance character-istics.This Standard was approved by the American National Standards Institute on February20、199

14、8.公Copyright ASME InternationalNot for ResaleASME STANDARDS COMMITTEE MFFCCMeasurement of Fluid Flow in Closed Conduits(The following is the roster of the Committee at the time of approval of this Standard.)OFFICERSR.W.Miller,ChairE.H.Jones,Vice ChairK.M.Padilla,SecretaryCOMMITTEE PERSONNELN.A.Alsto

15、n,Measurement Control,Inc.C.J.Blechinger,Ford Motor Co.R.W.Caron,Ford Motor Co.G.P.Corpron,Equimeter,Inc.R.J.DeBoom,Micro Motion,Inc.R.H.Fritz,Saudi AramcoT.L.Hillburn,Turnbow EngineeringZ.D.Husain,Texaco,Inc.E.H.Jones,Chevron Petroleum TechnologyT.M.Kegel,Colorado Engineering Experiment Station,Inc

16、.D.R.Keyser,NAWCC.G.Langford,ConsultantJ.Mahieu,Kansas City,Missouri Water Pollution Control DepartmentW.M.Mattar,Foxboro Co.G.E.Mattingly,U.S.Department of CommerceM.P.McHale,McHale Associates,Inc.R.W.Miller,R.W.Miller AssociatesJ.W.Nelson,ConsultantW.F.Seidl,Colorado Engineering Experiment Station

17、,Inc.P.Skweres,Dow ChemicalD.W.Spitzer,Nepera Inc.D.H.Strobel,Badger Meter,Inc.S.H.Taha,Preso IndustriesS.A.Ullrich,Barnant Co.J.H.Vignos,Foxboro Co.D.E.Wiklund,Rosemount,Inc.I.Williamson,Nova Research Technology Corp.D.C.Wyatt,Primary Flow Signal,Inc.SUBCOMMITTEE 16 PERSONNELW.M.Mattar,Chair,Foxbor

18、o Co.G.P.Corpron,Equimeter,Inc.R.J.DeBoom,Micro Motion,Inc.T.M.Kegel,Colorado Engineering Experiment Station,Inc.G.E.Mattingly,U.S.Department of CommerceP.Skweres,Dow ChemicalD.W.Spitzer,Nepera Inc.J.A.Storer,Vortek InstrumentsJ.H.Vignos,Foxboro Co.D.E.Wiklund,Rosemount,Inc.o w ASMENo reproduction or networking permitted without license from IHSNot for Resale