收藏 分享(赏)

ASTM_C_1107_-_C_1107M_-_14a.pdf

上传人:益****师 文档编号:185056 上传时间:2023-03-04 格式:PDF 页数:6 大小:103.21KB
下载 相关 举报
ASTM_C_1107_-_C_1107M_-_14a.pdf_第1页
第1页 / 共6页
ASTM_C_1107_-_C_1107M_-_14a.pdf_第2页
第2页 / 共6页
ASTM_C_1107_-_C_1107M_-_14a.pdf_第3页
第3页 / 共6页
ASTM_C_1107_-_C_1107M_-_14a.pdf_第4页
第4页 / 共6页
ASTM_C_1107_-_C_1107M_-_14a.pdf_第5页
第5页 / 共6页
ASTM_C_1107_-_C_1107M_-_14a.pdf_第6页
第6页 / 共6页
亲,该文档总共6页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Designation:C1107/C1107M14aStandard Specification forPackaged Dry,Hydraulic-Cement Grout(Nonshrink)1This standard is issued under the fixed designation C1107/C1107M;the number immediately following the designation indicates the yearof original adoption or,in the case of revision,the year of last rev

2、ision.A number in parentheses indicates the year of last reapproval.A superscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope*1.1 This specification covers packaged dry,hydraulic ce-ment grout(nonshrink)intended for use under applied load(such as to support a

3、 structure,a machine,and the like)wherea change in height below initial placement height is to beavoided.1.2 Grouts covered are composed of hydraulic cement,fineaggregate,and other ingredients.They require only the addi-tion of mixing water for use.1.3 The values stated in either SI units or inch-po

4、und unitsare to be regarded separately as standard.The values stated ineach system may not be exact equivalents;therefore,eachsystem shall be used independently of the other.Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 The following safety hazards caveat pe

5、rtains only to thetest method portion of this specification:This standard doesnot purport to address all of the safety concerns,if any,associated with its use.It is the responsibility of the user of thisstandard to establish appropriate safety and health practicesand determine the applicability of r

6、egulatory limitations priorto use.2.Referenced Documents2.1 ASTM Standards:2C109/C109M Test Method for Compressive Strength ofHydraulic Cement Mortars(Using 2-in.or 50-mm CubeSpecimens)C125 Terminology Relating to Concrete and Concrete Ag-gregatesC138/C138M Test Method for Density(Unit Weight),Yield

7、,and Air Content(Gravimetric)of ConcreteC157/C157M Test Method for Length Change of HardenedHydraulic-Cement Mortar and ConcreteC185 Test Method for Air Content of Hydraulic CementMortarC305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC702 Practice for

8、Reducing Samples ofAggregate to TestingSizeC827 Test Method for Change in Height at Early Ages ofCylindrical Specimens of Cementitious MixturesC939 Test Method for Flow of Grout for Preplaced-Aggregate Concrete(Flow Cone Method)C1090 Test Method for Measuring Changes in Height ofCylindrical Specimen

9、s of Hydraulic-Cement GroutC1437 Test Method for Flow of Hydraulic Cement Mortar3.Terminology3.1 DefinitionsFor definitions of terms used in thisspecification,refer to Terminology C125.3.2 Definitions of Terms Specific to This Standard:3.2.1 consistency,flowable,na grout consistency having aflow of

10、125 to 145 by the flow test in accordance with theapplicable provisions of Test Method C1437;the flow after 5drops of the flow table in 3 s.3.2.2 consistency,fluid,na grout consistency having atime of efflux of 10 to 30 s when tested by the flow coneprocedure of Test Method C939.3.2.3 consistency,pl

11、astic,na grout consistency having aflow of 100 to 125 by the flow test in accordance with theapplicable provisions of Test Method C1437;the flow after 5drops of the flow table in 3 s.4.Ordering Information4.1 When the purchaser specifies that properties of thepackaged,dry grout meet the requirements

12、 of this specification,also specify which,if any,of the optional requirements apply.4.2 When the grout is to be used in contact with stressedtendons or other corrosion-sensitive,load-bearing structuralmembers,the purchaser shall supply this information to themanufacturer and obtain assurances that t

13、he material meetsrelevant chloride,nitrite,nitrate,sulfide,and sulfaterequirements,and any other material limitations imposed bythe applicable codes and standards(see Note 1).1This specification is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregatesand is the direct respo

14、nsibility of SubcommitteeC09.43 on Packaged Dry Combined Materials.Current edition approved Dec.15,2014.Published March 2015.Originallyapproved in 1991.Last previous edition approved in 2014 as C1107/C1107M 14.DOI:10.1520/C1107_C1107M-14A.2For referenced ASTM standards,visit the ASTM website,www.ast

15、m.org,orcontact ASTM Customer Service at serviceastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International,100 Barr Harbor Drive,PO Box C700

16、,West Conshohocken,PA 19428-2959.United States1 4.3 When the grout is to be used in abnormal or aggressiveenvironments,the purchaser shall supply this information tothe manufacturer and obtain assurance that the grout has asuccessful history of performance in the same or similarexposures.NOTE1Since all conditions of use cannot be anticipated,thisspecification requires nonshrink grout to exhibit no shrinkage when testedin a laboratory-controlled,moist-cured environment,and requires only thereport