收藏 分享(赏)

ASTM_D_3544_-_76_1996.pdf

上传人:益****师 文档编号:179767 上传时间:2023-03-04 格式:PDF 页数:6 大小:37.25KB
下载 相关 举报
ASTM_D_3544_-_76_1996.pdf_第1页
第1页 / 共6页
ASTM_D_3544_-_76_1996.pdf_第2页
第2页 / 共6页
ASTM_D_3544_-_76_1996.pdf_第3页
第3页 / 共6页
ASTM_D_3544_-_76_1996.pdf_第4页
第4页 / 共6页
ASTM_D_3544_-_76_1996.pdf_第5页
第5页 / 共6页
ASTM_D_3544_-_76_1996.pdf_第6页
第6页 / 共6页
亲,该文档总共6页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:D 3544 76(Reapproved 1996)Standard Guide forReporting Test Methods and Results on High ModulusFibers1This standard is issued under the fixed designation D 3544;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of l

2、ast revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon(e)indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1.Scope1.1 Committee D-30,having conducted several in

3、terlabora-tory tests of high modulus fibers,believes that many types ofequipment and techniques will yield consistent data character-izing the tensile strength and modulus of high modulus fibers.The most important consideration is the complete descriptionof the test methods.1.2 This guide consists o

4、f the following three parts:1.2.1 Part ADescription of Equipment and TechniquesThis section describes the equipment and the techniques usedfor each series of tests.The section is complete and universal,and should be reviewed by the engineer or scientist responsiblefor the overall test program.1.2.2

5、Part BDescription of Test SpecimensThis sectiondescribes each type of fiber tested in a particular series,and canbe prepared by the test technician.1.2.3 Part CReport of Tension Test ResultsThis sectionsummarizes the results of each test series.The format simpli-fies the reporting of essential data.

6、Additional information maybe required to report the results of tests on specific fiber types.1.3 This standard may involve hazardous materials,opera-tions,and equipment.This standard does not purport toaddress all of the safety problems associated with its use.It isthe responsibility of the user of

7、this standard to establishappropriate safety and health practices and determine theapplicability of regulatory limitations prior to use.2.Significance and Use2.1 The purpose of this guide is to be a research tool(1)toaid in the analysis and correlation of test results obtained fromthe use of various

8、 types of tension testing equipment bydifferent investigators and(2)to identify the important detailsthat must be made in testing to make the results easilyunderstood and comparable with the results of other investiga-tors.NOTE1The ASTM practice of providing units of measure in theInternational Syst

9、em of Units(SI)has been used.The SI unit for pressureor stress is pascal(Pa 5 N/m2)or megapascal(MPa 5 MN/m2).Thefollowing equivalents may be helpful:1 lbf 5 4.448 N1 psi 5 6895 Pa 5 6.895 kPa1000 psi 5 6.895 MPaPART ADESCRIPTION OF EQUIPMENT AND TECHNIQUESDESCRIPTION OF TENSION TEST MACHINEDate_Man

10、ufacturer,Model,and ModificationsOrientation of Test Specimen:HorizontalhVerticalhOtherDescribeMethod and Rate of Strain or Load Application:DiscontinuoushContinuoushConstant Rate of TraversehConstant Rate of ElongationhConstant Rate of LoadhOtherDescribeTime to Failure _ sDescription of Load-Measur

11、ing System:Capacity _ N(_ lbf),max1This guide is under the jurisdiction of ASTM Committee D-30 on HighModulus Fibers and Their Compositesand is the direct responsibility of Subcom-mittee D30.03 on Constituent/Precursor Properties.Current edition approved Oct.29,1976.Published January 1977.1Copyright

12、 ASTM,100 Barr Harbor Drive,West Conshohocken,PA 19428-2959,United States.NOTICE:This standard has either been superseded and replaced by a new version or discontinued.Contact ASTM International(www.astm.org)for the latest information.Deflection of Sensing Element at Load _ mm(_ in.),maxLoad Range _

13、 N(_lbf)Type of Measuring ElementResolution and Estimate of ErrorDescription of Elongation Measuring System:Jaw SeparationhExtensometer on SamplehOpticalhContinuous TrackinghDiscontinuous or Manual TrackinghOtherDescribeResolution and Estimate of ErrorMethod Used to Determine System ComplianceCompli

14、ance Correction Value _ mm/N(_ in./lbf)Load Calibration Procedure:Estimate of ErrorElongation Calibration Procedure:Estimate of ErrorLinearity of Recording Unit(indicate maximum departure from linear response):Load Indication _%Elongation Indication _%Response Time of Recording Unit _ s full scaleME

15、ASUREMENT OF CROSS-SECTIONAL AREAMethod of Measurement:MicrometerhMicroscopicalLongitudinal ViewhMicroscopicalTransverse ViewhCalculated from Linear DensityhOtherDescribeTime When Measurement Was Made:Before Test on Each SpecimenhAfter Test on Each SpecimenhOn Group of SpecimensAveragehLocation of M

16、easurements Along Lengthat fracture h in gage length h other _:Number of Measurements Made on Each Fiber or Strand _Estimate of Error in Cross-Sectional Area _%MEASUREMENT OF SPECIMEN GAGE LENGTHDistance Between Fiber or Strand Mounts:Method of MeasurementResolution and Estimate of ErrorLength of Fiber or Strand over Which Elongation Was Measured:General DescriptionResolution and Estimate of ErrorLocation and Type of Gage MarksMETHOD OF GRIPPING AND ALIGNING FIBER OR STRANDFiber or Strand Mounti

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2