收藏 分享(赏)

ASTM_D_5241_-_92_2017.pdf

上传人:益****师 文档编号:177361 上传时间:2023-03-04 格式:PDF 页数:5 大小:90.19KB
下载 相关 举报
ASTM_D_5241_-_92_2017.pdf_第1页
第1页 / 共5页
ASTM_D_5241_-_92_2017.pdf_第2页
第2页 / 共5页
ASTM_D_5241_-_92_2017.pdf_第3页
第3页 / 共5页
ASTM_D_5241_-_92_2017.pdf_第4页
第4页 / 共5页
ASTM_D_5241_-_92_2017.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:D524192(Reapproved 2017)Standard Practice forMicro-Extraction of Water for Analysis of Volatile and Semi-Volatile Organic Compounds in Water1This standard is issued under the fixed designation D5241;the number immediately following the designation indicates the year oforiginal adoption o

2、r,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice covers standard procedures for extractionof volatile and semi-volatile

3、organic compounds from waterusing small volumes of solvents.1.2 The compounds of interest must have a greater solubil-ity in the organic solvent than the water phase.1.3 Not all of the solvents that can be used in microextraction are addressed in this practice.The applicability of asolvent to extrac

4、t the compound(s)of interest must be demon-strated before use.1.4 This practice provides sample extracts suitable for anytechnique amenable to solvent injection such as gas chroma-tography or high performance liquid chromatography(HPLC).1.5 The values stated in SI units are to be regarded asstandard

5、.No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine t

6、he applicability of regulatory limitations prior to use.For specific hazard statements,see Section 91.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of Internationa

7、l Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD3370 Practices for Sampling Water from Closed ConduitsD3694 Pract

8、ices for Preparation of Sample Containers andfor Preservation of Organic ConstituentsD3856 Guide for Management Systems in LaboratoriesEngaged in Analysis of WaterD3973 Test Method for Low-Molecular Weight HalogenatedHydrocarbons in WaterD4210 Practice for Intralaboratory Quality Control Proce-dures

9、 and a Discussion on Reporting Low-Level Data(Withdrawn 2002)3D4448 Guide for Sampling Ground-Water Monitoring WellsD5175 Test Method for Organohalide Pesticides and Poly-chlorinated Biphenyls in Water by Microextraction andGas Chromatography3.Summary of Practice3.1 This practice employs liquid/liqu

10、id extraction to isolatecompounds of interest.The sample is added to an extractiondevice.The solvent may be added to the sample container or anextraction device and extracted for a period of 5 min.Thesolvent is then ready for analysis.If required,the pH may beadjusted and salt may be added prior to

11、extraction to increasethe extraction specificity and efficiency.3.2 The solvent extract may be further processed usingsample clean-up and concentration techniques.The analytes inthe solvent may be analyzed using instrumental methods forspecific volatile or semivolatile organic compounds.Thispractice

12、 does not include sample extract clean-up methods.4.Significance and Use4.1 This practice provides a general procedure for thesolvent extraction of volatile and semi-volatile organic com-pounds from a water matrix.Solvent extraction is used as theinitial step in the solvent extraction of organic con

13、stituents forthe purpose of quantifying extractable organic compounds.4.2 Typical detection limits that can be achieved usingmicro-extraction techniques with gas chromatography(GC)with flame ionization detector(FID),electron capture detector1This practice is under the jurisdiction of ASTM Committee

14、D19 on Water andis the direct responsibility of Subcommittee D19.06 on Methods for Analysis forOrganic Substances in Water.Current edition approved Dec.15,2017.Published January 2018.Originallyapproved in 1992.Last previous edition approved in 2011 as D5241 92(2011).DOI:10.1520/D5241-92R17.2For refe

15、renced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.

16、astm.org.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1(ECD),or with a mass spectrometer(GC/MS)range frommilligrams per lit

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2