收藏 分享(赏)

ASTM_E_2446_-_16.pdf

上传人:益****师 文档编号:169834 上传时间:2023-03-04 格式:PDF 页数:14 大小:989.96KB
下载 相关 举报
ASTM_E_2446_-_16.pdf_第1页
第1页 / 共14页
ASTM_E_2446_-_16.pdf_第2页
第2页 / 共14页
ASTM_E_2446_-_16.pdf_第3页
第3页 / 共14页
ASTM_E_2446_-_16.pdf_第4页
第4页 / 共14页
ASTM_E_2446_-_16.pdf_第5页
第5页 / 共14页
ASTM_E_2446_-_16.pdf_第6页
第6页 / 共14页
亲,该文档总共14页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:E244616Standard Practice forManufacturing Characterization of Computed RadiographySystems1This standard is issued under the fixed designation E2446;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision

2、.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice describes the manufacturing characteriza-tion of computed radiography(CR)systems,consisting of aparticular phosphor imagin

3、g plate(IP),scanner,software,andan image display monitor,in combination with specified metalscreens for industrial radiography.1.2 The practice defines system tests to be used to charac-terize the systems of different suppliers and make themcomparable for users.1.3 This practice is intended for use

4、by manufacturers of CRsystems or certification agencies to provide quantitative resultsof CR system characteristics for nondestructive testing(NDT)user or purchaser consumption.Some of these tests requirespecialized test phantoms to ensure consistency of resultsamong suppliers or manufacturers.These

5、 tests are not intendedfor users to complete,nor are they intended for long termstability tracking and lifetime measurements.However,theymay be used for this purpose,if so desired.1.4 The CR system performance is described by the basicspatial resolution,contrast,signal and noise parameters,andthe eq

6、uivalent penetrameter sensitivity(EPS).Some of theseparameters are used to compare with DDAcharacterization andfilm characterization data(see Practice E2597 and Test MethodE1815).NOTE1For film system characterization,the signal is represented bythe optical density of 2(above fog and base)and the noi

7、se as granularity.The signal-to-noise ratio is normalized by the aperture(similar to the basicspatial resolution)of the system and is part of characterization.Thisnormalization is given by the scanning circular aperture of 100 m of themicro-photometer,which is defined in Test Method E1815 for film s

8、ystemcharacterization.1.5 The measurement of CR systems in this practice isrestricted to a selected radiation quality to simplify the proce-dure.The properties of CR systems will change with radiationenergy but not the ranking of CR system performance.Users ofthis practice may carry out the tests at

9、 different or additionalradiation qualities(X-ray or gamma ray)if required.1.6 The values stated in SI are to be regarded as thestandard.1.7 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to esta

10、blish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2E746 Practice for Determining Relative Image Quality Re-sponse of Industrial Radiographic Imaging SystemsE1165 Test Method for Measurement

11、 of Focal Spots ofIndustrial X-Ray Tubes by Pinhole ImagingE1316 Terminology for Nondestructive ExaminationsE1815 Test Method for Classification of Film Systems forIndustrial RadiographyE2002 Practice for Determining Total Image Unsharpnessand Basic Spatial Resolution in Radiography and Radios-copyE

12、2007 Guide for Computed RadiographyE2033 Practice for Computed Radiology(PhotostimulableLuminescence Method)E2445 Practice for Performance Evaluation and Long-TermStability of Computed Radiography SystemsE2597 Practice for Manufacturing Characterization of Digi-tal Detector ArraysE2903 Test Method f

13、or Measurement of the Effective FocalSpot Size of Mini and Micro Focus X-ray Tubes2.2 ISO Standard:3ISO17636-2 Non-DestructiveTestingofWeldsRadiographic TestingPart 2:X-and Gamma Ray Tech-nologies with Digital Detectors1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive

14、 Testing and is the direct responsibility of Subcommittee E07.01 onRadiology(X and Gamma)Method.Current edition approved June 1,2016.Published June 2016.Originallyapproved in 2005.Last previous edition approved in 2015 as E2446 15.DOI:10.1520/E2446-16.2For referenced ASTM standards,visit the ASTM we

15、bsite,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from International Organization for Standardization(ISO),1,ch.dela Voie-Creuse,CP 56,CH-1211 Geneva 20,

16、Switzerland,http:/www.iso.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 3.Terminology3.1 DefinitionsThe definition of terms relating to gamma-and X-radiography,which appear in Terminology E1316,Guide E2007,and Practice E2033,shall apply to the terms usedin this practice.3.2 Definitions of Terms Specific to This Standard:3.2.1 computed radiography system(CR system)A com-plete system of a storage phosphor imaging plate(IP),acorres

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2