收藏 分享(赏)

ASTM_D_5075_-_01_2022.pdf

上传人:益****师 文档编号:177843 上传时间:2023-03-04 格式:PDF 页数:8 大小:128.03KB
下载 相关 举报
ASTM_D_5075_-_01_2022.pdf_第1页
第1页 / 共8页
ASTM_D_5075_-_01_2022.pdf_第2页
第2页 / 共8页
ASTM_D_5075_-_01_2022.pdf_第3页
第3页 / 共8页
ASTM_D_5075_-_01_2022.pdf_第4页
第4页 / 共8页
ASTM_D_5075_-_01_2022.pdf_第5页
第5页 / 共8页
ASTM_D_5075_-_01_2022.pdf_第6页
第6页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:D507501(Reapproved 2022)Standard Test Method forNicotine and 3-Ethenylpyridine in Indoor Air1This standard is issued under the fixed designation D5075;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revis

2、ion.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers the sampling/analysis of nico-tine and 3-ethenylpyridine(3-EP)in indoor air.This testmethod is based upon the

3、 collection of nicotine and 3-EP byadsorption on a sorbent resin,extraction of nicotine and 3-EPfrom the sorbent resin,and determination by gas chromatog-raphy(GC)with nitrogen selective detection(1).21.2 The active samplers consist of an macroreticularpolystyrene-divinylbenzene copolymer(for exampl

4、e,XAD-4)sorbent tube attached to a sampling pump.Macroreticularpolystyrene-divinylbenzene copolymer is referred to“sorbentresin”throughout this method.This test method is applicable topersonal or area sampling.1.3 This test method is limited in sample duration by thecapacity of the sorbent tube for

5、nicotine(about 300 g).Thistest method has been evaluated up to 24-h sample duration;however,samples are typically acquired for at least 1 h(sometimes only 1 h)(2).1.4 For this test method,limits of detection(LOD)andquantitation(LOQ)for nicotine at a sampling rate of 1.5 L/minare,respectively,0.11 g/

6、m3and 0.37 g/m3for 1-h sampleduration and 0.01 g/m3and 0.05 g/m3for 8-h sampleduration.The LOD and LOQ for 3-EP at a sampling rate of 1.5L/min are,respectively,0.06 g/m3and 0.19 g/m3for 1-hsample duration and 0.01 g/m3and 0.02 g/m3for 8-h sampleduration(2).Both LOD and LOQ can be reduced by increasi

7、ngthe sensitivity of the thermionic specific detector.1.5 UnitsThe values stated in SI units are to be regardedas standard.No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is therespon

8、sibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.Specific precautionary information is given in 13.6.1.7 This international standard was developed in accor-dance with inte

9、rnationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:3D1356 Te

10、rminology Relating to Sampling and Analysis ofAtmospheresD1357 Practice for Planning the Sampling of the AmbientAtmosphereD3631 Test Methods for Measuring Surface AtmosphericPressureD5337 Practice for Flow Rate Adjustment of Personal Sam-pling PumpsE260 Practice for Packed Column Gas ChromatographyE

11、355 Practice for Gas Chromatography Terms and Relation-ships3.Terminology3.1 DefinitionsFor definitions of terms used in this testmethod,refer to Terminology D1356 and Practice E355.3.2 Definitions of Terms Specific to This Standard:3.2.1 environmental tobacco smoke(ETS)an aged,dilutecomposite of ex

12、haled tobacco smoke(exhaled mainstreamsmoke)and smoke from tobacco products(sidestream smoke).3.2.2 nitrogen-phosphorus detector(NPD)a highly sensi-tive device selective for detection of nitrogen-and phosphorus-containing organic compounds.4.Summary of Test Method4.1 A known volume of air is drawn t

13、hrough a sorbentsampling tube containing resin to adsorb the nicotine and 3-EPpresent.1This test method is under the jurisdiction of ASTM Committee D22 on AirQuality and is the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition approved March 1,2022.Published April 2022.Origi

14、nallyapproved in 1990.Last previous edition approved in 2017 as D5075 01(2017)1.DOI:10.1520/D5075-01R22.2The boldface numbers in parentheses refer to a list of references at the end ofthe text.3For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at servi

15、ceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with inte

16、rnationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.14.2 The sorbent tube contents are transferred to a 2-mLautosampler vial,and the nicotine and 3-EP are desorbed withethyl acetate containing 0.01%triethylamine and a knownquantity of quinoline,the internal standard.4.3 An aliquot of the desorbed sampl

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2