1、Manual on Coating and Lining Methods for Cooling Water Systems in Power Plants John C.Monday,Timothy B.Shugart,and Joseph A.Tamayo ASTM Manual Series:MNL 28 ASTM Publication Code Number(PCN)28-028095-14 100 Ban-Harbor Drive West Conshohocken,PA 19428-2959 Library of Congress Cataloging-in-Publicatlo
2、n Data Manual on coating and lining work for power plant cooling water systems/sponsored by ASTM Committee D-33 on Protective Coating and Lining Work for Power Generation facilities;prepared by ASTM Sub-Committee D33.12 on Service and Circulating Cooling Water Systems,p.cm.(ASTM manual series;MNL 28
3、)Includes bibliographical references and Index.ISBN 0-8031-2070-2 1.Cooling towersHandbooks,manuals,etc.2.Power palnts-CoolIngHandbooks,manuals,etc.I.ASTM Sub-Committee D-33.12 on Service and Circulating Cooling Water Systems.II.Series.TJ563.M15 1995 621.197dc20 95-43136 CIP Copyright*1995 AMERICAN
4、SOCIETY FOR TESTING AND MATERIALS.All rights reserved.This material may not be reproduced or copied in whole or in part,m any printed,mechanical,electronic,fihn,or other distribution and storage media,without the written consent of the publisher.Photocopy Rights Authorization to photocopy items for
5、internal or personal use,or the internal or personal use of specific clients,is granted by the AMERICAN SOCIETY FOR TESTING AND MATERIALS for users registered with the Copyright Clearance Center(CCC)Transactional Reporting Service,provided that the base fee of$2.50 per copy,plus$0.50 per page is pai
6、d directly to CCC,27 Congress St.,Salem,MA 01970;(508)744-3350.For those organizations that have been granted a photocopy license by CCC,a separate system of payment has been arranged.The fee code for users of the Transactional Reporting Service is 0-8031-2070-2 95$2.50+.50.NOTE:This manual does not
7、 purport to address(all of)the safety problems associated with its use.It is the responsiblity of the user of this manual to establish appropriate safety and health practices and determine the applicability of regulatory limitations pu-ior to use.Printed in Philadelphia November,1995 Foreword The AS
8、TM Manual on Coating and Lining Methods for Cooling Water Systems in Power Plants(MNL 28)is sponsored by ASTM Committee D-33 on Protective Coating and Lining Work for Power Generation Facilities.This manual was prepared by ASTM Sub-Committee D-33.12 on Service and Circulating Cooling Water Systems.J
9、ohn C.Monday,Timothy B.Shugart,and Joseph A.Tamayo served as the editors of this publication.CITED ASTM STANDARDS B-117 Test Method of Salt Spray(Fog)Testing C-868 Test Method for Chemical Resistance of Protective Linings D-256 Test Method for Determining the Pendulum Impact Resistance of Notched Sp
10、ecimens of Plastics D-412 Test Methods for Vulcanized Rubber and Thermoplastic Rubbers and Thermoplastic Elastomers-Tension D-429 Test Methods for Rubber Property-Adhesion to Rigid Substrates D-610 Test Method for Evaluating Degree of Rusting on Painted Steel Surfaces D-624 Test Method for Tear Stre
11、ngth of Conventional Vulcanized Rubber and Thermoplastic Elastomer D-638 Test Method for Tensile Properties of Plastics D-695 Test Method for Compressive Properties of Rigid Plastics D-696 Test Method for Coefficient of Linear Thermal Expansion of Plastics D-790 Test Methods for Flexural Properties
12、of Unreinforced and Reinforced Plastics and Electrical Insulating Materials D-968 Test Merthod for Abrasion Resistance of organic Coatings by Falling Abrasive D-1002 Test Method for Apparent Shear Strengfth of Single-Lap-Joint Adhesively Bonded Metal Specimens by Tension Loading(Metal-to-Metal)D-124
13、2 Test Methods for Resistance of Plastic Materials to Abrasion D-1653 Test Method for Water Vapor Transmission of Organic Coating Films D-2240 Test Method for Rubber PropertyDurometer Hardness D-2305 Test Methods for Polymeric Films Used for Electrical Insulation D-3843 Practice for Quality Assuranc
14、e for Protective Coatings Applied to Nuclear Facilities D-3912 Test Method for Chemical Resistance of Coatings Used in Light-Water Nuclear Power Plants D-4060 Test Method for Abrasion Resistance of Organic Coatings by the Taber Abraser D-4263 Test Method for Indicating Moisture in Concrete by the Pl
15、astic Sheet Method D-4285 Method for Indicating Oil or Water in Compressed Air D-4541 Method for Pull-Off Strength of Coatings Using Portable Adhesion-Testers E-96 Test Methods for Water Vapor Transmission of Materials F-1249 Test Method for Water Vapor Transmission Rate Through Plastic Film and She
16、eting Using a Modulated Infrared Sensor G-8 Test Method for Cathodic Disbonding of Pipeline Coatings G-14 Test Method for Impact Resistance of Pipeline Coatings(Falling Weight Test)TABLE OF CONTENTS Chapter INTRODUCTION 11 1.1 2.1 3.1 4.1 5.1 6.1 7.1 8.1 9.1 10.1 I List of Key Questions AI.l(for general evaluation of service conditions)II Coating Selection Chart(generic coatings typically used,and whioch may be considered for the various cooling water system components)III Suggested Test Methods