1、Designation:D554204(Reapproved 2009)Standard Test Methods forTrace Anions in High Purity Water by Ion Chromatography1This standard is issued under the fixed designation D5542;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year o

2、f last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 These test methods cover the determination of trace(g/L)levels of fluoride,acetate,formate,chloride,phosphate,and sulfate

3、 in high purity water using ion chromatography incombination with sample preconcentration.Other anions,suchas bromide,nitrite,nitrate,sulfite,and iodide can be deter-mined by this method.However,since they are rarely presentin significant concentrations in high purity water,they are notincluded in t

4、his test method.Two test methods are presentedand their ranges of application,as determined by a collabora-tive study,are as follows:Range Tested(g/L Added)Limit of DetectionA(Single Operator)(g/L)SectionsTest Method A:715Chloride0240.8Phosphate039BSulfate0551.8Test Method B:1623Fluoride0140.7Acetat

5、e04146.8Formate03465.6ALimit of detection is lowest measurable concentration not reportable as zero at99%level of confidence as per EPRI study as cited in Sections 15 and 23.BInsufficient data to calculate limit of detection.1.2 It is the users responsibility to ensure the validity ofthese test meth

6、ods for waters of untested matrices.1.3 The common practical range of Test Method A is asfollows:chloride,1 to 100 g/L,phosphate,3 to 100 g/L,andsulfate,2 to 100 g/L.1.4 The common practical range of Test Method B is asfollows:fluoride,1 to 100 g/L,acetate,10 to 200 g/L,andformate,5 to 200 g/L.1.5 T

7、he values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate

8、safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D1066 Practice for Sampling SteamD1129 Terminology Relating to WaterD1192 Guide for Equipment for Sampling Water and Steamin Closed Conduits(Withdrawn 2003)3D

9、1193 Specification for Reagent WaterD3370 Practices for Sampling Water from Closed ConduitsD3856 Guide for Management Systems in LaboratoriesEngaged in Analysis of WaterD4210 Practice for Intralaboratory Quality Control Proce-dures and a Discussion on Reporting Low-Level Data(Withdrawn 2002)3D4453 P

10、ractice for Handling of High Purity Water SamplesD5810 Guide for Spiking into Aqueous SamplesD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water Analysis3.Terminology3.1 Definitions:3.1.1 For definitions of terms used in these test methodsrefer to Terminology

11、 D1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 analytical columnsa combination of one or moreguard columns followed by one or more separator columnsused to separate the ions of interest.It should be rememberedthat all of the columns in series contribute to the overallcapacity of the

12、 analytical column set.3.2.2 breakthrough volumethe maximum sample volumethat can be passed through a concentrator column before theleast tightly bound ion of interest is eluted.3.2.3 concentrator columnan ion exchange column usedto concentrate the ions of interest and thereby increase methodsensiti

13、vity.1These test methods are under the jurisdiction of ASTM Committee D19 onWater and are the direct responsibility of Subcommittee D19.03 on Sampling Waterand Water-Formed Deposits,Analysis of Water for Power Generation and ProcessUse,On-Line Water Analysis,and Surveillance of Water.Current edition

14、 approved May 1,2009.Published June 2009.Originallyapproved in 1994.Last previous edition approved in 2004 as D554204.DOI:10.1520/D5542-04R09.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume

15、information,refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 3.2.4 eluantthe ionic mobile p

16、hase used to transport thesample through the exchange column.3.2.5 guard columna column used before the separatorcolumn to protect it from contaminants,such as particulatematter or irreversibly retained materials.3.2.6 ion chromatographya form of liquid chromatogra-phy in which ionic constituents are separated by ion exchangefollowed by a suitable detection means.3.2.7 resolutionthe ability of an analytical column toseparate constituents under specific test conditions.3.2.8 separator columnthe i