1、Designation:D7881201Standard Test Method forDetermination of 4-Carboxybenzaldehyde and p-Toluic Acidin Purified Terephthalic Acid by Capillary Electrophoresiswith Reverse Voltage Mode1This standard is issued under the fixed designation D7881;the number immediately following the designation indicates

2、 the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1NOTEResearch report information in Section 14 was updated editor

3、ially in February 2021.1.Scope*1.1 This test method2covers the determination of4-carboxybenzaldehyde(4-CBA)and p-toluic acid(p-TOL)inpurified terephthalic acid(PTA)by capillary electrophoresis(CE)with reverse voltage mode and UV detection.It isapplicable for 4-CBAfrom 3 to 400 mg/kg and for p-TOLfro

4、m8 to 400 mg/kg,respectively.1.2 In determining the conformance of the test results usingthis method to applicable specification,results shall be roundedoff in accordance with the rounding-off method of PracticeE29.1.3 The values stated in SI units are to be regarded asstandard.No other units of mea

5、surement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of re

6、gulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade

7、Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:3D1193 Specification for Reagent WaterD6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data

8、toDetermine Conformance with SpecificationsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Documents:4EN ISO 8213 Chemical Products for Industrial UseSampling TechniquesSolid Chemical Products in theForm of Particles Varying from Powders to Coa

9、rse Lumps2.3 Other Document:5OSHA Regulations,29 CFR paragraphs 1910.1000 and1910.12003.Terminology3.1 Definitions of Terms Specific to Reverse Voltage Mode inthis Standard:3.1.1 capillary electrophoresis,nan electrophoretic tech-nique in which a sample is introduced into a 50 m to 100 mi.d.fused-si

10、lica capillary filled with electrolyte solution andsubjected to high voltage for separation.3.1.1.1 DiscussionReverse voltage,with the cathode onthe injection side and the anode on the detection side,is appliedacross the capillary causing electrolyte and analytes to migratetowards the anode and thro

11、ugh the capillarys UV detectorwindow.Analytes are separated based upon the differential1This test method is under the jurisdiction of ASTM Committee D16 onAromatic,Industrial,Specialty and Related Chemicals and is the direct responsi-bility of Subcommittee D16.02 on Oxygenated Aromatics.Current edit

12、ion approved Oct.1,2020.Published December 2020.Originallyapproved in 2013.Last previous edition approved in 2019 as D7881 19.DOI:10.1520/D7881-20E01.2This standard is based on SH/T 16872000 Purified terephthalic acid forindustrial usedetermination of 4-Carboxybenzaldehyde and p-Toluic Acid-Highperf

13、ormance capillary electrophoresis(HPCE),copyright SINOPEC,22 Chaoyang-men North Street,Chaoyang District,Beijing,China 100728.A copy of SH/T16872000 may be obtained from China Petrochemical Press,www.sinopec-.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer

14、Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.4Available from Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.5Available from U.S.G

15、overnment Printing Office Superintendent of Documents,732 N.Capitol St.,NW,Mail Stop:SDE,Washington,DC 20401,http:/www.access.gpo.gov.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United

16、 StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1rates of migration in the electrical field.Analyte detection andquantitation are based upon the principles of UV detection.3.1.2 electrolyte,na combination of a buffer reagent,an