1、Designation:D770617Standard Practice forRapid Screening of VOC Emissions from Products UsingMicro-Scale Chambers1This standard is issued under the fixed designation D7706;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of la

2、st revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice describes a micro-scale chamber apparatusand associated procedures for rapidly screening materials andproducts

3、for their vapor-phase emissions of volatile organiccompounds(VOCs)including formaldehyde and other carbo-nyl compounds.It is intended to complement,not replacereference methods for measuring chemical emissions forexample,small-scale chamber tests(Guide D5116)and emis-sion cell tests(Practice D7143).

4、1.2 This practice is suitable for use in and outside oflaboratories,in manufacturing sites and in field locations withaccess to electrical power.1.3 Compatible material/product types that may be tested inthe micro-scale chamber apparatus include rigid materials,dried or cured paints and coatings,com

5、pressible products,andsmall,irregularly-shaped components such as polymer beads.1.4 This practice describes tests to correlate emission resultsobtained from the micro-scale chamber with results obtainedfrom VOC emission reference methods(for example,GuideD5116,Test Method D6007,Practice D7143,and IS

6、O 16000-9and ISO 16000-10).1.5 The micro-scale chamber apparatus operates at moder-ately elevated temperatures,30C to 60C,to eliminate theneed for cooling,to reduce test times,boost emission rates,andenhance analytical signals for routine emission screening,andto facilitate screening of semi-volatil

7、e VOC(SVOC)emissionssuch as emissions of some phthalate esters and other plasticiz-ers.1.6 Gas sample collection and chemical analysis are depen-dent upon the nature of the VOCs targeted and are beyond thescope of this practice.However,the procedures described inTest Method D7339,Practice D6196 and

8、ISO 16000-6 foranalysis of VOCs and in Test Method D5197 and ISO 16000-3for analysis of formaldehyde and other carbonyl compoundsare applicable to this practice.1.7 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.8 This standar

9、d does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.9 This international standard wa

10、s developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced D

11、ocuments2.1 ASTM Standards:2D1356 Terminology Relating to Sampling and Analysis ofAtmospheresD1914 Practice for Conversion Units and Factors Relating toSampling and Analysis of AtmospheresD5116 Guide for Small-Scale Environmental Chamber De-terminations of Organic Emissions from Indoor Materials/Pro

12、ductsD5197 Test Method for Determination of Formaldehyde andOther Carbonyl Compounds inAir(Active Sampler Meth-odology)D5337 Practice for Flow Rate Adjustment of Personal Sam-pling PumpsD6007 Test Method for Determining Formaldehyde Concen-trations in Air from Wood Products Using a Small-ScaleChambe

13、rD6196 Practice for Choosing Sorbents,Sampling Param-eters and Thermal Desorption Analytical Conditions forMonitoring Volatile Organic Chemicals in AirD7143 Practice for Emission Cells for the Determination ofVolatile Organic Emissions from Indoor Materials/Products1This practice is under the jurisd

14、iction ofASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition approved May 1,2017.Published June 2017.Originallyapproved in 2011.Last previous edition approved in 2011 as D7706 11.DOI:10.1520/D7706-17.2For referenced ASTM standards,vi

15、sit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.Unit

16、ed StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 D7339 Test Method for Determination of Volatile OrganicCompounds Emitted from Carpet using a Specific SorbentTube and Thermal Desorption/Gas Chromatography2.2 ISO Standards:3I