1、Designation:D 5082 99Standard Practice forApplication of Mechanically Attached Poly(Vinyl Chloride)Sheet Roofing1This standard is issued under the fixed designation D 5082;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of l

2、ast revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon(e)indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice covers the minimum requirements for theinstallation of mechanically attached poly(vinyl chloride)roof-ing.1.2

3、 For the purpose of this application practice,the structureand deck are assumed to be mechanically sound,able to acceptthe weight of the membrane and other roofing system materi-als,comply with local building codes,and other roofingrequirements.The insulation layer(s)and vapor retarder,ifspecified,a

4、re assumed to be in place,secured,and acceptablefor use with the membrane.1.3 This standard does not purport to address all of thesafety problems associated with its use.It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applica

5、bility of regulatorylimitations prior to use.For specific hazard statements,seeSection 7.2.Referenced Documents2.1 ASTM Standards:D 1079 Terminology Relating to Roofing,Waterproofing,and Bituminous Materials2D 4434 Specification for Poly(Vinyl Chloride)Sheet Roof-ing22.2Other Standards:Factory Mutua

6、l Research Corporation Approval Standard,Number FM 4470,Class I Roof Covers,April 198633.Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice,see Terminology D 1079.4.Materials Definitions4.1 Poly(Vinyl Chloride)Sheets RoofingRoofing materialthat meets the requirements of Specif

7、ication D 4434.4.2 LapSeamSealantWhenrequiredbythemanufacturer/supplier,provide a compatible sealant that willbe applied to the exposed edge of the seam.4.3 Mechanical AffxmentsThe mechanical fasteners andplates,discs,bars,or strips specified for use in the system mustmeet the guidelines outlined in

8、 FM Standard 4470 for surfacecorrosion and shall meet the specific requirements of themanufacturer/supplier.5.Delivery of Materials5.1 Deliver materials in suppliers unopened containers andpackages.6.Storage and Handling of Materials6.1 Elevate stored materials and under protective covering.Roll goo

9、ds shall be stored in a horizontal position,and in amanner that prevents the suppliers markings from beingdestroyed.6.2 Store solvents in proper containers to prevent dilution orcontamination,or both.6.3 Store flammable materials in original closed containersaway from any ignition source.6.4 Consult

10、 membrane manufacturer/supplier for additionaldirection.7.Safety Hazards7.1 Store flammable materials in a manner that will not posea fire hazard.7.2 Shut down roof top air handling equipment and airintakes in the work area to reduce odors from entering thebuilding.8.Environmental Conditions8.1 Inst

11、all roofing components during weather conditionsthat do not interfere with pliability,or workability.8.2 Installation outside of these conditions require specialconditions beyond the scope of this practice.8.3 Wind may cause difficult working conditions.Tempo-rary ballasting of roofing sheets may be

12、 required.Worksurfaces must be protected from windblown dirt and debris.9.Substrate Preparation9.1 Surfaces to receive sheets shall be sufficiently clean ofcontaminants such as dirt,debris,loose materials,and visiblemoisture.Remove sharp objects that could damage the roofing.1This practice is under

13、the jurisdiction of ASTM Committee D-8 on Roofing,Waterproofing,and Bituminous Materials and is the direct responsibility ofSubcommittee D08.18 on Nonbituminous Organic Roof Coverings.Current edition approved July 10,1999.Published September 1999.Originallypublished as D 5082 90.Last previous editio

14、n D 5082 90(97).2Annual Book of ASTM Standards,Vol 04.04.3Available from Factory Mutual Research Corp.,1151 Boston-ProvidenceTurnpike,Norwood,MA 02062.1Copyright ASTM,100 Barr Harbor Drive,West Conshohocken,PA 19428-2959,United States.9.2 All gaps and joints between substrate components inexcess of1

15、4in.shall be filled with like materials.10.Installation10.1 If required by the contract,submit shop drawings to theawarding authority for review and approval.Install sheets inaccordance with the approved drawings.10.2 Use care not to damage materials when handling.Distribute materials in such a mann

16、er that the roof deck is notoverloaded.410.2.1 Use care during installation to avoid damaging thesubstrate.10.2.2 Start the sheet installation at the high point of theroof and work to the lowest point to avoid the possibility ofwater penetrating under the completed roof system.10.2.3 Orient field seams with sheet overlaps to shed wateror be parallel to the direction of water flow when possible.10.3 Do not puncture,fracture,or delaminate the substrateto which the roofing is to be installed.Damage