收藏 分享(赏)

ASTM_E_1232_-_07_2019.pdf

上传人:益****师 文档编号:168846 上传时间:2023-03-04 格式:PDF 页数:11 大小:199.87KB
下载 相关 举报
ASTM_E_1232_-_07_2019.pdf_第1页
第1页 / 共11页
ASTM_E_1232_-_07_2019.pdf_第2页
第2页 / 共11页
ASTM_E_1232_-_07_2019.pdf_第3页
第3页 / 共11页
ASTM_E_1232_-_07_2019.pdf_第4页
第4页 / 共11页
ASTM_E_1232_-_07_2019.pdf_第5页
第5页 / 共11页
ASTM_E_1232_-_07_2019.pdf_第6页
第6页 / 共11页
亲,该文档总共11页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:E123207(Reapproved 2019)Standard Test Method forTemperature Limit of Flammability of Chemicals1This standard is issued under the fixed designation E1232;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last rev

2、ision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe temperature limit of flammability test measures the minimum temperature at which liquid(orsolid)chemicals evolve sufficient va

3、pors to form a flammable mixture with air under equilibriumconditions.This temperature is applicable for assessing flammability in large process vessels andsimilar equipment(Appendix X1 and Appendix X2).1.Scope1.1 This test method covers the determination of the mini-mum temperature at which vapors

4、in equilibrium with a liquid(or solid)chemical will be sufficiently concentrated to formflammable mixtures in air at atmospheric pressure.This testmethod is written specifically for determination of the tempera-ture limit of flammability of systems using air as the source ofoxidant and diluent.It ma

5、y also be used for other oxidant/diluent combinations,including air plus diluent mixtures;however,no oxidant/diluent combination stronger than airshould be used.Also,no unstable chemical capable of explo-sive decomposition reactions should be tested(see 8.3).1.2 This test method is designed and writ

6、ten to be run atlocal ambient pressure and is limited to a maximum initialpressure of 1 atm abs.It may also be used for reduced pressureswith the practical lower pressure limit being approximately13.3 kPa(100 mm Hg).The maximum practical operatingtemperature of this equipment is approximately 150C(3

7、02F)(Note A1.2).1.3 The values stated in SI units are to be regarded asstandard.The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.4 This standard should be used to measure and describethe properti

8、es of materials,products,or assemblies in responseto heat and flame under controlled laboratory conditions,andshould not be used to describe or appraise the fire hazard or firerisk of materials,products,or assemblies under actual fireconditions.However,results of this test may be used aselements of

9、a fire risk assessment which takes into account allof the factors which are pertinent to an assessment of the firehazard of a particular end use.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard

10、 to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.Specific safety precautions are given in Section 8.1.6 This international standard was developed in accor-dance with internationally recognized principles on s

11、tandard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D3278 Test Methods for Flash Point of Liquids

12、by SmallScale Closed-Cup ApparatusD3828 Test Methods for Flash Point by Small Scale ClosedCup TesterD3941 Test Method for Flash Point by the EquilibriumMethod With a Closed-Cup ApparatusE220 Test Method for Calibration of Thermocouples ByComparison TechniquesE230 Specification for Temperature-Electr

13、omotive Force(emf)Tables for Standardized ThermocouplesE502 Test Method for Selection and Use of ASTM Stan-dards for the Determination of Flash Point of Chemicalsby Closed Cup Methods1This test method is under the jurisdiction of ASTM Committee E27 on HazardPotential of Chemicals and is the direct r

14、esponsibility of Subcommittee E27.04 onFlammability and Ignitability of Chemicals.Current edition approved Feb.1,2019.Published March 2019.Originallyapproved in 1991.Last previous edition approved in 2013 as E1232 07(2013).DOI:10.1520/E1232-07R19.2For referenced ASTM standards,visit the ASTM website

15、,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis intern

16、ational standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 E537 Test Method for The Thermal Stability of Chemicalsby Differential Scanning CalorimetryE681 Test Method for Concentration Limits of Flammabilityof Chemicals(Vapors and Gases)E698 Test Method

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2