收藏 分享(赏)

ASTM_D_1991_-_15_2019.pdf

上传人:益****师 文档编号:181969 上传时间:2023-03-04 格式:PDF 页数:3 大小:84.06KB
下载 相关 举报
ASTM_D_1991_-_15_2019.pdf_第1页
第1页 / 共3页
ASTM_D_1991_-_15_2019.pdf_第2页
第2页 / 共3页
ASTM_D_1991_-_15_2019.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:D199115(Reapproved 2019)Standard Test Method forRubber Chemicals2-Mercaptobenzothiazole(MBT)Assay1This standard is issued under the fixed designation D1991;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last

2、revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method covers a procedure for the assay of2-mercaptobenzothiazole(MBT).It is based on a potentiomet-ric titration of M

3、BT with sodium hydroxide.1.2 The assay is determined as percent by mass.1.3 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It

4、 is theresponsibility of the user of this standard to establish appro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on st

5、andard-ization established in the Decision on Principles for theDevelopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Referenced Documents2.1 ASTM Standards:2D4483 Practice for Evaluating Precision for Tes

6、t MethodStandards in the Rubber and Carbon Black ManufacturingIndustries3.Summary of Test Method3.1 A sample of MBT is dissolved in ethanol.The solutionis titrated potentiometrically using a solution of sodium hy-droxide as the titrant.4.Significance and Use4.1 MBT is commonly used as an accelerator

7、 for rubber andlatex vulcanization.The purity of MBT may be of importancein predicting performance in rubber compounds and this testmethod is designed to assess the purity of MBT.4.2 This test method may be used as a quality control tooland for research and development work.5.Apparatus5.1 Erlenmeyer

8、 Flask,250-cm3.5.2 Analytical Balance,having a sensitivity of 60.1 mg.5.3 Potentiograph.5.4 Glass pH Electrode,and reference electrode.5.5 Graduated Cylinder,200-cm3.6.Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests.Unless otherwise indicated,it is intended thatall re

9、agents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.36.2 Purity of WaterUnless otherwise indicated,referencesto water shall be understood to mean distilled water or water ofequal purity.6.3 Aqueo

10、us Sodium Hydroxide Solution(40 g NaOH in1 dm3of solution)Standardize by accepted analytical tech-niques to ensure that the maximum error of the normalizationfactor is not more than 0.001.6.4 Ethanol,denatured with toluene(in the ratio of 100volumes ethanol to 1 volume toluene).6.5 Toluene.1This tes

11、t method is under the jurisdiction of ASTM Committee D11 on Rubberand Rubber-like Materials and is the direct responsibility of Subcommittee D11.11on Chemical Analysis.Current edition approved Dec.1,2019.Published December 2019.Originallyapproved in 1991.Last previous edition approved in 2015 as D19

12、91 15.DOI:10.1520/D1991-15R19.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals,American Chemical

13、 Society Specifications,AmericanChemical Society,Washington,DC.For Suggestions on the testing of reagents notlisted by the American Chemical Society,see Annual Standards for LaboratoryChemicals,BDH Ltd.,Poole,Dorset,U.K.,and the United States Pharmacopeiaand National Formulary,U.S.Pharmacopeial Conv

14、ention,Inc.(USPC),Rockville,MD.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles f

15、or theDevelopment of International Standards,Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade(TBT)Committee.7.Sampling7.1 Sampling shall be at the discretion of the analyst toobtain as representative a sample as possible,of the lot to betested.8.Procedure

16、8.1 Weigh(to nearest 0.001 g)about 5 g of the specimen,and transfer into a 250-cm3Erlenmeyer flask.Using a gradu-ated cylinder,add 125 cm3denatured ethanol(6.4).Titrate thesolution potentiometrically,using a glass electrode system,with NaOH(6.3)as the titrant(A)(see Fig.1).9.Calculation9.1 From the plot of pH versus millilitres of NaOH,asillustrated in Fig.1,the equivalence point for the potentiomet-ric titration is defined as the inflection point of the curve.Thisinflection point may be estimat

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2