1、Designation:D545895(Reapproved 2020)Standard Test Method forPeel Cling of Stretch Wrap Film1This standard is issued under the fixed designation D5458;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number
2、in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method measures cling between two layers offilm,in both a stretched and unstretched condition.1.2 The values stated in inch-pound units
3、are to be regardedas standard.The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility o
4、f the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization establis
5、hed in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D996 Terminology of Packaging and Distribution Environ-mentsD1898 Prac
6、tice for Sampling of Plastics(Withdrawn 1998)3D4332 Practice for Conditioning Containers,Packages,orPackaging Components for TestingE122 Practice for Calculating Sample Size to Estimate,WithSpecified Precision,the Average for a Characteristic of aLot or ProcessE691 Practice for Conducting an Interla
7、boratory Study toDetermine the Precision of a Test Method3.Terminology3.1 DefinitionsGeneral definitions for packaging and dis-tribution environments are found in Terminology D996.3.2 Definitions of Terms Specific to This Standard:3.2.1 clingthe property of a materials ability to adhere toitself.3.2
8、.2 stretch wrap materiala material used for over-wrapping which,when applied under tension,elongates,andthrough elastic recovery,conforms to the item(s)packaged.4.Summary of Test Method4.1 This test method is a peel cling procedure.A 1 in.(25mm)wide film strip is adhered to a flat film attached to a
9、ninclined surface.The force required to remove the film stripfrom the flat film is measured.5.Significance and Use5.1 Cling is of critical importance in maintaining a tightwrap after a load is stretch wrapped.6.Equipment and Preparation6.1 ApparatusAuniversal testing machine with a constantrate of g
10、rip separation equipped,as follows:6.1.1 One lightweight jaw equipped with 1 by 1.5 in.(25 by38 mm)flat rubber-faced grips,6.1.2 Cling attachment(see Figs.1-5),6.1.3 Cling clamp(see Fig.6),6.1.4 Load cell,500-g load capacity,6.1.5 If using pneumatic grips,air supply,60 to 70 psi withappropriate filt
11、er,6.1.6 Sample template,picture-frame style with inside di-mensions of 5 by 20 in.(125 by 500 mm),6.1.7 Precision sample cutter,1 6 0.001 in.(25.4 6 0.03mm)width,with precision of 1 6 0.001 in.(25.4 6 0.03 mm),46.1.8 Single-edged safety razor blade,6.1.9 Synthetic bristle paint brush,2 in.(50 mm)wi
12、de,6.1.10 Ruler,12 in.(approximately 300 mm),6.1.11 Separation paper,8.5 by 12 in.(approximately 125by 280 mm)bond,1This test method is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.25 on Palletizingand Unitizing of Loads.Current editio
13、n approved Nov.1,2020.Published November 2020.Originallyapproved in 1994.Last previous edition approved in 2012 as D5458 95(2012).DOI:10.1520/D5458-95R20.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStand
14、ards volume information,refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4JDC-1-10 Cutter is available from Thwing-Albert Instrument Co.,10960Dutton Rd.,Philadelphia,PA 19154 or other manufacturers.Cop
15、yright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International
16、 Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1NOTE11 in.=25 mm.FIG.1 Overall FixtureNOTE11 in.=25 mm.FIG.2 Incline SurfaceD5458 95(2020)26.1.12 String,24 in.(approximately 610 mm)nonelastic,such as dental floss or fishing line,6.1.13 Steel rod,approximately 0.25 in.(6 mm)in diameterand 10 in.(255 mm)long.6.1.14 Cutting surface,approximately 36 by 36 in.(approxi-mately 900 by 900 mm)plate glass,0.25 in.(6 mm)thick.6.2 Prepa