收藏 分享(赏)

ASTM_E_1164_-_12.pdf

上传人:益****师 文档编号:168786 上传时间:2023-03-04 格式:PDF 页数:9 大小:142.78KB
下载 相关 举报
ASTM_E_1164_-_12.pdf_第1页
第1页 / 共9页
ASTM_E_1164_-_12.pdf_第2页
第2页 / 共9页
ASTM_E_1164_-_12.pdf_第3页
第3页 / 共9页
ASTM_E_1164_-_12.pdf_第4页
第4页 / 共9页
ASTM_E_1164_-_12.pdf_第5页
第5页 / 共9页
ASTM_E_1164_-_12.pdf_第6页
第6页 / 共9页
亲,该文档总共9页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:E116412Standard Practice forObtaining Spectrometric Data for Object-Color Evaluation1This standard is issued under the fixed designation E1164;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A nu

2、mber in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe fundamental procedure for evaluating the color of a reflecting or transmitting object is to obtainspectrometric data for specified illum

3、inating and viewing conditions,and from these data to computetristimulus values based on a CIE(International Commission on Illumination)standard observer anda CIE standard illuminant.The considerations involved and the procedures used to obtain precisespectrometric data are contained in this practic

4、e.The values and procedures for computing CIEtristimulus values from spectrometric data are contained in Practice E308.Considerations regardingthe selection of appropriate illuminating and viewing geometries are contained in Guide E179.1.Scope1.1 This practice covers the instrumental measurementrequ

5、irements,calibration procedures,and material standardsneeded to obtain precise spectral data for computing the colorsof objects.1.2 This practice lists the parameters that must be specifiedwhen spectrometric measurements are required in specificmethods,practices,or specifications.1.3 Mostsectionsoft

6、hispracticeapplytobothspectrometers,which can produce spectral data as output,andspectrocolorimeters,which are similar in principle but canproduce only colorimetric data as output.Exceptions to thisapplicability are noted.1.4 This practice is limited in scope to spectrometers andspectrometric colori

7、meters that employ only a single mono-chromator.This practice is general as to the materials to becharacterized for color.1.5 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.6 This standard does not purport to address the safet

8、yconcerns,if any,associated with its use.It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D1003 Test Method for Haze and Luminous Tr

9、ansmittanceof Transparent PlasticsE179 Guide for Selection of Geometric Conditions forMeasurement of Reflection and Transmission Propertiesof MaterialsE259 Practice for Preparation of Pressed Powder WhiteReflectance Factor Transfer Standards for Hemisphericaland Bi-Directional GeometriesE275 Practic

10、e for Describing and Measuring Performance ofUltraviolet and Visible SpectrophotometersE284 Terminology of AppearanceE308 Practice for Computing the Colors of Objects by Usingthe CIE SystemE387 Test Method for Estimating Stray Radiant Power Ratioof Dispersive Spectrophotometers by the Opaque FilterM

11、ethodE805 Practice for Identification of Instrumental Methods ofColor or Color-Difference Measurement of MaterialsE925 Practice for Monitoring the Calibration of Ultraviolet-Visible Spectrophotometers whose Spectral Bandwidthdoes not Exceed 2 nmE958 Practice for Measuring Practical Spectral Bandwidt

12、hof Ultraviolet-Visible SpectrophotometersE991 Practice for Color Measurement of Fluorescent Speci-mens Using the One-Monochromator Method1This practice is under the jurisdiction of ASTM Committee E12 on Color andAppearance and is the direct responsibility of Subcommittee E12.02 on Spectro-photometr

13、y and Colorimetry.Current edition approved July 1,2012.Published August 2012.Originallyapproved in 1987.Last previous edition approved in 2009 as E1164 09a DOI:10.1520/E1164-122For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For An

14、nual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 E1767 Practice for Specifying the Geometries of Observa-tion and Measurement to

15、Characterize the Appearance ofMaterialsE2153 Practice for Obtaining Bispectral Photometric Datafor Evaluation of Fluorescent ColorE2194 Practice for Multiangle Color Measurement of MetalFlake Pigmented Materials2.2 NIST Publications:LC-1017 Standards for Checking the Calibration of Spectro-photomete

16、rs3TN-594-12 Optical Radiation Measurements:The Translu-cent Blurring EffectMethod of Evaluation and Estima-tion3SP-260-66 Didymium Glass Filters for Calibrating theWavelength Scale of SpectrophotometersSRM 2009,2010,2013,and 20143SP-692 Transmittance MAP Service32.3 CIE Publications:CIE No.15.2 Colorimetry,2nd edition4CIE No.38 Radiometric and Photometric Characteristics ofMaterials and Their Measurement4CIE No.46 Review of Publications on Properties andReflection Values of Material Reflection

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2