收藏 分享(赏)

ASTM_E_1396_-_90_2011.pdf

上传人:益****师 文档编号:168632 上传时间:2023-03-04 格式:PDF 页数:4 大小:123.66KB
下载 相关 举报
ASTM_E_1396_-_90_2011.pdf_第1页
第1页 / 共4页
ASTM_E_1396_-_90_2011.pdf_第2页
第2页 / 共4页
ASTM_E_1396_-_90_2011.pdf_第3页
第3页 / 共4页
ASTM_E_1396_-_90_2011.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:E139690(Reapproved 2011)Standard Test Method forSensory Evaluation of Oleoresin Capsicum1This standard is issued under the fixed designation E1396;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.

2、A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method describes standardized procedures forthe sensory evaluation of heat in oleoresin capsicums rangingfrom 100 000 to 1 000

3、000 Scoville heat units(S.H.U.).1.2 This test method is intended as an alternative to theScoville heat test,but results can be expressed in Scoville heatunits(see ASTA Method 21.0 and ISO 3513).1.3 This test method does not apply for ground red pepper,low heat chili peppers,or chili powder.1.4 The v

4、alues stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safe

5、ty and health practices and determine the applica-bility of regulatory limitations prior to use.Specific precau-tionary statements are given in Section 8.2.Referenced Documents2.1 ASTM Standards:E1083 Test Method for Sensory Evaluation of Red PepperHeat22.2 ASTA Standard:ASTA Method 21.0 Official An

6、alytical Methods32.3 ISO Standard:ISO 3513-1977(E),Spices and Condiments-Chilies-Determination of Scoville Index42.4 AOAC Method:Official Methods ofAssociation of OfficialAnalytical Chem-ists International(1996)995.03(43.1.43)3.Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 appr

7、oaching strong heatN-vanillyl-n-nonamide,1.30 ppm.This is 13.0 cm on the 15-cm line scale.It is unusualto see an oleoresin stronger than this.But in the event that apepper with more than expected heat is tested,there remainsthe last 2 cm on the 15-cm line scale.3.1.2 moderate heatN-vanillyl-n-nonami

8、de,0.80 ppm.This is a“moderate”amount of pepper heat.It reads 10 cm onthe 15-cm line scale.3.1.3 rinseto purge the oral cavity with unsalted sodacrackers and 20C spring or distilled water by slowly chewingand swallowing the cracker,followed by swirling the wateraround in the mouth and swallowing.Thi

9、s procedure isrepeated as often as is natural and comfortable for the panelist.3.1.4 Scoville heat units(S.H.U.)the commonly acceptedunit for expressing heat levels in capsicum products(see TestMethod E1083 and ASTA Method 21.0).Scoville heat unitsrange from 0 to 1 500 000.3.1.5 slight heatN-vanilly

10、l-n-nonamide,0.40 ppm.This isa“slight”amount of pepper heat.It reads 5 cm on the 15-cmline scale.3.1.6 strong heatbest defined by concept.Hotter than the1.30-ppm N-vanillyl-n-nonamide sample.It reads 15 cm on the15-cm line scale.3.1.7 threshold heatbest defined by concept rather than bya standard di

11、lution of N-vanillyl-n-nonamide.Threshold is thatpoint where a panelist just barely senses burn/heat.It reads1.25 cm on the 15-cm line scale.3.1.8 zero heatN-vanillyl-n-nonamide,0 ppm.No sensoryheat.It reads 0 cm on the line scale.4.Summary of Test Method4.1 Oleoresin capsicum is steeped in hot wate

12、r withpolysorbate-80 or polysorbate-60 for 3 min,filtered,and thefiltrate diluted in room temperature water.Trained panelists1This test method is under the jurisdiction ofASTM Committee E18 on SensoryEvaluation and is the direct responsibility of Subcommittee E18.06 on Food andBeverage Evaluation.Cu

13、rrent edition approved March 1,2011.Published June 2011.Originallyapproved in 1990.Last previous edition approved in 2004 as E1396 90(2004).DOI:10.1520/E1396-90R11.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of

14、 ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from American Spice Trade Association,Box 1267,EnglewoodCliffs,NJ 07632.4Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.or

15、g.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 compare the heat in the pepper extract to a known concentra-tion of a standard solution of synthetic capsaicin(N-vanillyl-n-nonamide)using a 15-cm line scale.The tasting procedure istimed

16、and takes 2 min for one test sample and 9 min for twotest samples.5This test method is a minor variation on theground red pepper sensory method.4.2 Panelists are screened for their accuracy and precisionand trained to use the 15-cm line scale during two to three15-min training sessions.4.3 Standard general requirements for sensory testing fol-lows.45.Significance and Use5.1 This test method provides quick and accurate ratings forthe sensory heat in oleoresin capsicums ranging from 100 000to 1 00

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2