1、Designation:B7690(Reapproved 2013)Standard Test Method forAccelerated Life of Nickel-Chromium and Nickel-Chromium-Iron Alloys for Electrical Heating1This standard is issued under the fixed designation B76;the number immediately following the designation indicates the year of originaladoption or,in t

2、he case of revision,the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This test method2covers the determination of theresistance to oxidation of nickel-chromium an

3、d nickel-chromium-iron electrical heating alloys at elevated tempera-tures under intermittent heating.Procedures for a constant-temperature cycle are provided.This test method is used forinternal comparative purposes only.1.2 The values stated in inch-pound units are to be regardedas standard.The va

4、lues given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to becom

5、e familiarwith all hazards including those identified in the appropriateMaterial Safety Data Sheet(MSDS)for this product/materialas provided by the manufacturer,to establish appropriatesafety and health practices,and determine the applicability ofregulatory limitations prior to use.2.Significance an

6、d Use2.1 This test method is used by producers of electricalheating alloys to measure the cyclic oxidation resistance ofthese alloys.2.2 Because of the effect of the environment,design,anduse,the life values obtained from this test method may notcorrelate with that of an appliance or industrial heat

7、ing unit.3.Test Panel3.1 Size and LocationThe dimensions of the test panelshall be similar to those shown in Fig.1.The test panel shall belocated in a position free from drafts of air.NOTE1The enclosure shall fit tightly on the panel and the glass slideshall fit snugly to prevent leakage of air at t

8、his point during the operationof the test,as even a slight draft of air in contact with the specimen willcause excessive variation in length of life.A screen of 40 wire mesh,0.010-in.(0.025-mm)wire diameter,market grade,may be used as a coverover the individual stations.3.2 Upper TerminalThe upper t

9、erminal shall consist of abinding post attached to a rod passing through another bindingpost or through the upper bus bar.This provides for adjustmentlaterally and vertically,as shown in Fig.1.3.3 Lower TerminalA 10-g weight shall be attached to thelower end of the specimen.Aflexible silver foil(app

10、roximately0.375 in.(9.52 mm)wide and 0.0015 in.(0.038 mm)thick)connected to the 10-g weight shall constitute the lowerterminal.NOTE2Experiments have shown that with high temperatures alloys ofnickel-chromium and nickel-chromium-iron are subject to plastic flowwhen under relatively light load.The wei

11、ght specified in 3.3 does notcause appreciable increase in length during the test.4.Apparatus4.1 The test apparatus shall be similar to the requirementsspecified in 4.2 to 4.8,inclusive,and shall be connected asshown in Fig.2.4.2 Power SupplyThe transformer or motor generator setshall be capable of

12、delivering a controlled voltage of from 10to 20 V to the circuit.It shall have a continuous currentcapacity of at least 20 A/specimen.4.3 Voltage ControlThe automatic voltage control shall becapable of maintaining across the bus bars a constant voltagewithin 60.5%.NOTE3It has been found impossible t

13、o make accurate tests withoutvoltage control,as changes in line voltage were sufficient to causeconsiderable variation in the results obtained(see Annex A1).4.4 Variable TransformerThe transformer shall be capableof adjusting the voltage across the specimen so that current iscontrolled to approximat

14、ely 0.25%of desired value,and shallhave a continuous current rating of approximately 25 A.4.5 Ammeter and VoltmeterThe ammeter and voltmetershall have an accuracy of 1%of normal test deflection(approximately 15 A and 15 V,respectively).For alternatingcurrent the range used shall be such as to give a

15、 reading above1This test method is under the jurisdiction of ASTM Committee B02 onNonferrous Metals and Alloys and is the direct responsibility of SubcommitteeB02.10 on Thermostat Metals and Electrical Resistance Heating Materials.Current edition approved May 1,2013.Published May 2013.Originallyappr

16、oved in 1929.Last previous edition approved in 2007 as B76 90(2007).DOI:10.1520/B0076-90R13.2Further information on this test method is given in a paper by F.E.Bash andJ.W.Harsch,“Life Tests on Metallic Resistor Materials for Electrical Heating,”Proceedings,ASTEA,American Society for Testing and Materials.Vol 29,Part II,1929,p.506.Copyright ASTM International,100 Barr Harbor Drive,PO Box C700,West Conshohocken,PA 19428-2959.United States1 the lower fifth of the scale range.The ammeter has apprec