收藏 分享(赏)

ASTM_E_1662_-_95a_2012.pdf

上传人:益****师 文档编号:169677 上传时间:2023-03-04 格式:PDF 页数:12 大小:586.32KB
下载 相关 举报
ASTM_E_1662_-_95a_2012.pdf_第1页
第1页 / 共12页
ASTM_E_1662_-_95a_2012.pdf_第2页
第2页 / 共12页
ASTM_E_1662_-_95a_2012.pdf_第3页
第3页 / 共12页
ASTM_E_1662_-_95a_2012.pdf_第4页
第4页 / 共12页
ASTM_E_1662_-_95a_2012.pdf_第5页
第5页 / 共12页
ASTM_E_1662_-_95a_2012.pdf_第6页
第6页 / 共12页
亲,该文档总共12页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:E166295a(Reapproved 2012)An American National StandardStandard Classification forServiceability of an Office Facility for Sound and VisualEnvironment1,2This standard is issued under the fixed designation E1662;the number immediately following the designation indicates the year oforiginal

2、 adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This classification covers pairs of scales for classifyingan aspect of the

3、 serviceability of an office facility,that is,thecapability of an office facility to meet certain possible require-ments for suitable sound and visual conditions.1.2 Within that aspect of serviceability,each pair of scales,shown in Figs.1-6,are for classifying one topic of serviceabil-ity.Each parag

4、raph in an Occupant Requirement Scale(seeFigs.1-6)summarizes one level of serviceability on that topic,which occupants might require.The matching entry in theFacility Rating Scale(see Figs.1-6)is a translation of therequirement into a description of certain features of a facilitywhich,taken in combi

5、nation,indicate that the facility is likelyto meet that level of required serviceability.1.3 The entries in the Facility Rating Scale(see Figs.1-6)are indicative and not comprehensive.They are for quickscanning to estimate approximately,quickly,and economically,how well an office facility is likely

6、to meet the needs of one oranother type of occupant group over time.The entries are notfor measuring,knowing,or evaluating how an office facility isperforming.1.4 This classification can be used to estimate the level ofserviceability of an existing facility.It can also be used toestimate the service

7、ability of a facility that has been plannedbut not yet built,such as one for which single-line drawingsand outline specifications have been prepared.1.5 This classification indicates what would cause a facilityto be rated at a certain level of serviceability but does not statehow to conduct a servic

8、eability rating nor how to assign aserviceability score.That information is found in PracticeE1334.The scales in this classification are complimentary toand compatible with Practice E1334.Each requires the other.2.Referenced Documents2.1 ASTM Standards:3E631 Terminology of Building ConstructionsE133

9、4 Practice for Rating the Serviceability of a Building orBuilding-Related FacilityE1679 Practice for Setting the Requirements for the Service-ability of a Building or Building-Related Facility2.2 ISO Document:4ISO 6240 International Standard,Performance Standards inBuildingContents and Presentation3

10、.Terminology3.1 Definitions:3.1.1 facilitya physical setting used to serve a specificpurpose.E6313.1.1.1 DiscussionA facility may be within a building,awhole building,or a building with its site and surroundingenvironment;or it may be a construction that is not a building.The term encompasses both t

11、he physical object and its use.3.1.2 facility serviceabilitythe capability of a facility toperform the function(s)for which it is designed,used,orrequired to be used.E6313.1.2.1 DiscussionThe scope of this performance is of thefacility as a system,including its subsystems,components andmaterialsandt

12、heirinteractions,suchasacoustical,hydrothermal,air purity,and economic;and of the relativeimportance of each performance requirement.3.1.3 offcea place,such as a room,suite,or building,inwhich business,clerical,or professional activities areconducted.E6313.1.4 For standard definitions of additional

13、terms applicableto this classification,see Terminology E631.3.2 Definitions of Terms Specific to This Standard:3.2.1 fit-upalterations and improvements to the basebuilding and to the building systems,including demolitionwhere required,to prepare the facility for occupancy.1This classification is und

14、er the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.25on Whole Buildings and Facilities.Current edition approved April 1,2012.Published May 2012.Originallyapproved in 1995.Last previous edition approved in 2005 as E1662 95a(2005).

15、DOI:10.1520/E1662-95AR12.2Portions of this document are based on material originally prepared by theInternational Centre for Facilities(ICF)and 1993 by ICF and Minister of PublicWorks and Government Services Canada.Their cooperation in the development ofthis standard is acknowledged.3For referenced

16、ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.4Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 FIG.1 Scale A.3.1 for Privacy and Speech Intelligib

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2