收藏 分享(赏)

ASTM_D_8014_-_17.pdf

上传人:益****师 文档编号:170243 上传时间:2023-03-04 格式:PDF 页数:4 大小:142.19KB
下载 相关 举报
ASTM_D_8014_-_17.pdf_第1页
第1页 / 共4页
ASTM_D_8014_-_17.pdf_第2页
第2页 / 共4页
ASTM_D_8014_-_17.pdf_第3页
第3页 / 共4页
ASTM_D_8014_-_17.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:D801417Standard Guide forSelection of Membranes Used in Vegetative RoofingSystems1This standard is issued under the fixed designation D8014;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A numbe

2、r in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 The purpose of this guide is to provide guidance in theselection of a suitable waterproofing membrane within avegetative roof system.The guide o

3、ffers various options forreviewing the membrane installation during and upon comple-tion of the installation and prior to the vegetative componentsbeing installed.This guide applies to membranes that do or donot require UV protection.For the purpose of this guide,thesupporting structure and roof dec

4、k are assumed to be mechani-cally and structurally sound and will accept the weight of thevegetative roof system including the membrane,insulation,andother roofing/waterproofing components including all compo-nents related to the vegetative layers as well as the requireddesign loads.Slope to drain a

5、t the membrane level is preferredand should be included where possible.Providing a replace-ment or a re-cover vegetative roofing system on an existingbuilding may require that the support structure be reinforced sothat it can safely support the additional weight of the vegetativeroof system and also

6、 provide the minimum live load capacityrequired by the building code.1.2 Design criteria associated with the vegetative portionsof the system are beyond the scope of this guide.Please referto Guide E2777.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with i

7、ts use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standar

8、d-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D1079 Terminology Relating to Roofing and Waterproof

9、ingD5957 Guide for Flood Testing Horizontal WaterproofingInstallationsD7877 Guide for Electronic Methods for Detecting andLocating Leaks in Waterproof MembranesE2777 Guide for Vegetative(Green)Roof Systems2.2 ANSI/SPRI Standards:3ANSI/SPRI VR-1 Procedure for Investigating Resistance toRoot Penetrati

10、on on Vegetative Roofs2.3 Other Standards and Documents:FLL Guidelines for the Planning,Construction and Mainte-nance of Green Roofing Green Roofing Guideline Sec-tion 6.3 Protection Against Damage to the Waterproofing/Root-resistant Membranes FLL Procedure for Investigat-ing Resistance to Root Pene

11、tration of Roof Membranesand Protective Layers for Green Roofing43.Terminology3.1 DefinitionsFor definitions of terms used in this guide,see Terminology D1079.4.Significance and Use4.1 Thisguideprovidesthegeneralinformation,procedures,and guidelines for the selection of the waterproof-ing membrane t

12、o create a waterproofing system for a Vegeta-tive(Green)roof.4.2 This guide is not all inclusive;this guide is intended tosupplement detailed instructions from manufacturers,ASTMStandards,and building code requirements.5.Roof Design Classifications5.1 Types of Constructions or Applications:1This gui

13、de is under the jurisdiction of ASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.24 on Sustain-ability.Current edition approved July 15,2017.Published August 2017.DOI:10.1520/D8014-17.2For referenced ASTM standards,visit the ASTM website,www.astm.or

14、g,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.4Available

15、 from Forschungsgesellschaft Landschaftsentwicklung Landschafts-bau e.V.(FLL),Friedensplatz 4,53111 Bonn,Germany,www.fll.de.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with interna

16、tionally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 5.1.1 NewA vegetative roof can be integrated with theother building elements during construction.All new compo-nents are used to construct the roofing/waterproofing system.Performance and service requirements of the vegetated roof areaddressed in the b

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2