收藏 分享(赏)

ASTM_D_5660_-_96_2009.pdf

上传人:益****师 文档编号:175117 上传时间:2023-03-04 格式:PDF 页数:9 大小:108.14KB
下载 相关 举报
ASTM_D_5660_-_96_2009.pdf_第1页
第1页 / 共9页
ASTM_D_5660_-_96_2009.pdf_第2页
第2页 / 共9页
ASTM_D_5660_-_96_2009.pdf_第3页
第3页 / 共9页
ASTM_D_5660_-_96_2009.pdf_第4页
第4页 / 共9页
ASTM_D_5660_-_96_2009.pdf_第5页
第5页 / 共9页
ASTM_D_5660_-_96_2009.pdf_第6页
第6页 / 共9页
亲,该文档总共9页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:D566096(Reapproved 2009)Standard Test Method forAssessing the Microbial Detoxification of ChemicallyContaminated Water and Soil Using a Toxicity Test with aLuminescent Marine Bacterium1This standard is issued under the fixed designation D5660;the number immediately following the designat

2、ion indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method(1)2covers a procedure fo

3、r the rapidevaluation of the toxicity3of wastewaters and aqueous extractsfrom contaminated soils and sediments,to the luminescentmarine bacterium Photobacterium phosphoreum,4prior to andfollowing biological treatment.This test method is meant foruse as a means to assess samples resulting from biotre

4、atabilitystudies.Sensitivity data for P.phosphoreum to over 1300chemicals have been reported in the literature(2).Some of thepublications are very relevant to this test method(3).The dataobtained from this test method,when combined withrespirometry,total organic carbon(TOC),biochemical oxygendemand(

5、BOD),chemical oxygen demand(COD),or spectro-photometric data,can assist in the determination of the degreeof biodegradability of a contaminant in water,soil,or sediment(3).The percentage difference between the IC20 of treated anduntreated sample is used to assess the progress of detoxifica-tion.1.2

6、This test method is applicable to the evaluation of thetoxicity(to a specific microbe)and its implication on thebiodegradation of aqueous samples from laboratory researchbio-reactors(liquid or soil),pilot-plant biological treatmentsystems,full-scale biological treatment systems,and landapplication p

7、rocesses(see Notes 1 and 2).NOTE1If the biologically treated material is to be discharged in sucha manner as to potentially impact surface waters and ground water,orboth,then the user must consult appropriate regulatory guidance docu-ments to determine the proper test species for evaluating potentia

8、lenvironmental impact(4).Correlations between data concerning reductionin toxicity produced by this test method and by procedures for acute orshort-term chronic toxicity tests,or both,utilizing invertebrates and fish(see Guides E729 and E1192),should be established,wherever possible.NOTE2Color(espec

9、ially red and brown),turbidity,and suspendedsolids interfere with this test method by absorbing or reflecting light.Inthese situations data are corrected for these effects by use of an absorbancecorrection procedure included in this test method(see 5.3,6.1,and 6.2).51.3 The results of this test meth

10、od are reported in terms ofan inhibitory concentration(IC),which is the calculatedconcentration of sample required to produce a specific quanti-tative and qualitative inhibition.The inhibition measured is thequantitative reduction in light output of luminescent marinebacteria(that is,IC20 represents

11、 the calculated concentrationof sample that would produce a 20%reduction in the lightoutput of exposed bacteria over a specified time).1.4 The values stated in SI units are to be regarded as thestandard.The values given in parentheses are for informationonly.1.5 This standard does not purport to add

12、ress all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.Specific hazardstatements are given in Section 9.2.Referenc

13、ed Documents2.1 ASTM Standards:6D888 Test Methods for Dissolved Oxygen in Water1This test method is under the jurisdiction of ASTM Committee D34 on WasteManagement and is the direct responsibility of Subcommittee D34.03 on Treatment,Recovery and Reuse.Current edition approved Sept.1,2009.Published N

14、ovember 2009.Originallyapproved in 1995.Last previous edition approved in 2004 as D5660 96(2004).DOI:10.1520/D5660-96R09.2The boldface numbers in parentheses refer to the list of references at the end ofthis standard.3Toxicity measured as toxic inhibition of bacterial light output.4Microbics Corp.is

15、 currently the only known supplier of the reagents(testorganism Photobacterium phosphoreum strain NRRL B-11177)specific to this testmethod.There are two known manufacturers of analyzers that can be used tomeasure bioluminescence under temperature control:Microbics Corp.,2232 Ru-therford Road,Carlsba

16、d,CA 92008(Microtox Model 500 and Model 2055Analyzers),and Pharmacia LKB,9319 Gaither Road,Gaithersburg,MD 20877(LKB Wallac Model 1250 and Model 1251 Luminometers).Other instrumentswould be considered when they become available.Please notify ASTM Subcom-mittee D34.09 if you are aware of any additional systems or instruments capable ofperforming this testing.5At present(1993)use of the color correction scheme described in thisprocedure is known to be effective only with the Microbics Corporations