1、AN AMERICAN NATIO NAL STANDARDIntegrated Gasification CombinedCycle Power Generation PlantsASME PTC 47-2006Performance Test CodesCopyrighted material licensed to Stanford University by Thomson Scientific(),downloaded on Oct-05-2010 by Stanford University User.No further reproduction or distribution
2、is permitted.Uncontrolled when printed.ASME PTC 47-2006IntegratedGasificationCombinedCycle PowerGenerationPlantsPerformance Test CodesAN AMERICAN NATIONAL STANDARDThree Park Avenue New York,NY 10016Copyrighted material licensed to Stanford University by Thomson Scientific(),downloaded on Oct-05-2010
3、 by Stanford University User.No further reproduction or distribution is permitted.Uncontrolled when printed.Date of Issuance:January 22,2007This Code will be revised when the Society approves the issuance of a new edition.There will be noaddenda issued to ASME PTC 47-2006.ASME issues written replies
4、 to inquiries as code cases and interpretations of technical aspects ofthis document.Code cases and interpretations are published on the ASME website under theCommittee Pages at http:/cstools.asme.org as they are issued.ASME is the registered trademark of The American Society of Mechanical Engineers
5、.This code or standard was developed under procedures accredited as meeting the criteria for American NationalStandards.The Standards Committee that approved the code or standard was balanced to assure that individuals fromcompetent and concerned interests have had an opportunity to participate.The
6、proposed code or standard was madeavailable forpublic review andcomment thatprovides an opportunityfor additional publicinput from industry,academia,regulatory agencies,and the public-at-large.ASME does not“approve,”“rate,”or“endorse”any item,construction,proprietary device,or activity.ASME does not
7、 take any position with respect to the validity of any patent rights asserted in connection with anyitems mentioned in this document,and does not undertake to insure anyone utilizing a standard against liability forinfringement of any applicable letters patent,nor assumes any such liability.Users of
8、 a code or standard are expresslyadvised that determination of the validity of any such patent rights,and the risk of infringement of such rights,isentirely their own responsibility.Participation by federal agency representative(s)or person(s)affiliated with industry is not to be interpreted asgover
9、nment or industry endorsement of this code or standard.ASME accepts responsibility for only those interpretations of this document issued in accordance with the establishedASME procedures and policies,which precludes the issuance of interpretations by individuals.No part of this document may be repr
10、oduced in any form,in an electronic retrieval system or otherwise,without the prior written permission of the publisher.The American Society of Mechanical EngineersThree Park Avenue,New York,NY 10016-5990Copyright 2007 byTHE AMERICAN SOCIETY OF MECHANICAL ENGINEERSAll rights reservedPrinted in U.S.A
11、.Copyrighted material licensed to Stanford University by Thomson Scientific(),downloaded on Oct-05-2010 by Stanford University User.No further reproduction or distribution is permitted.Uncontrolled when printed.CONTENTSNotice.vForeword.viCommittee Roster.viiCorrespondence With the PTC 47 Committee.i
12、xIntroduction.xSection 1Object and Scope.11-1Object.11-2Scope.11-3Uncertainty.1Section 2Definitions and Descriptions of Terms.32-1Definitions.32-2Symbols Used in Equations.102-3Subscripts Used in Equations.10Section 3Guiding Principles.113-1Introduction.113-2Test Boundary and Required Measurements.1
13、13-3Test Plan.133-4Test Preparations.133-5Conduct of Test.143-6Calculation and Reporting of Results.16Section 4Instruments and Methods of Measurement.174-1General Requirements.174-2Pressure Measurement.174-3Temperature Measurement.184-4Solids Flow Measurement.244-5Liquid Flow Measurement.284-6Gaseou
14、s Flow Measurement.314-7Material Analysis.334-8Input and Output Heat Measurement.334-9Electrical Generation Measurement.344-10Collection and Handling.42Section 5Calculations and Results.445-1Test Result Equations.445-2Calculated(Derived)Terms.485-3Measured Terms.505-4Corrections.51Section 6Report of
15、 Results.566-1General Requirements.566-2Executive Summary.566-3Introduction.566-4Calculations and Results.566-5Instrumentation.566-6Conclusions.576-7Appendices.57iiiCopyrighted material licensed to Stanford University by Thomson Scientific(),downloaded on Oct-05-2010 by Stanford University User.No f
16、urther reproduction or distribution is permitted.Uncontrolled when printed.Figures3-2.2-1IGCC Plants With Air Separation Unit.123-2.2-2IGCC Plants Without Air Separation Unit(Air-Blown,or Oxygen-BlownWith Separate ASU).124-3.1.3-1Four-Wire RTDs.194-3.1.3-2Three-Wire RTDs.194-3.3.2Flow-Through Well.204-3.3.3.1Sampling Grids for Rectangular Ducts.224-3.3.3.2Sampling Grid for Circular Ducts.234-9.1.1Three-Wire Metering Systems.364-9.1.2Four-Wire Metering Systems:Connections for Three Wattmeters or