1、Designation:D280717Standard Test Method forChromic Oxide in Leather(Perchloric Acid Oxidation)1This standard is issued under the fixed designation D2807;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A numb
2、er in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S.Department of Defense.1.Scope1.1 This test method covers the determination of chromicoxide
3、in leathers that have been partly or completely tannedwith chromium compounds.In general the samples will con-tain between 1 and 5%chromium,calculated as chromicoxide.1.2 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.3 This s
4、tandard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.See Section 7 forspecific sa
5、fety hazards.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization Technica
6、lBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D2617 Test Method for Total Ash in LeatherD2813 Practice for Sampling Leather for Physical andChemical TestsD2868 Test Method for Nitrogen Content(Kjeldahl)andHide Substance Content of Leather,Wet Blue and WetWhiteD3495 Test
7、Method for Hexane Extraction of LeatherD3790 Test Method for Volatile Matter(Moisture)ofLeather by Oven Drying3.Summary of Test Method3.1 The perchloric acid method is applied to the ashobtained in Test Method D2617.In the acid digestion,anyremaining organic matter is destroyed and the chromiumoxidi
8、zed to the hexavalent state.On dilution,the chromium istitrated volumetrically with thiosulfate or ferrous salt.Theperchloric acid method requires less manipulation than proce-dures based on fusion of the ash,but care must be takenbecause of potential hazards in the use of this reagent.Theperchloric
9、 acid method also tends to give low results.4.Significance and Use4.1 The procedure described is specific for chromium inleather.Vanadium is the only common interfering element andthis is rarely present in quantity.The precision and accuracy ofthe methods are usually at least as good as the sampling
10、 of theleather itself.4.2 The chromium content of leather relates to the degree oftannage obtained,and hence may be a matter for specificationin the purchase of leather.The procedure described providesadequate accuracy for this purpose.5.Apparatus5.1 Potentiometric Titration EquipmentThis is require
11、d inan alternative method for titrating chromium(Cr6+)withferrous ammonium sulfate solution.The equipment consists of:5.1.1 Stirrer.5.1.2 Calomel and Platinum Electrodes.5.1.3 PotentiometerA variety of instruments is satisfac-tory.3The most convenient common feature of these instru-ments is a null-p
12、oint device(either a cathode-ray electron tubeor galvanometer)that will signal the abrupt change occurringin the potential when the end point is reached.5.1.4 In carrying out the titration,the electrodes are im-mersed in the sample,the solution agitated by the stirrer,and1This test method is under t
13、he jurisdiction of ASTM Committee D31 on Leatherand is the direct responsibility of Subcommittee D31.06 on Chemical Analysis Thistest method was developed in cooperation with the American Leather ChemistsAssn.Current edition approved April 1,2017.Published May 2017.Originallyapproved in 1969.Last pr
14、evious edition approved in 2015 as D2807 93(2015).DOI:10.1520/D2807-17.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM web
15、site.3Satisfactory equipment include,among others the following:the Kelley,Serfass,and Fisher tritrimeters,Leeds&Northrup potentiometers,and Beckman pHmeters.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was de
16、veloped in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.1 the potential balanced with the galvanometer or cathode-raytube.Titrant is added dropwise until a sharp permanent changein potential occurs.5.2 Perchloric Acid Hood.6.Reagents6.1 Purity of ReagentsReagent grade chemica