收藏 分享(赏)

ASTM_D_1512_-_15b.pdf

上传人:益****师 文档编号:183765 上传时间:2023-03-04 格式:PDF 页数:4 大小:90.89KB
下载 相关 举报
ASTM_D_1512_-_15b.pdf_第1页
第1页 / 共4页
ASTM_D_1512_-_15b.pdf_第2页
第2页 / 共4页
ASTM_D_1512_-_15b.pdf_第3页
第3页 / 共4页
ASTM_D_1512_-_15b.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:D151215bStandard Test Methods forCarbon BlackpH Value1This standard is issued under the fixed designation D1512;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.A number in parentheses indicates t

2、he year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S.Department of Defense.1.Scope1.1 These test methods,Test MethodABoiling Slurry andTest Method BSonic Slurry,are used to

3、indicate the pH ofthe carbon black surface by measuring the pH of water incontact with the carbon black.NOTE1The pH of the carbon black is often used in this industry toindicate the relative acidity or alkalinity of carbon black and will be usedin the remainder of these test methods to describe this

4、 property.NOTE2Test Method A and Test Method B do not always give thesame results.1.2 The values stated in SI units are to be regarded as thestandard.The values in parentheses are for information only.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its

5、use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD1799 Practice for Carbon BlackSamplin

6、g PackagedShipmentsD1900 Practice for Carbon BlackSampling Bulk Ship-mentsD4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber and Carbon Black ManufacturingIndustriesE70 Test Method for pH of Aqueous Solutions With theGlass Electrode3.Significance and Use3.1 The pH level o

7、f a carbon black is known to affect thevulcanization of some rubber compounds.TEST METHOD ABOILING SLURRY4.Apparatus4.1 pH Meter,(digital is recommended)having an accuracyof 60.05 pH and equipped with a combination electrode andRNC connector.4.2 Container,stainless steel or copper,125 cm3or larger.4

8、.3 Hot Plate.4.4 High Speed Mill,Mixer or Mortar and Pestle.4.5 Beakers,glass,100 cm3graduated with watch glasses.4.6 Magnetic Stir Plate.4.7 Magnetic Stir Bars.5.Reagents5.1 Purity of ReagentsReagent grade chemicals shall beused in all tests.Unless otherwise indicated,it is intended thatall reagent

9、s shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused,provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccu

10、racy of the determination.5.2 Purity of WaterUnless otherwise indicated,referencesto water shall be understood to mean reagent water as definedby Type 1 in Specification D1193.5.3 Distilled Water,high purity.5.4 Buffer Solutions,pH of 4.00,7.00,and 10.00.5.5 Acetone,reagent grade.6.Sampling6.1 Sampl

11、es shall be taken in accordance with PracticesD1799 or D1900.1These test methods are under the jurisdiction of ASTM Committee D24 onCarbon Black and are the direct responsibility of Subcommittee D24.31 onNon-Carbon Black Components of Carbon Black.Current edition approved Dec.1,2015.Published Februa

12、ry 2016.Originallyapproved in 1975.Last previous edition approved in 2015 as D1512 15a.DOI:10.1520/D1512-15B.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standard

13、s Document Summary page onthe ASTM website.3Reagent Chemicals,American Chemical Society Specifications,AmericanChemical Society,Washington,DC.For suggestions on the testing of reagents notlisted by the American Chemical Society,see Analar Standards for LaboratoryChemicals,BDH Ltd.,Poole,Dorset,U.K.,

14、and the United States Pharmacopeiaand National Formulary,U.S.Pharmacopeial Convention,Inc.(USPC),Rockville,MD.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 7.Calibration7.1 Calibrate the pH meter using buffer solutions accordingto manuf

15、acturers instructions.8.Procedure8.1 Pulverize pelleted or lumpy carbon black to a finepowder,using either the high speed mixer or mortar and pestle.8.2 Prepare boiling distilled water in a stainless steel beaker.8.3 Weigh carbon black and boiling distilled water into aglass beaker or boiling flask

16、and add 2 to 3 drops of acetone tofacilitate wetting of the sample.The carbon black weight andvolume of water is maintained at a constant ratio of 1:10.SeeTable 1 for selection of carbon black weight,volume of waterand beaker or boiling flask volume.NOTE3A stainless steel beaker is used to eliminate contaminationduring boiling.8.4 Cover the glass beaker with a watch glass and boil themixture for 15 min,but do not allow all the liquid to evaporate.8.5 Let the mixture cool to room temperature in a

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2