1、?Surface and Dermal SamplingJAI Guest Editors:Michael BrissonKevin Ashley?Surface and Dermal SamplingJAI Guest Editors:Michael BrissonKevin Ashley?Surface and Dermal SamplingJAI Guest Editors:Michael BrissonKevin Ashley Journal of ASTM International Selected Technical Papers STP1533Surface and Derma
2、l SamplingJAI Guest Editors:Michael BrissonKevin AshleyASTM International100 Barr Harbor DrivePO Box C700West Conshohocken,PA 19428-2959Printed in the U.S.A.ASTM Stock#:STP1533 Library of Congress Cataloging-in-Publication DataISBN:978-0-8031-7519-8Copyright 2011 ASTM INTERNATIONAL,West Conshohocken
3、,PA.All rights reserved.This material may not be reproduced or copied,in whole or in part,in any printed,mechanical,electronic,fi lm,or other distribution and storage media,without the written consent of the publisher.Journal of ASTM International(JAI)ScopeThe JAI is a multi-disciplinary forum to se
4、rve the international scientifi c and engineering community through the timely publication of the results of original research and critical review articles in the physical and life sciences and engineering technologies.These peer-reviewed papers cover diverse topics relevant to the science and resea
5、rch that establish the foundation for standards development within ASTM International.Photocopy RightsAuthorization to photocopy items for internal,personal,or educational classroom use,or the internal,personal,or educational classroom use of specifi c clients,is granted by ASTM International provid
6、ed that the appropriate fee is paid to ASTM International,100 Barr Harbor Drive,P.O.Box C700,West Conshohocken,PA 19428-2959,Tel:610-832-9634;online:http:/www.astm.org/copyright.The Society is not responsible,as a body,for the statements and opinions expressed in this publication.ASTM International
7、does not endorse any products represented in this publication.Peer Review PolicyEach paper published in this volume was evaluated by two peer reviewers and at least one editor.The authors addressed all of the reviewers comments to the satisfaction of both the technical editor(s)and the ASTM Internat
8、ional Committee on Publications.The quality of the papers in this publication refl ects not only the obvious efforts of the au-thors and the technical editor(s),but also the work of the peer reviewers.In keeping with long-standing publication practices,ASTM International maintains the anonymity of t
9、he peer reviewers.The ASTM International Committee on Publications acknowledges with appreciation their dedication and contribution of time and effort on behalf of ASTM International.Citation of PapersWhen citing papers from this publication,the appropriate citation includes the paper authors,“paper
10、 title”,J.ASTM Intl.,volume and number,Paper doi,ASTM International,West Conshohocken,PA,Paper,year listed in the footnote of the paper.A citation is provided as a footnote on page one of each paper.Printed in Baltimore,MD November,2011 ForewordTHIS COMPILATION OF THE JOURNAL OF ASTM INTERNATIONAL(J
11、AI),STP1533,on Surface and Dermal Sampling contains only the papers published in JAI that were presented at a symposium in San Antonio,TX,on 14-15 October 2010 and sponsored by ASTM Committee D22 on Air Quality and subcommittee D22.04 on Workplace Air Quality.The Symposium Chairs and JAI Guest Edito
12、rs are Michael Brisson,Savannah River Nuclear Solutions LLC,Aiken,SC and Kevin Ashley,Centers for Disease Control/National Institute for Occupational Safety and Health(NIOSH),Cincinnati,OH.ContentsOverview.viiAcknowledgments.xStandardization IssuesReview of Standards for Surface and Dermal SamplingK
13、.Ashley,M.J.Brisson,and K.T.White.3Derivation of Health-Based Screening Levels for Evaluating Indoor Surface ContaminationG.Murnyak and H.-Y.Chang.17Indoor Allergen Surface Sampling Methods and Standards:A Review of the TheoryR.D.Lewis and D.Chen.34DermalEvaluation of a Handwipe Disclosing Method fo
14、r LeadK.Ashley,T.J.Wise,and E.J.Esswein.57Handwipe Method for Removing Lead from SkinE.J.Esswein,M.F.Boeniger,and K.Ashley.67LeadDevelopment of Two Sample Preparation Methods for Determination of Lead in Composite Dust Wipe SamplesK.T.White,F.G.Dewalt,D.C.Cox,R.Schmehl,W.Friedman,and E.A.Pinzer.85Im
15、proving the Confi dence Level in Lead Clearance Examination Results through Modifi cations to Dust Sampling ProtocolsD.C.Cox,F.G.Dewalt,K.T.White,R.Schmehl,W.Friedman,and E.A.Pinzer.101Pilot Evaluation for Lead-Based Paint Profi ciency Testing of Field-Portable XRF InstrumentsK.T.White,F.G.Dewalt,D.
16、C.Cox,R.Schmehl,W.Friedman,and E.A.Pinzer.118BerylliumBeryllium Measurement by Optical Fluorescence in Samples Contaminated byStrongly Fluorescent ImpuritiesA.Agrawal,L.Adams,A.Agrawal,J.P.Cronin,J.C.Lopez Tonazzi,and B.Duran.127Beryllium Measurement in Commercially Available Wet WipesL.D.Youmans-McDonald,M.J.Brisson,M.Bernard,A.Agrawal,J.P.Cronin,and L.Adams.141The Feasibility of Studying the Health Implications of Surface Beryllium Contamination:A Review of Eight IndustriesM.McCawley.151 Asbes