1、Designation:D224715Standard Practice forTesting Water Resistance of Coatings in 100%RelativeHumidity1This standard is issued under the fixed designation D2247;the number immediately following the designation indicates the year oforiginal adoption or,in the case of revision,the year of last revision.

2、A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S.Department of Defense.1.Scope*1.1 This practice covers the basic principles and opera

3、tingprocedures for testing water resistance of coatings by exposingcoated specimens in an atmosphere maintained at 100%relative humidity so that condensation forms on all surfaces oftest specimens.1.2 This practice uses the technique of creating a slighttemperature differential within the exposure a

4、rea to formcondensation on the coated specimens.As the warmer satu-rated air passes the cooler specimens,water is deposited ontothe specimens in the form of condensation.1.3 This practice places the entire specimen in the exposurearea allowing condensation to form on all surfaces.This makesthis prac

5、tice suitable for flat panels as well as large or 3Dobjects.This practice differs from other methods where con-densation is only formed on the front coating surface,while theback surface is outside the exposure area.Other tests may alsodeposit water droplets on the surface but where the source isnot

6、 from condensation(for example,water spray).NOTE1Alternative practices for testing the water resistance ofcoatings include Practices D870,D1735,and D4585.1.4 This practice is limited to the methods of obtaining,measuring,and controlling the conditions and procedures oftests conducted in 100%relative

7、 humidity.It does not specifyspecimen preparation,or evaluation of results.1.5 The values stated in SI units are to be regarded as thestandard.The values given in parentheses are for informationonly.1.6 This standard does not purport to address all of thesafety concerns,if any,associated with its us

8、e.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2D609 Practice for Preparation of Cold-Rolled Steel Panelsfor Testing Paint,Va

9、rnish,Conversion Coatings,andRelated Coating ProductsD610 Practice for Evaluating Degree of Rusting on PaintedSteel SurfacesD714 Test Method for Evaluating Degree of Blistering ofPaintsD823 Practices for Producing Films of Uniform Thicknessof Paint,Varnish,and Related Products on Test PanelsD870 Pra

10、ctice for Testing Water Resistance of CoatingsUsing Water ImmersionD1193 Specification for Reagent WaterD1654 Test Method for Evaluation of Painted or CoatedSpecimens Subjected to Corrosive EnvironmentsD1730 PracticesforPreparationof AluminumandAluminum-Alloy Surfaces for PaintingD1735 Practice for

11、Testing Water Resistance of CoatingsUsing Water Fog ApparatusD2616 Test Method for Evaluation of Visual Color Differ-ence With a Gray ScaleD3359 Test Methods for Measuring Adhesion by Tape TestD3363 Test Method for Film Hardness by Pencil TestD4541 Test Method for Pull-Off Strength of Coatings Using

12、Portable Adhesion TestersD4585 Practice for Testing Water Resistance of CoatingsUsing Controlled Condensation3.Summary of Practice3.1 Coated specimens are placed in an enclosed chambercontaining a heated,saturated mixture of air and water vapor.The temperature of the chamber is usually maintained at

13、 38C(100F).At 100%relative humidity(RH),a very smalltemperature difference between the specimen and the surround-ing vapor causes the formation of condensation on the speci-mens.The exposure condition is varied by selecting the1This practice is under the jurisdiction of ASTM Committee D01 on Paint a

14、ndRelated Coatings,Materials,and Applications and is the direct responsibility ofSubcommittee D01.27 on Accelerated Testing.Current edition approved Dec.1,2015.Published December 2015.Originallyapproved in 1966.Last previous edition approved in 2011 as D2247 11.DOI:10.1520/D2247-15.2For referenced A

15、STM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM Int

16、ernational,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 duration of the test.Water permeates the coating at rates thatare dependent upon the characteristics of the coating.Anyeffects such as color change,blistering,loss of adhesion,softening,or embrittlement are observed and reported.4.Significance and Use4.1 Water can cause the degradation of coatings,so knowl-edge of how a coating resists water is helpful for assessing howit will perform in actual service.Fa

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2