1、INTERNATIONALSTANDARDIEC61223-2-10First edition1999-09Evaluation and routine testing inmedical imaging departments Part 2-10:Constancy tests X-ray equipment for mammographyEssais dvaluation et de routine dansles services dimagerie mdicale Partie 2-10:Essais de constance Equipements de mammographieRe
2、ference numberIEC 61223-2-10:1999(E)LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.NumberingAs from 1 January 1997 all IEC publications are issued with a designation in the60000 series.Consolidated publicationsConsolidated versions of
3、 some IEC publications including amendments areavailable.For example,edition numbers 1.0,1.1 and 1.2 refer,respectively,to thebase publication,the base publication incorporating amendment 1 and the basepublication incorporating amendments 1 and 2.Validity of this publicationThe technical content of
4、IEC publications is kept under constant review by the IEC,thus ensuring that the content reflects current technology.Information relating to the date of the reconfirmation of the publication is availablein the IEC catalogue.Information on the subjects under consideration and work in progress underta
5、kenby the technical committee which has prepared this publication,as well as the listof publications issued,is to be found at the following IEC sources:IEC web site*Catalogue of IEC publicationsPublished yearly with regular updates(On-line catalogue)*IEC BulletinAvailable both at the IEC web site*an
6、d as a printed periodicalTerminology,graphical and letter symbolsFor general terminology,readers are referred to IEC 60050:InternationalElectrotechnical Vocabulary(IEV).For graphical symbols,and letter symbols and signs approved by the IEC forgeneral use,readers are referred to publications IEC 6002
7、7:Letter symbols to beused in electrical technology,IEC 60417:Graphical symbols for use on equipment.Index,survey and compilation of the single sheets and IEC 60617:Graphical symbolsfor diagrams.*See web site address on title page.LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS L
8、OCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.INTERNATIONALSTANDARDIEC61223-2-10First edition1999-09Evaluation and routine testing inmedical imaging departments Part 2-10:Constancy tests X-ray equipment for mammographyEssais dvaluation et de routine dansles services dimagerie mdicale Partie 2-10:Essai
9、s de constance Equipements de mammographiePRICE CODE IEC 1999 Copyright-all rights reservedNo part of this publication may be reproduced or utilized in any form or by any means,electronic ormechanical,including photocopying and microfilm,without permission in writing from the publisher.International
10、 Electrotechnical Commission3,rue de Varemb Geneva,SwitzerlandTelefax:+41 22 919 0300e-mail:inmailiec.ch IEC web site http:/www.iec.chVFor price,see current catalogue Commission Electrotechnique Internationale International Electrotechnical CommissionLICENSED TO MECON Limited.-RANCHI/BANGALOREFOR IN
11、TERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.2 61223-2-10 IEC:1999(E)CONTENTSPageFOREWORD.3INTRODUCTION.5Clause1Scope and object.61.1Scope.61.2Object.62Normative references.73Terminology.73.1Degree of requirements.73.2Use of terms.83.3Definitions.84General aspects of CONSTANCY TES
12、TS.84.1General conditions affecting test procedures.84.2Establishment of BASELINE VALUES.94.3Frequency of CONSTANCY TESTS.94.4Identification of equipment,instrumentation and test conditions.95Performance tests.105.1X-RAY EQUIPMENT Imaging performance.105.2RADIATION BEAM Geometric characteristics.145
13、.3COMPRESSION DEVICE.155.4Mammographic cassettes and INTENSIFYING SCREENS.165.5Mammographic film.196Statement of compliance.20Annex A(normative)Terminology Index of defined terms.24Annex B(informative)Example of a form for the standardized test report.26Annex C(informative)Guidance on action to be t
14、aken.28Annex D(informative)Rationale.29Annex E(informative)Bibliography(informative).31Annex F(normative)PHANTOMS and TEST DEVICES.32Figure 1 ATTENUATION PHANTOM.21Figure 2 High-contrast TEST DEVICE.22Figure 3 Alternative high-contrast TEST DEVICE.23LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INT
15、ERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.61223-2-10 IEC:1999(E)3 INTERNATIONAL ELECTROTECHNICAL COMMISSION_EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS Part 2-10:Constancy tests X-ray equipment for mammographyFOREWORD1)The IEC(International Electrotechnical Com
16、mission)is a worldwide organization for standardization comprisingall national electrotechnical committees(IEC National Committees).The object of the IEC is to promoteinternational co-operation on all questions concerning standardization in the electrical and electronic fields.Tothis end and in addition to other activities,the IEC publishes International Standards.Their preparation isentrusted to technical committees;any IEC National Committee interested in the subject dealt with mayparticipate