1、January 2012 Janvier 2012 IEC 60079-11(Sixth edition 2011)Explosive atmospheres Part 11:Equipment protection by intrinsic safety“I”CEI 60079-11(Sixime dition 2011)Atmosphres explosives Partie 11:Protection de lquipement par scurit intrinsque i C O R R I G E N D U M 1 Changes to the French version ap

2、pear further in the document.Table 1 Applicability of specific clauses of IEC 60079-0 Replace existing row 26.4.4 by the following new row:26.4.4 26.4.4 Acceptance criteria Applies Applies Excluded except when 6.1.2.3a)is applied Table 3 Temperature classification of tracks on printed circuit boards

3、(in a maximum ambient temperature of 40 C)Replace the eighth footnote by the following new footnote:At terminations of components dissipating 0,25 W or more either normally or under fault conditions,and for 1,00 mm along the conductor,either multiply the track width by 3 or divide the maximum curren

4、t specified by 2.Additionally,if the track goes under the component,apply the factor specified for tracks passing under components dissipating 0,25W or more.Figure 1 Separation of intrinsically safe and non-intrinsically safe terminals Replace the drawing in Figure 1b by the following drawing:d1 d2

5、d3 d4 T T I.S.Circuit I.S.Circuit Non I.S.Circuit 1 2 IEC 001/12 8.2.3 Transformer construction Replace the existing fourth paragraph by the following new paragraph:January 2012 Janvier 2012 For type 2 construction,the windings shall be wound one over another with either a)solid insulation in accord

6、ance with Table 5 between the windings,or b)an earthed screen(made of copper foil)between the windings or an equivalent wire winding(wire screen).The thickness of the copper foil or the wire screen shall be in accordance with Table 6.12.1 General Replace the existing fifth and sixth paragraphs by th

7、e following new paragraphs:In the case of apparatus meeting the requirements of 6.1.2.3 a),the IP rating shall be marked.In the case of apparatus meeting the requirements of 6.1.2.3 c),the certificate number shall include the“X”suffix in accordance with the marking requirements of IEC 60079-0 and th

8、e specific conditions of use listed on the certificate shall detail the requirements.Replace the existing eighth paragraph by the following new paragraph:Where it is necessary to protect the apparatus from external physical impact in order to prevent the impact energy of 10.7 exceeding the specified

9、 values,details of the requirements shall be specified as special conditions for safe use and the certificate number shall include the“X”suffix in accordance with the marking requirements of IEC 60079-0 and the specific conditions of use listed on the certificate shall detail the requirements.Figure

10、 D.3a Moulding over un-mounted components Replace the existing drawing by the following new drawing:1 2 IEC 002/12 Figure G.1 Typical system Replace the existing drawing by the following new drawing:January 2012 Janvier 2012 U 2 3 1 6 4 5 7 1 N o n-h a z a r d o u s a r e a H a z a r d o u s a r e a

11、 U I IEC 003/12 January 2012 Janvier 2012 Tableau 1 Applicabilit des articles spcifiques de la CEI 60079-0 Remplacer la ligne existante 26.4.4 par la nouvelle ligne suivante:26.4.4 26.4.4 Critres dacceptation Sapplique Sapplique Exclu sauf lorsque 6.1.2.3 a)est appliqu Tableau 3 Classement en tempra

12、ture des pistes sur circuits imprims(pour une temprature ambiante maximale de 40 C)Remplacer la huitime note du tableau par la nouvelle note suivante:Aux sorties des composants dissipant 0,25 W ou plus,soit en fonctionnement normal soit dans les conditions de dfaut,et sur 1,00 mm le long de la piste

13、,soit multiplier la largeur de piste par 3,soit diviser le courant maximal spcifi par 2.Si la piste passe sous le composant,appliquer le facteur spcifi pour les pistes passant sous composants dissipation 0,25W ou plus.Figure 1 Sparation de bornes de circuits de scurit intrinsque et de circuits de sc

14、urit non intrinsque Remplacer la Figure 1b par la nouvelle figure suivante:d1 d2 d3 d4 T T I.S.Circuit I.S.Circuit Non I.S.Circuit 1 2 IEC 001/12 8.2.3 Construction des transformateurs Remplacer le quatrime alina existant par le nouvel alina suivant:Pour la construction du type 2,les enroulements do

15、ivent tre bobins les uns par-dessus les autres avec soit a)une isolation solide entre enroulements conformment au Tableau 5,soit b)un cran raccord la terre(constitu dun clinquant de cuivre)entre les enroulements ou un enroulement quivalent en fils(cran bobin).Lpaisseur du clinquant de cuivre ou de l

16、cran en fils doit tre conforme au Tableau 6.12.1 Gnralits Remplacer les cinquime et sixime alinas existants par les nouveaux alinas suivants:Pour le matriel conforme aux exigences de 6.1.2.3 a),le degr IP doit tre marqu.January 2012 Janvier 2012 Pour le matriel conforme aux exigences de 6.1.2.3 c),le numro de certificat doit inclure le suffixe X conformment aux exigences de marquage de la CEI 60079-0 et les conditions spcifiques dutilisation numres sur le certificat doivent donner les exigences