收藏 分享(赏)

ASTM_D_3051_-_87_scan.pdf

上传人:益****师 文档编号:179995 上传时间:2023-03-04 格式:PDF 页数:3 大小:203.46KB
下载 相关 举报
ASTM_D_3051_-_87_scan.pdf_第1页
第1页 / 共3页
ASTM_D_3051_-_87_scan.pdf_第2页
第2页 / 共3页
ASTM_D_3051_-_87_scan.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、-(-I S-/1 ASTM D3053 87 m 0757530 0028703 5 m 1 Designation:D 3051-87 AMERICAN SOCIETY FOR TESTING AND MATERIALS 1916 Race St.,Philadelphia,Pa.19103 Reprinted from the Annual Book of ASTM Standards,Copyright ASTM If not listed in the current combined index.will appear in lhe next edition Standard Pr

2、actice for TEST METHODS CARBON BLACK-STATING THE PRECISION OF ASTM This standard is issued under the fixed designation D3051;the number immediately following the designation indicates the year of original adoption or,in the case of revision,the year of last revision.A ouniber in parentheses indicate

3、s the year of last reapproval.A superscript epsilon(E)indicates an editorial change since the last revision or reapproval.1.scope 1.I This practice offers simplified guidelines for stating the precision of ASTM test methods for carbon black as determined in Practice D 3396.1.2 The two components of

4、precision utilized are the repeatability of a test and the reproduci-bility of a test.1.2.1 The component of repeatability is in-tended to be relevant to within-laboratory prob-lems concerning statistical process control limits,quality assurance,and research.The repeatability represents the inherent

5、 error of the test method.1.2.2 The component of reproducibility is in-tended to be relevant to between-laboratory problems concerning purchase specifications,quality assurance,and industry standard refer-ence blacks.The reproducibility represents the inherent test error plus a component of variabil

6、-ity due to different apparatus,reagents,ambient conditions,technique,and so forth,between lab-oratories.i.3 This standard may involve hazardous ma-terials,operations,and equipment.This standard does not purport to address all o f the safety prob-lems associated with its irse.it is the responsibil-i

7、ty o f the user ofthis standard to establish appro-priate safery and health practices and determine the applicability o f regulaloty limitations prior to irse.2.Referenced Document 2.I ASTM Standard:D 3396 Practice for Carbon Black-Measuring the Precision of ASTM Test Methods 3.Definitions 3.1 test

8、result-the final result of one deter-mination or multiple determinations run simul-taneously or on the same day by the same tech-nicians depending upon the directions of the procedures.3.2 test precision-a measure of the ability of a test procedure in obtaining repeated values within and among labor

9、atories on essentially identical samples.3.3 sample-a homogenized portion of car-bon black that usually represents a larger lot of nominally uniform material.3.4 standard deviation,s-a measure of the agreement between test results.3.5 repeatability standard deviation,s r a measure of the agreement b

10、etween test results obtained in the same laboratory on different days by the same technician(or the same set of tech-nicians)using the same apparatus and technique on the same sample.3.5.1 Discussion-The phrase“or the same set of technicians”refers to cases in which com-mon laboratory practice is to

11、 use more than one technician to carry out a test procedure.The phrase“or essentially the same sample”refers to cases in which the original sample is destroyed by the test procedure.This practice is under the jurisdiction of ASTM Committee D-24 on Carbon Black,and is the direct responsibility of Sub

12、 committee D24.61 on Carbon Black Sampling and Statistical Analviic.C;Gnt edition approved March 27,1987.Published May 1987.Originally published as D 305 1-72.Last previous edition D3051-76(1981).Annual mk OASTM Siandards,Vol 09.01.NOTICE:This standard has either been superseded and replaced by a ne

13、w version or discontinued.Contact ASTM International(www.astm.org)for the latest information.ASTM D305L 87 U 0759530 0028702 7 U 3.6 reproducibility standard deviation,sL-a measure of the agreement between test results obtained in different laboratories on different days by different technicians app

14、lying the same test method to essentially the same sample.3.7 repeatability coeflcient o f variation,uW percent-the repeatability standard deviation di-vided by the average value of the test results from which it was calculated and then multiplied by 100%.3.7.1 Discussion-This statistic is used as a

15、 measure of the agreement between test results when the standard deviation is proportional to the average value of the property being tested.3.8 reproducibility coeflcient o f variation,ur.percent-the reproducibility standard deviation divided by the average value of the test result from which it wa

16、s calculated and then multiplied by 100%.3J.1 Discussion-This statistic is used as a measure of the agreement between test results when the standard deviation is proportional to the average value of the property being tested.4.Units of Measurement 4.1 A test result is expressed either in physico-chemical units or in percent,as defined in each test method.4.2 A standard deviation is expressed in the original test units when they are physico-chemi-cal units.A standard deviation is expressed in per

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2