1、Designation:D785213(Reapproved 2022)Standard Practice forUse of an Electrically Conductive Geotextile for LeakLocation Surveys1This standard is issued under the fixed designation D7852;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,

2、the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This standard practice describes standard procedures forusing a conductive geotextile with electrical methods t

3、o locateleaks in exposed geomembranes and geomembranes coveredwith water or earth materials containing moisture.1.2 This standard practice provides guidance for the use ofappropriate conductive geotextile used in leak location surveyon geomembrane.This guide includes all types of conductivegeotextil

4、e with sufficient conductivity for the particular elec-trical leak location method.A conductive geotextile is appli-cable to all types of geoelectric surveys when there is otherwisenot a conductive layer under the geomembrane.1.3 The leak stream itself being adequately conductive.Aconductive geotext

5、ile is applicable to all types of geoelectricsurveys when there is otherwise not a conductive layer underthe geomembrane.1.4 This standard practice is intended to ensure that leaklocation surveys can always be performed with a reasonablelevel of certainty.This standard practice provides guidance for

6、the use of appropriate conductive geotextile used in leaklocation survey on geomembranes.1.5 Leak location surveys can be used on nonconductivegeomembranes installed in basins,ponds,tanks,ore and wastepads,landfill cells,landfill caps,other containment facilities,and building applications such as in

7、 parking garages,decks,and green roofs.The procedures are applicable for geomem-branes made of nonconductive materials such as polyethylene,polypropylene,polyvinylchloride,chlorosulfonatedpolyethylene,bituminous material,and other electrically insu-lating materials.Leak location survey involving con

8、ductive orpartially conductive geomembranes are not within the scope ofthis document.1.6 WarningThe electrical methods used for geomem-brane leak location could use high voltages,resulting in thepotential for electrical shock or electrocution.This hazardmight be increased because operations might be

9、 conducted inor near water.In particular,a high voltage could exist betweenthe water or earth material and earth ground,or any groundedconductor.TheseproceduresarepotentiallyVERYDANGEROUS,and can result in personal injury or death.Because of the high voltage that could be involved,and theshock or el

10、ectrocution hazard,do not come in electrical contactwith any leak unless the excitation power supply is turned off.The electrical methods used for geomembrane leak locationshould be attempted only by qualified and experienced person-nel.Appropriate safety measures must be taken to protect theleak lo

11、cation operators as well as other people at the site.1.7 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the appl

12、icability of regulatory limitations prior to use.1.8 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by t

13、he World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D4439 Terminology for GeosyntheticsD6747 Guide for Selection of Techniques for Electrical LeakLocation of Leaks in GeomembranesD7002 Practice for Electrical Leak Location on ExposedGeomembr

14、anes Using the Water Puddle MethodD7007 Practices for Electrical Methods for Locating Leaksin Geomembranes Covered with Water or Earthen Mate-rials3.Terminology3.1 For general definitions related to geosynthetics,seeTerminology D4439.1This practice is under the jurisdiction of ASTM Committee D35 on

15、Geosyn-thetics and is the direct responsibility of Subcommittee D35.10 on Geomembranes.Current edition approved Jan.15,2022.Published January 2022.Originallyapproved in 2013.Last previous edition approved in 2013 as D7852 13.DOI:10.1520/D7852-13R22.2For referenced ASTM standards,visit the ASTM websi

16、te,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Gui