收藏 分享(赏)

ASTM_D_7284_-_13.pdf

上传人:益****师 文档编号:171234 上传时间:2023-03-04 格式:PDF 页数:8 大小:140.26KB
下载 相关 举报
ASTM_D_7284_-_13.pdf_第1页
第1页 / 共8页
ASTM_D_7284_-_13.pdf_第2页
第2页 / 共8页
ASTM_D_7284_-_13.pdf_第3页
第3页 / 共8页
ASTM_D_7284_-_13.pdf_第4页
第4页 / 共8页
ASTM_D_7284_-_13.pdf_第5页
第5页 / 共8页
ASTM_D_7284_-_13.pdf_第6页
第6页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:D728413Standard Test Method forTotal Cyanide in Water by Micro Distillation followed byFlow Injection Analysis with Gas Diffusion Separation andAmperometric Detection1This standard is issued under the fixed designation D7284;the number immediately following the designation indicates the

2、year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method is used to determine the concentrationof t

3、otal cyanide in an aqueous wastewater or effluent.Themethod detects the cyanides that are free(HCN and CN-)andstrong-metal-cyanide complexes that dissociate and releasefree cyanide when refluxed under strongly acidic conditions.1.2 This method may not be applicable to process solutionsfrom precious

4、metals mining operations.1.3 This procedure is applicable over a range of approxi-mately 2 to 500 g/L(parts per billion)total cyanide.Higherconcentrations can be measured with sample dilution or lowerinjection volume.1.4 The determinative step of this method utilizes flowinjection with amperometric

5、detection based on Test MethodD6888.Prior to analysis,samples must be distilled with amicro-distillation apparatus described in this test method orwith a suitable cyanide distillation apparatus specified in TestMethods D2036.1.5 The values stated in SI units are to be regarded asstandard.No other un

6、its of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regula

7、tory limitations prior to use.Specific hazardstatements are given in 8.6 and Section 9.2.Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2036 Test Methods for Cyanides in WaterD2777 Practice for Determination of Precision and Bias ofAp

8、plicable Test Methods of Committee D19 on WaterD3856 Guide for Management Systems in LaboratoriesEngaged in Analysis of WaterD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisD6696 Guide for Understanding Cyanide SpeciesD6888 Test Method for Availab

9、le Cyanide with LigandDisplacement and Flow InjectionAnalysis(FIA)UtilizingGas Diffusion Separation and Amperometric DetectionD7365 Practice for Sampling,Preservation and MitigatingInterferences in Water Samples for Analysis of CyanideE691 Practice for Conducting an Interlaboratory Study toDetermine

10、 the Precision of a Test Method3.Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method,referto Terminology D1129 and Guide D6696.3.2 Definitions of Terms Specific to This Standard:3.2.1 total cyanideTotal cyanide is an analytically definedterm that refers to the sum tota

11、l of all of the inorganic chemicalforms of cyanide that dissociate and release free cyanide whenrefluxed under strongly acidic conditions.Total cyanide isdetermined analytically through strong acid distillation or UVradiation followed by analysis of liberated free cyanide onaqueous samples preserved

12、 with NaOH(pH12).In water,total cyanide includes the following dissolved species:freecyanide,weak acid dissociable metal cyanide complexes andstrong metal cyanide complexes.Also,some of the strongmetal cyanide complexes,such as those of gold,cobalt andplatinum,might not be fully recovered during the

13、 total cyanideanalytical procedure.Additionally,total cyanide may alsoinclude some organic forms of cyanide such as nitriles thatrelease free cyanide under the conditions of the analysis.1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Sub

14、committee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved June 15,2013.Published July 2013.Originallyapproved in 2008.Last previous edition approved in 2008 as D7284 081.DOI:10.1520/D7284-13.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orco

15、ntact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 4.Summary of Test Method4.1

16、 The samples are distilled with a strong acid in thepresence of magnesium chloride catalyst and captured insodium hydroxide absorber solution.4.2 The absorber solution is introduced into a flow injectionanalysis(FIA)system where it is acidified to form hydrogencyanide(HCN).The hydrogen cyanide gas diffuses through ahydrophobic gas diffusion membrane,from the acidic donorstream into an alkaline acceptor stream.4.3 The captured cyanide is sent to an amperometric flow-cell detector with a silver-wo