1、Designation:C636/C636M19Standard Practice forInstallation of Metal Ceiling Suspension Systems forAcoustical Tile and Lay-In Panels1This standard is issued under the fixed designation C636/C636M;the number immediately following the designation indicates the yearof original adoption or,in the case of

2、revision,the year of last revision.A number in parentheses indicates the year of last reapproval.A superscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice covers the installation of suspension sys-tems for acoustical tile and lay-in panels.It

3、 is applicable tocontractors whose services are utilized for installing acousticalceilings and to other trades if their activities are responsible forinterference with ceiling components or performance as de-fined in this recommended practice.1.2 While the practices described in this document haveeq

4、ual application to fire-resistive suspension systems,manysystems impose additional requirements to obtain the fireendurance classification of particular floor-ceiling or roof-ceiling assemblies.These details are available from the listingagency and from the manufacturers.1.3 Similarly,additional det

5、ailing is often necessary to meetsound attenuation requirements when ceiling plenums extendover contiguous rooms.Obtain these from the manufacturer ofthe acoustical material employed.1.4 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard.The values stat

6、ed ineach system are not exact equivalents;therefore,each systemshall be used independently of the other.Combining valuesfrom the two systems result in non-conformance with thestandard.1.5 While many of the practices described in this practicehave application to the installation of metal suspension

7、systemsin exterior environments,the specific design of exterior ceilinginstallations requires the review and approval of the architector engineer,or both,who are responsible for the constructionof the building or modifications to an existing building.Whilerecommendations from the manufacturer are so

8、licited,it re-mains the final responsibility of the architect/engineer to ensureproper application of the materials in question.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish app

9、ro-priate safety,health,and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDev

10、elopment of International Standards,Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade(TBT)Committee.2.Installation of Components2.1 Hangers:2.1.1 Where acoustical ceilings are suspended from a struc-ture of wood construction,attach hangers with suitable me

11、-chanical devices either to the bottom edge of the wood joists orto the vertical face of the wood joists near the bottom edge.Holding power tests certified by the manufacturer must beavailable on request for bottom edge attachment devices.2.1.2 Where acoustical ceilings are suspended from a struc-tu

12、re of concrete construction,mount hangers using cast-in-place hanger wires,hanger inserts,or other hanger attachmentdevices whose suitability has been demonstrated by standardconstruction practice or by certified test data.2.1.3 Space hangers for carrying channels or main runners 4ft 0 in.1200 mm on

13、 centers.If local situations allow greatercenter distances between hangers,reduce the load-carryingcapacity of the ceiling suspension system commensurate withthe actual center-to-center hanger distances used.If localsituations allow lesser center distances between hangers,in-crease the load-carrying

14、 capacity of the ceiling suspensionsystem commensurate with the actual center-to-center hangerdistances used.2.1.4 Each suspension wire shall not hang more than one insix out of plumb unless a countersloping wire or horizontalbracing is provided.See Fig.1 for allowable counterslopingmethods.Suspensi

15、on wires shall not press against ducts orpipes.2.1.5 Hangers formed from galvanized sheet metal stockshall be suitable for suspending carrying channels or mainrunners from an existing structure provided that the hangers donot yield,twist,or undergo other objectionable movement.2.1.6 Wire hangers for

16、 suspending carrying channels ormain runners from an existing structure shall be prepared from1This practice is under the jurisdiction of ASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.04 on Application of Acoustical Materials and Systems.Current edition approved April 1,2019.Published May 2019.Originallyapproved in 1969.Last previous edition approved in 2013 as C636/C636M 13.DOI:10.1520/C0636_C0636M-19.Copyright ASTM International,1