收藏 分享(赏)

ASTM_F_2567_-_06_2010.pdf

上传人:益****师 文档编号:189777 上传时间:2023-03-04 格式:PDF 页数:10 大小:333.68KB
下载 相关 举报
ASTM_F_2567_-_06_2010.pdf_第1页
第1页 / 共10页
ASTM_F_2567_-_06_2010.pdf_第2页
第2页 / 共10页
ASTM_F_2567_-_06_2010.pdf_第3页
第3页 / 共10页
ASTM_F_2567_-_06_2010.pdf_第4页
第4页 / 共10页
ASTM_F_2567_-_06_2010.pdf_第5页
第5页 / 共10页
ASTM_F_2567_-_06_2010.pdf_第6页
第6页 / 共10页
亲,该文档总共10页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

1、Designation:F256706(Reapproved 2010)Standard Practice forTesting for Classical Pathway Complement Activation inSerum by Solid Materials1This standard is issued under the fixed designation F2567;the number immediately following the designation indicates the year oforiginal adoption or,in the case of

2、revision,the year of last revision.A number in parentheses indicates the year of last reapproval.Asuperscript epsilon()indicates an editorial change since the last revision or reapproval.1.Scope1.1 This practice provides a protocol for rapid,in vitrofunctional screening for classical pathway complem

3、ent activat-ing properties of solid materials used in the fabrication ofmedical devices that will contact blood.1.2 This practice is intended to evaluate the acute in vitroclassical pathway complement activating properties of solidmaterials intended for use in contact with blood.For thispractice,“se

4、rum”is synonymous with“complement.”1.3 This practice consists of two procedural parts.Proce-dureAdescribes exposure of solid materials to a standard lot ofhuman serum HS,using 0.1 mL serum per 13100 mmdisposable glass test tube.Procedure B describes assaying theexposed serum for significant function

5、al classical pathwaycomplement depletion(decrease in amount of C4)as comparedto control serum samples not exposed to the material.Theendpoint in Procedure B is lysis of sheep red blood cells(RBC)coated with antibody(hemolysin).1.4 This practice does not address the use of plasma as asource of comple

6、ment.1.5 This practice is one of several developed for theassessment of the biocompatibility of materials.Practice F748may provide guidance for the selection of appropriate methodsfor testing materials for other aspects of biocompatibility.Practice F1984 provides guidance for testing solid materials

7、 forwhole complement activation in human serum,but does notdiscriminate between the classical or alternative pathway ofactivation.Practice F2065 provides guidance for testing solidmaterials for alternative pathway complement activation inserum.1.6 The values stated in SI units are to be regarded ass

8、tandard.No other units of measurement are included in thisstandard.1.7 This standard does not purport to address all of thesafety concerns,if any,associated with its use.It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the appli

9、ca-bility of regulatory limitations prior to use.2.Referenced Documents2.1 ASTM Standards:2F748 Practice for Selecting Generic Biological Test Methodsfor Materials and DevicesF1984 Practice for Testing for Whole Complement Activa-tion in Serum by Solid MaterialsF2065 Practice for Testing for Alterna

10、tive Pathway Comple-ment Activation in Serum by Solid Materials2.2 Other Document:ISO 10993-4 Biological Evaluation of Medical Devices,Part4:Selection of Tests for Interactions with Blood33.Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 waterdistilled,endotoxin-free.3.2 Abbrevia

11、tions:3.2.1 Abantibody(hemolysin)3.2.2 BBSbarbital buffered saline3.2.3 BBS-Gbarbital buffered salinegelatin3.2.4 BBS-GM(Ca Buffer)barbital buffered salinegelatinmetals3.2.5 Ccomplement3.2.6 C4the fourth component of complement3.2.7 C4(-)GPSC4-deficient guinea pig serum serumfrom guinea pigs genetic

12、ally incapable of producing C43.2.8 EDTAethylenediaminetetraacetic acid,disodiumsalt,dihydrate3.2.9 HAGGheat aggregated gamma globulin1This practice is under the jurisdiction ofASTM Committee F04 on Medical andSurgical Materials and Devices and is the direct responsibility of SubcommitteeF04.16 on B

13、iocompatibility Test Methods.Current edition approved Sept.1,2010.Published November 2010.Originallyapproved in 2006.Last previous edition approved in 2006 as F2567 06.DOI:10.1520/F2567-06R10.2For referenced ASTM standards,visit the ASTM website,www.astm.org,orcontact ASTM Customer Service at servic

14、eastm.org.For Annual Book of ASTMStandards volume information,refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute(ANSI),25 W.43rd St.,4th Floor,New York,NY 10036,http:/www.ansi.org.Copyright ASTM International,100 Barr Harbor Drive,PO

15、 Box C700,West Conshohocken,PA 19428-2959.United States1 3.2.10 HShuman serum3.2.11 I“ice”control tube with serum but no material,kept on ice3.2.12 Mtube containing serum plus a test material3.2.13 NMtube containing serum but no material3.2.14 RBCred blood cell(s)4.Summary of Practice4.1 This practi

16、ce is based on a method published by Gaitheret al,1974(1).44.2 Solid material specimens are exposed to a standard lotof human C(specially-prepared,commercial human serumHS)under defined conditions,in parallel with appropriatecontrols(Procedure A).If the classical complement pathway isactivated by the material,C4 will be depleted from the serum.Exposed serum is then tested for remaining C4 functionalactivity.An appropriate dilution of the HS,which by itself istoo dilute to lyse sensitized sheep R