1、Designation:E121916Standard Practice forFluorescent Liquid Penetrant Testing Using the Solvent-Removable Process1This standard is issued under the fixed designation E1219;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of la
2、st revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice2covers procedures for fluorescent pen-etrant examination utilizing the solvent-removable process.Itis a nondest
3、ructive testing method for detecting discontinuitiesthat are open to the surface,such as cracks,seams,laps,coldshuts,laminations,isolated porosity,through leaks,or lack offusion and is applicable to in-process,final,and maintenanceexamination.It can be effectively used in the examination ofnonporous
4、,metallic materials,both ferrous and nonferrous,and of nonmetallic materials such as glazed or fully densifiedceramics and certain nonporous plastics and glass.1.2 This practice also provides a reference:1.2.1 By which a fluorescent penetrant examination solvent-removable process recommended or requ
5、ired by individualorganizations can be reviewed to ascertain its applicability andcompleteness.1.2.2 For use in the preparation of process specificationsdealing with the fluorescent solvent-removable liquid penetrantexamination of materials and parts.Agreement by the pur-chaser and the manufacturer
6、regarding specific techniques isstrongly recommended.1.2.3 For use in the organization of the facilities andpersonnel concerned with the liquid penetrant examination.1.3 This practice does not indicate or suggest standards forevaluation of the indications obtained.It should be pointed out,however,th
7、at indications must be interpreted or classified andthen evaluated.For this purpose there must be a separate codeor specification or a specific agreement to define the type,size,location,and direction of indications considered acceptable,and those considered unacceptable.1.4 All areas of this docume
8、nt may be open to agreementbetween the cognizant engineering organization and thesupplier,or specific direction from the cognizant engineeringorganization.1.5 The values stated in inch-pound units are regarded asstandard.SI units given in parentheses are for information only.1.6 This standard does n
9、ot purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:3
10、D129 Test Method for Sulfur in Petroleum Products(Gen-eral High Pressure Decomposition Device Method)D516 Test Method for Sulfate Ion in WaterD808 Test Method for Chlorine in New and Used PetroleumProducts(High Pressure Decomposition Device Method)D1552 Test Method for Sulfur in Petroleum Products b
11、yHigh Temperature Combustion and IR DetectionE165/E165M Practice for Liquid Penetrant Examination forGeneral IndustryE433 Reference Photographs for Liquid Penetrant Inspec-tionE543 Specification for Agencies Performing NondestructiveTestingE1316 Terminology for Nondestructive ExaminationsE2297 Guide
12、 for Use of UV-Aand Visible Light Sources andMeters used in the Liquid Penetrant and Magnetic ParticleMethodsE3022 Practice for Measurement of Emission Characteris-tics and Requirements for LED UV-A Lamps Used inFluorescent Penetrant and Magnetic Particle Testing2.2 ASNT Documents:Recommended Practi
13、ce SNT-TC-1A Personnel Qualifica-tion and Certification in Nondestructive Testing4ANSI/ASNT-CP-189 Qualification and Certification of NDTPersonnel41This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.03 on Liqu
14、idPenetrant and Magnetic Particle Methods.Current edition approved July 1,2016.Published July 2016.Originally approvedin 1987.Last previous edition approved in 2010 as E1219-10.DOI:10.1520/E1219-16.2For ASME Boiler and Pressure Vessel Code applications see related TestMethod SE-1219 in Section II of
15、 that Code.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.4Available from TheAmerican Society for Nondestructive
16、Testing(ASNT),P.O.Box 28518,1711 Arlingate Lane,Columbus,OH 43228-0518.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 2.3 ISO Standard:5ISO 9712 Nondestructive TestingQualification and Certi-fication of NDT PersonnelGeneral Principles2.4 AIA Standard:NAS 410 Certification and Qualification of NondestructiveTest Personnel62.5 Department of Defense(DoD)ContractsUnless oth-erwise specified,the issue of the documents that are DoDadopted