收藏 分享(赏)

ASTM_C_1428_-_11.pdf

上传人:益****师 文档编号:184620 上传时间:2023-03-04 格式:PDF 页数:4 大小:88.74KB
下载 相关 举报
ASTM_C_1428_-_11.pdf_第1页
第1页 / 共4页
ASTM_C_1428_-_11.pdf_第2页
第2页 / 共4页
ASTM_C_1428_-_11.pdf_第3页
第3页 / 共4页
ASTM_C_1428_-_11.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:C142811Standard Test Method forIsotopic Analysis of Uranium Hexafluoride bySingleStandard Gas Source Multiple Collector MassSpectrometer Method1This standard is issued under the fixed designation C1428;the number immediately following the designation indicates the year oforiginal adoptio

2、n or,in the case of revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method is applicable to the isotopic analysis ofuranium hexafluoride(UF6

3、)with235U concentrations less thanor equal to 5%and234U,236U concentrations of 0.0002 to0.1%.1.2 This test method may be applicable to the analysis of theentire range of235U isotopic compositions providing thatadequate Certified Reference Materials(CRMs or traceablestandards)are available.1.3 This s

4、tandard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety health practices and determine the applicability ofregulatory limitations prior to use.2.Referenced Documents2.1 ASTM Sta

5、ndards:2C787 Specification for Uranium Hexafluoride for Enrich-mentC996 Specification for Uranium Hexafluoride Enriched toLess Than 5%235U2.2 Other Document:USEC-651Uranium Hexafluoride:A Manual of GoodHandling Practices33.Summary of Test Method3.1 The unknown sample and a CRM or traceable standardw

6、hose isotopic composition is close to that of the sample areintroduced in sequence into the mass spectrometer,and234U,235U,236U,and238U ions are focused through correspondingcollector slits to the four separate collectors.Measurements aremade that are proportional to the ratios of234U,235U,or236Uto2

7、38U.With the known composition of the CRM or traceablestandard,these ratios of molar ratios permit calculation of the234U,235U,and236U contents.Memory corrections areapplied based on the periodic measurement of two CRMs ortraceable standards.4.Significance and Use4.1 Uranium hexafluoride is a basic

8、material used to pro-duce nuclear reactor fuel.To be suitable for this purpose,thematerial must meet criteria for isotopic composition.This testmethod is designed to determine whether the material meetsthe requirements described in Specifications C787 and C996.5.Apparatus5.1 A gas source multiple co

9、llector mass spectrometer withthe following attributes:5.1.1 The resolving power of the mass spectrometer is notless than 500.The resolving power(R)is calculated from theregistered mass spectrum of both the235UF5+and238UF5+isotopes as follows:R 5aMbDM(1)wherea=distance between centers of the235UF5+a

10、nd238UF5+peaks,b=peak width of the238UF5+isotope(10%valley),M=333 mass(u)238UF5+,andDM=3=333 330,330 mass(u)235UF5+5.1.2 The abundance sensitivity of the mass spectrometer isspecified as less than 1105as contribution of mass 333(238UF5+)to mass 331(236UF5+).5.1.3 The four collectors have collector s

11、lits adjusted forions of masses 329,330,331,and 333.Ion currents areamplified by four amplifiers,having noise level less than 0.5mV.5.1.4 The ion beams are kept within the slits by an auto-matic beam positioner circuit.1This test method is under the jurisdiction ofASTM Committee C26 on NuclearFuel C

12、ycle and is the direct responsibility of Subcommittee C26.05 on Methods ofTest.Current edition approved March 1,2011.Published April 2011.Originallyapproved in 1999.Last previous edition approved in 2005 as C142899(2005).DOI:10.1520/C1428-11.2For referenced ASTM standards,visit the ASTM website,www.

13、astm.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from United States Enrichment Corporation,6903 Rockledge Drive,Bethesda,MD 20817.Copyright ASTM International,100

14、 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 5.1.5 The pumping system of the mass spectrometer analy-ser tube shall maintain a pressure less than 5108torr with asample flowing into the ion source.5.1.6 The memory correction factor of the mass spectrom-eter as defined

15、 in 9.1 shall be consistent with the requiredaccuracy and precision,and shall not exceed 1.005.5.1.7 The sample inlet system shall be equipped with amanifold,including adjustable leak,and valves for introducingthe sample and CRM or traceable standard in sequence and forevacuating corresponding lines

16、.The pumping system of theinlet system must maintain a pressure less than 2102torr byevacuating.6.Hazards6.1 Since UF6is radioactive,toxic,and highly reactive,especially with reducing substances and moisture(see USEC-651),appropriate facilities and practices for analysis shall beprovided.7.Calibration and Standardization7.1 Uranium Hexafluoride Isotopic7.1.1 Two CRMs or traceable standards are used to deter-mine the memory correction factor.The235U concentrationratio of upper CRM or traceable st

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 专业资料 > 国外标准

copyright@ 2008-2023 wnwk.com网站版权所有

经营许可证编号:浙ICP备2024059924号-2