收藏 分享(赏)

ASTM_D_4285_-_83_2012.pdf

上传人:益****师 文档编号:179315 上传时间:2023-03-04 格式:PDF 页数:2 大小:57KB
下载 相关 举报
ASTM_D_4285_-_83_2012.pdf_第1页
第1页 / 共2页
ASTM_D_4285_-_83_2012.pdf_第2页
第2页 / 共2页
亲,该文档总共2页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:D428583(Reapproved 2012)Standard Test Method forIndicating Oil or Water in Compressed Air1This standard is issued under the fixed designation D4285;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision

2、.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method is used to determine the presence of oilor water in compressed air used for abrasive blast cleaning,airblast cleaning,a

3、nd coating application operations.1.2 The values stated in inch-pound units are to be regardedas standard.No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the u

4、ser of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.For specific hazardstatements,see Section 4.2.Significance and Use2.1 Clean compressed air is required to prevent contamina-tion of coating materials and

5、 surfaces being prepared forcoating.This test method is a visual examination technique fordetermining oil or water in compressed air.Other types ofcontamination may require additional analytical techniques fordetection.3.Apparatus and Materials3.1 Absorbent Collector,such as white absorbent paper or

6、cloth and rigid backing for mounting absorbent collector,or3.2 Nonabsorbent Collector,such as rigid transparent plas-tic,approximately14in.thick.4.Cautions4.1 To avoid false indications prior to testing:4.1.1 Allow compressed air system to reach operatingconditions,and4.1.2 Allow air to discharge at

7、 operating conditions toremove accumulated condensation in the system.4.2 Fasten the collector material to the rigid backing.Precaution:Avoid personal contact with the air stream.5.Sampling5.1 Conduct the test on discharging air as close to the usepoint as possible and after the inline oil and water

8、 separators.6.Procedure6.1 Use either the absorbent or nonabsorbent collector.6.2 Position the collector within 24 in.of the air-dischargepoint,centered in the air stream.6.3 Adjust air discharge so that the collector remains intactduring the test.Allow air to discharge onto the collector for aminim

9、um of 1 min.6.4 Visually examine the collector for the presence orabsence of oil or water,or both.7.Interpretation of Results7.1 Any indication of oil discoloration on the collector shallbe cause for rejection of the compressed air for use in abrasiveblast cleaning,air blast cleaning,and coating app

10、licationoperations.7.2 Any indications of water contamination on the collectorshall be cause for rejection of the compressed air for use inthose applications where water is detrimental,such as abrasiveblast cleaning,air blast cleaning,and coating applicationoperations.8.Precision and Bias8.1 No prec

11、ision or bias statement has been established forthis test method.9.Keywords9.1 compressed air;oil and water in compressed air1This test method is under the jurisdiction of ASTM Committee D33 onProtective Coating and Lining Work for Power Generation Facilities and is the directresponsibility of Subco

12、mmittee D33.05 on Application and Surface Preparation.Current edition approved May 1,2012.Published May 2012.Originallyapproved in 1983.Last previous edition approved in 2005 as D4285-83(2005).DOI:10.1520/D4285-83R12.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA

13、 19428-2959.United States1 ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard.Users of this standard are expressly advised that determination of the validity of any such patent rights,and the riskof infring

14、ement of such rights,are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised,either reapproved or withdrawn.Your comments are invited either for revision of this standard or

15、for additional standardsand should be addressed to ASTM International Headquarters.Your comments will receive careful consideration at a meeting of theresponsible technical committee,which you may attend.If you feel that your comments have not received a fair hearing you shouldmake your views known

16、to the ASTM Committee on Standards,at the address shown below.This standard is copyrighted by ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959,United States.Individual reprints(single or multiple copies)of this standard may be obtained by contacting ASTM at the aboveaddress or at 610-832-9585(phone),610-832-9555(fax),or serviceastm.org(e-mail);or through the ASTM website(www.astm.org).Permission rights to photocopy the standard may also be secured from the AST

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2