1、NORMEINTERNATIONALEINTERNATIONALSTANDARDCEIIEC1084-2-4Premire ditionFirst edition1996-04Systme de goulottes et de conduits profilspour installations lectriques Partie 2:Rgles particulires Section 4:Colonnes de serviceCable trunking and ducting systemsfor electrical installations Part 2:Particular re
2、quirements Section 4:Service polesIECNumro de rfrenceReference numberCEI/IEC 1084-2-4:1996LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.Validit de la prsente publicationLe contenu technique des publications de la CEI est cons-tamment
3、 revu par la CEI afin quil reflte ltat actuel dela technique.Des renseignements relatifs la date de reconfirmation dela publication sont disponibles auprs du Bureau Central dela CEI.Les renseignements relatifs ces rvisions,ltablis-sement des ditions rvises et aux amendements peuventtre obtenus auprs
4、 des Comits nationaux de la CEI etdans les documents ci-dessous:Bulletin de la CEIAnnuaire de la CEIPubli annuellementCatalogue des publications de la CEIPubli annuellement et mis jour rgulirementTerminologieEn ce qui concerne la terminologie gnrale,le lecteur sereportera la CEI 50:Vocabulaire Elect
5、rotechnique Inter-national(VEI),qui se prsente sous forme de chapitresspars traitant chacun dun sujet dfini.Des dtailscomplets sur le VEI peuvent tre obtenus sur demande.Voir galement le dictionnaire multilingue de la CEI.Les termes et dfinitions figurant dans la prsente publi-cation ont t soit tirs
6、 du VEI,soit spcifiquementapprouvs aux fins de cette publication.Symboles graphiques et littrauxPour les symboles graphiques,les symboles littraux et lessignes dusage gnral approuvs par la CEI,le lecteurconsultera:la CEI 27:Symboles littraux utiliser en lectro-technique;la CEI 417:Symboles graphique
7、s utilisables sur lematriel.Index,relev et compilation des feuillesindividuelles;la CEI 617:Symboles graphiques pour schmas;et pour les appareils lectromdicaux,la CEI 878:Symboles graphiques pour quipementslectriques en pratique mdicale.Les symboles et signes contenus dans la prsente publi-cation on
8、t t soit tirs de la CEI 27,de la CEI 417,de laCEI 617 et/ou de la CEI 878,soit spcifiquement approuvsaux fins de cette publication.Publications de la CEI tablies par lemme comit dtudesLattention du lecteur est attire sur les listes figurant la finde cette publication,qui numrent les publications de
9、laCEI prpares par le comit dtudes qui a tabli laprsente publication.Validity of this publicationThe technical content of IEC publications is kept underconstant review by the IEC,thus ensuring that the contentreflects current technology.Information relating to the date of the reconfirmation of thepub
10、lication is available from the IEC Central Office.Information on the revision work,the issue of revisededitions and amendments may be obtained from IECNational Committees and from the following IECsources:IEC BulletinIEC YearbookPublished yearlyCatalogue of IEC publicationsPublished yearly with regu
11、lar updatesTerminologyFor general terminology,readers are referred to IEC 50:International Electrotechnical Vocabulary(IEV),which isissued in the form of separate chapters each dealingwith a specific field.Full details of the IEV will besupplied on request.See also the IEC MultilingualDictionary.The
12、 terms and definitions contained in the present publi-cation have either been taken from the IEV or have beenspecifically approved for the purpose of this publication.Graphical and letter symbolsFor graphical symbols,and letter symbols and signsapproved by the IEC for general use,readers are referre
13、d topublications:IEC 27:Letter symbols to be used in electricaltechnology;IEC 417:Graphical symbols for use onequipment.Index,survey and compilation of thesingle sheets;IEC 617:Graphical symbols for diagrams;and for medical electrical equipment,IEC 878:Graphical symbols for electromedicalequipment i
14、n medical practice.The symbols and signs contained in the present publicationhave either been taken from IEC 27,IEC 417,IEC 617and/or IEC 878,or have been specifically approved for thepurpose of this publication.IEC publications prepared by the sametechnical committeeThe attention of readers is draw
15、n to the end pages of thispublication which list the IEC publications issued by thetechnical committee which has prepared the presentpublication.LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.NORME?CEIINTERNATIONALE?IECINTERNATIONAL?1
16、084-2-4STANDARDSystme de goulottes et de conduits profilspour installations lectriques Partie 2:Rgles particulires Section 4:Colonnes de serviceCable trunking and ducting systemsfor electrical installations Part 2:Particular requirements Section 4:Service poles CEI 1996 Droits de reproduction rservs Copyright all rights reservedPremire ditionFirst edition1996-04Aucune partie de cette publication ne peut tre reproduite niutilise sous quelque forme que ce soit et par aucun pro-cd,lectronique ou mc