收藏 分享(赏)

ASTM_D_7597_-_16_2017.pdf

上传人:益****师 文档编号:171472 上传时间:2023-03-04 格式:PDF 页数:13 大小:335.87KB
下载 相关 举报
ASTM_D_7597_-_16_2017.pdf_第1页
第1页 / 共13页
ASTM_D_7597_-_16_2017.pdf_第2页
第2页 / 共13页
ASTM_D_7597_-_16_2017.pdf_第3页
第3页 / 共13页
ASTM_D_7597_-_16_2017.pdf_第4页
第4页 / 共13页
ASTM_D_7597_-_16_2017.pdf_第5页
第5页 / 共13页
ASTM_D_7597_-_16_2017.pdf_第6页
第6页 / 共13页
亲,该文档总共13页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:D759716(Reapproved 2017)Standard Test Method forDetermination of Diisopropyl Methylphosphonate,EthylHydrogen Dimethylamidophosphate,EthylMethylphosphonic Acid,Isopropyl Methylphosphonic Acid,Methylphosphonic Acid and Pinacolyl MethylphosphonicAcid in Water by Liquid Chromatography/Tandem

2、 MassSpectrometry1This standard is issued under the fixed designation D7597;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon(

3、)indicates an editorial change since the last revision or reapproval.1.Scope1.1 This procedure covers the determination of diisopropylmethylphosphonate(DIMP),ethyl hydrogen dimethylami-dophosphate(EHDMAP),ethyl methylphosphonic acid(EMPA),isopropyl methylphosphonic acid(IMPA),methyl-phosphonic acid(

4、MPA)and pinacolyl methylphosphonic acid(PMPA)(referred to collectively as organophosphonates in thistest method)in surface water by direct injection using liquidchromatography(LC)and detected with tandem mass spec-trometry(MS/MS)using electrospray ionization(ESI).Theseanalytes are qualitatively and

5、quantitatively determined by thistest method.This test method adheres to single reactionmonitoring(SRM)mass spectrometry.1.2 This test method has been developed by U.S.EPARegion 5 Chicago Regional Laboratory(CRL).1.3 The values stated in SI units are to be regarded asstandard.No other units of measu

6、rement are included in thisstandard.1.4 The detection verification level(DVL)and reportingrange for the organophosphonates are listed in Table 1.1.4.1 The DVL is required to be at a concentration at leastthree times below the reporting limit(RL)and have a signal/noise ratio greater than 3:1.Fig.1 di

7、splays the signal/noiseratios at the DVLs for the organophosphonates in the ESIpositive mode and Fig.2 in the ESI negative mode.1.4.2 The reporting limit is the concentration of the Level 1calibration standard as shown in Table 2 for the organophos-phonates except for MPA in the ESI negative mode wh

8、ich is atLevel 2 due to not meeting the DVL criteria at the lowerconcentration level.The DVL for MPA in the ESI negativemode is at 20 g/L,which forces a raised reporting limit.However,the multi-laboratory validation required a spike of alltarget analytes at Level 1 concentrations.The mean recoveryfo

9、r MPA in the ESI negative mode at this level was 98.7%asshown in Table 3.If your instruments sensitivity can meet therequirements in this test method,MPA may have a 50 g/Lreporting limit.1.5 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is ther

10、esponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization establi

11、shed in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent Wa

12、terD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3856 Guide for Management Systems in LaboratoriesEngaged in Analysis of WaterD3694 Practices for Preparation of Sample Containers andfor Preservation of Organic ConstituentsD5847 Practice fo

13、r Writing Quality Control Specificationsfor Standard Test Methods for Water Analysis1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved June 15

14、,2017.Published July 2017.Originallyapproved in 2009.Last previous edition approved in 2016 as D7597 16.DOI:10.1520/D7597-16R17.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,re

15、fer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established

16、in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 E2554 Practice for Estimating and Monitoring the Uncer-tainty of Test Results of a Test Method Using ControlChart Techniques2.2 Other Documents:3EPA Publication SW-846 Test Methods for Evaluating SolidWaste,Physical/Chemical Methods3.Terminology3.1 Definitions:3.1.1 For definitions of terms used in this standard,

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2