1、Designation:D210901(Reapproved 2011)Standard Test Methods forNonvolatile Matter in Halogenated OrganicSolvents and Their Admixtures1This standard is issued under the fixed designation D2109;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revi

2、sion,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1.Scope1.1 These test methods cover

3、the determination of nonvola-tile matter in halogenated organic solvents and admixtures.1.2 Five test methods are covered,as follows:1.2.1 Test Method AFor halogenated organic solvents oradmixtures having less than 50 ppm nonvolatile matter;orwhere precision better than 610 ppm is required.1.2.2 Tes

4、t Method BFor halogenated organic solvents oradmixtures having more than 50 ppm nonvolatile matter orwhere precision of 60.001%(10 ppm)is satisfactory.1.2.3 Test Method CFor low-boiling halogenated organicsolvents or their admixtures(for example,methylene chloride,trichlorotrifluoroethane)that may s

5、uperheat and cause bump-ing while evaporating to dryness with steam.A precision ofgreater than6 10 ppm can be attained.1.2.4 Test Method DFor rapid measurement of nonvolatilematter in halogenated organic solvents and their admixturesand where precision better than 610 ppm is required.1.2.5 Test Meth

6、od EFor halogenated organic solvents oradmixtures and where precision better than 610 ppm isrequired.1.3 The values stated in SI units are to be regarded as thestandard.1.4 The values stated in SI units are to be regarded asstandard.No other units of measurement are included in thisstandard.1.5 This

7、 standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Terminology2.1 Definitio

8、ns of Terms Specific to This Standard:2.1.1 The term nonvolatile matter should not be construedas equivalent to residue on ignition,ignition residue,or ashcontent.Particulates,sediments,and suspended matter shouldnot be considered part of nonvolatile matter.If these solids arepresent in the sample,t

9、hey should be removed by filtration ordecantation prior to beginning this test method.Nonvolatilematter is considered to be“in solution”with the solvent andthat which will become residual upon drying the solvent at aspecified temperature.2.1.2 Nonvolatile matter and nonvolatile residue are inter-cha

10、ngeable terms.3.Significance and Use3.1 Nonvolatile matter in solvents can adversely affect theircleaning properties.These test methods can be used to controlsoil contamination in the boiling solvent,which if allowed tobecome too high,can decrease the stability of the solvent.3.2 These test methods

11、can be used to establish manufac-turing and purchasing specifications.4.Apparatus4.1 Oven,thermostatically controlled at 105 6 5C.4.2 Evaporating Dish,125-mL capacity,platinum or high-silica glass,Methods A,B,C.4.3 Evaporating Dish(80 45 or 115 50)(Method D).4.4 Steam Bath(or hot plate).4.5 Hot Plat

12、e,(Method D).4.6 Heat Lamp,250 W,(Method E).4.7 Analytical Balance,capable of measuring to 0.0001 g.4.8 Top Loading Balance,capable of weighing to 0.01 g.4.9 Aluminum Weighing Dish,57 18 mm,(Method D).4.10 Aluminum Weighing Dish,200 ML capacity,(MethodE).4.11 1000-mL Volumetric Flask(Test Method A).

13、4.12 100-mL Volumetric Pipet(Test Method B and E).4.13 1000-mL Graduated Cylinder(Test Method C).4.14 1500-mL Erlenmeyer Flask(Test Method C).1These test methods are under the jurisdiction of ASTM Committee D26 onHalogenated Organic Solvents and Fire Extinguishing Agents and are the directresponsibi

14、lity of Subcommittee D26.04 on Test Methods.Current edition approved Aug.1,2011.Published November 2011.Originallyapproved in 1962 as D2109 62 T.Last previous edition approved in 2006 asD2109 01(2006)1.DOI:10.1520/D2109-01R11.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Consho

15、hocken,PA 19428-2959.United States1 TEST METHOD A5.Procedure5.1 Dry a 125-mL capacity platinum(or high-silica glass)evaporating dish in an oven at 105 6 5C and cool in adesiccator.Repeat until the weight is constant or within 0.1 mgof the last weighing.Rinse a clean dry 1000-mL volumetricflask with

16、the solvent and fill to the 1000-mL mark with thesolvent to be tested.Invert the evaporating dish,place it overthe mouth of the flask,hold it firmly in place,and invert theflask.In this position place both dish and flask on a steam bath.Adjust a ring support to hold the flask so the mouth of the flaskis approximately 25 mm above the bottom of the evaporatingdish.Thus held,the flask automatically feeds the solvent to thedish during the evaporation.(WarningThis test methodmust be run in a ventilat