收藏 分享(赏)

ASTM_D_6522_-_11.pdf

上传人:益****师 文档编号:172991 上传时间:2023-03-04 格式:PDF 页数:10 大小:280.31KB
下载 相关 举报
ASTM_D_6522_-_11.pdf_第1页
第1页 / 共10页
ASTM_D_6522_-_11.pdf_第2页
第2页 / 共10页
ASTM_D_6522_-_11.pdf_第3页
第3页 / 共10页
ASTM_D_6522_-_11.pdf_第4页
第4页 / 共10页
ASTM_D_6522_-_11.pdf_第5页
第5页 / 共10页
ASTM_D_6522_-_11.pdf_第6页
第6页 / 共10页
亲,该文档总共10页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:D652211Standard Test Method forDetermination of Nitrogen Oxides,Carbon Monoxide,andOxygen Concentrations in Emissions from Natural Gas-Fired Reciprocating Engines,Combustion Turbines,Boilers,and Process Heaters Using Portable Analyzers1This standard is issued under the fixed designation

2、D6522;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1

3、.Scope1.1 This test method covers the determination of nitrogenoxides(NO and NO2),carbon monoxide(CO),and oxygen(O2)concentrations in controlled and uncontrolled emissionsfrom natural gas-fired reciprocating engines,combustionturbines,boilers,and process heaters using portable analyzerswith electroc

4、hemical sensors.Due to the inherent cross sensi-tivities of the electrochemical cells,this test method should notbe applied to other pollutants or emission sources without acomplete investigation of possible analytical interferences anda comparative evaluation with EPA test methods.1.1.1 The procedu

5、res and specifications of this method wereoriginally developed during laboratory and field tests fundedby the Gas Research Institute(GRI).2Comparative emissiontests were conducted only on natural gas-fired combustionsources.Subsequently,the United States Environmental Pro-tection Agency(EPA)sponsore

6、d Environmental TechnologyVerification(ETV)program conducted further evaluations ofelectrochemical cell analyzers,which included laboratory testsand field tests on natural gas and diesel-fueled generators.TheEPA has reviewed the ETV test results,published additionalinformation,and provided technical

7、 input that has been con-sidered in the update of this method.31.2 This test method contains notes that are explanatory andare not part of the mandatory requirements of the standard.1.3 The values stated in SI units are to be regarded as thestandard.The values given in parentheses are for informatio

8、nonly.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.2.Reference

9、d Documents2.1 ASTM Standards:4D1356 Terminology Relating to Sampling and Analysis ofAtmospheres2.2 EPA Methods from 40 CFR Part 60,Appendix A5Method 3A-Determination of Oxygen and Carbon DioxideConcentrations in Emissions from Stationary Sources(Instrumental Analyzer Procedure)Method 7E-Determinati

10、on of Nitrogen Oxides Emissionsfrom Stationary Sources(Instrumental Analyzer Proce-dure)Method 10-Determination of Carbon Monoxide Emissionsfrom Stationary SourceMethod 20-Determination of Nitrogen Oxides,SulfurDioxide,and Diluent Emissions from Stationary GasTurbines2.3 EPA Methods from 40 CFR Part

11、 63,Appendix A:Method 301 Field Validation of Pollutant MeasurementMethods from Various Waste Media52.4 EPA Methods from 40 CFR Part 75,Appendix H:Revised Traceability Protocol No.1:Protocol G1 and G2Procedures63.Terminology3.1 For terminology relevant to this test method,see Termi-nology D1356.1Thi

12、s test method is under the jurisdiction of ASTM Committee D22 on AirQuality and is the direct responsibility of Subcommittee D22.03 on AmbientAtmospheres and Source Emissions.Current edition approved Dec.1,2011.Published February 2012.Originallyapproved in 2000.Last previous edition approved in 2005

13、 as D6522 00(2005).DOI:10.1520/D6522-11.2Gas Research Institute Topical Report,“Development of an ElectrochemicalCell Emission Analyzer Test Method,”GRI-96/0008,July 1997.3“Evaluation of Portable Analyzers for Use in Quality Assuring PredictiveEmission Monitoring Systems for NOx”EPA Contract No.68-W

14、-03-033,Septem-ber 2004.4For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.5Available from Superintendent of Document

15、s,U.G.Government PrintingOffice,Washington,DC 20402.6EPA-600/R-97/121,EPA Traceability Protocol for Assay and Certification ofGaseous Calibration Standards,September 1997,as amended August 25,1999.Available from:http:/www.epa.gov/ttn/emc/news.html.Copyright ASTM International,100 Barr Harbor Drive,P

16、O Box C700,West Conshohocken,PA 19428-2959.United States1 3.2 Definitions of Terms Specific to This Standard:3.2.1 measurement system,ntotal equipment required forthe determination of gas concentration.The measurementsystem consists of the following major subsystems:3.2.1.1 data recorder,na strip chart recorder,computer,ordigital recorder for recording measurement data.3.2.1.2 electrochemical cell,nthat portion of the systemthat senses the gas to be measured and generates an outputproportional t

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2