1、 TECHNICAL REPORT IEC TR 60071-4 First edition2004-06 Insulation co-ordination Part 4:Computational guide to insulation co-ordination and modelling of electrical networks Reference number IEC/TR 60071-4:2004(E)LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED
2、 BY BOOK SUPPLY BUREAU.Publication numbering As from 1 January 1997 all IEC publications are issued with a designation in the 60000 series.For example,IEC 34-1 is now referred to as IEC 60034-1.Consolidated editions The IEC is now publishing consolidated versions of its publications.For example,edit
3、ion numbers 1.0,1.1 and 1.2 refer,respectively,to the base publication,the base publication incorporating amendment 1 and the base publication incorporating amendments 1 and 2.Further information on IEC publications The technical content of IEC publications is kept under constant review by the IEC,t
4、hus ensuring that the content reflects current technology.Information relating to this publication,including its validity,is available in the IEC Catalogue of publications(see below)in addition to new editions,amendments and corrigenda.Information on the subjects under consideration and work in prog
5、ress undertaken by the technical committee which has prepared this publication,as well as the list of publications issued,is also available from the following:IEC Web Site(www.iec.ch)Catalogue of IEC publications The on-line catalogue on the IEC web site(www.iec.ch/searchpub)enables you to search by
6、 a variety of criteria including text searches,technical committees and date of publication.On-line information is also available on recently issued publications,withdrawn and replaced publications,as well as corrigenda.IEC Just Published This summary of recently issued publications(www.iec.ch/onlin
7、e_news/justpub)is also available by email.Please contact the Customer Service Centre(see below)for further information.Customer Service Centre If you have any questions regarding this publication or need further assistance,please contact the Customer Service Centre:Email:custserviec.ch Tel:+41 22 91
8、9 02 11 Fax:+41 22 919 03 00 LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.TECHNICAL REPORT IECTR 60071-4 First edition2004-06 Insulation co-ordination Part 4:Computational guide to insulation co-ordination and modelling of electrica
9、l networks PRICE CODE IEC 2004 Copyright-all rights reserved No part of this publication may be reproduced or utilized in any form or by any means,electronic or mechanical,including photocopying and microfilm,without permission in writing from the publisher.International Electrotechnical Commission,
10、3,rue de Varemb,PO Box 131,CH-1211 Geneva 20,SwitzerlandTelephone:+41 22 919 02 11 Telefax:+41 22 919 03 00 E-mail:inmailiec.ch Web:www.iec.ch XE For price,see current catalogueCommission Electrotechnique InternationaleInternational Electrotechnical Commission LICENSED TO MECON Limited.-RANCHI/BANGA
11、LOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.2 TR 60071-4 IEC:2004(E)CONTENTS FOREWORD.7 1 Scope and object.9 2 Normative references.9 3 Terms and definitions.9 4 List of symbols and acronyms.12 5 Types of overvoltages.12 6 Types of studies.13 6.1 Temporary overvoltages(
12、TOV).14 6.2 Slow-front overvoltages(SFO).14 6.3 Fast-front overvoltages(FFO).15 6.4 Very-fast-front overvoltages(VFFO).15 7 Representation of network components and numerical considerations.15 7.1 General.15 7.2 Numerical considerations.15 7.3 Representation of overhead lines and underground cables.
13、18 7.4 Representation of network components when computing temporary overvoltages.19 7.5 Representation of network components when computing slow-front overvoltages.25 7.6 Representation of network components when computing fast-front transients.30 7.7 Representation of network components when compu
14、ting very-fast-front overvoltages.42 8 Temporary overvoltages analysis.44 8.1 General.44 8.2 Fast estimate of temporary overvoltages.45 8.3 Detailed calculation of temporary overvoltages 2,9.45 9 Slow-front overvoltages analysis.48 9.1 General.48 9.2 Fast methodology to conduct SFO studies.48 9.3 Me
15、thod to be employed.49 9.4 Guideline to conduct detailed statistical methods.49 10 Fast-front overvoltages analysis.52 10.1 General.52 10.2 Guideline to apply statistical and semi-statistical methods.53 11 Very-fast-front overvoltage analysis.58 11.1 General.58 11.2 Goal of the studies to be perform
16、ed.58 11.3 Origin and typology of VFFO.58 11.4 Guideline to perform studies.60 12 Test cases.60 12.1 General.60 12.2 Case 1:TOV on a large transmission system including long lines.60 12.3 Case 2(SFO)Energization of a 500 kV line.68 12.4 Case 3(FFO)Lightning protection of a 500 kV GIS substation.73 12.5 Case 4(VFFO)Simulation of transients in a 765 kV GIS 51.80 LICENSED TO MECON Limited.-RANCHI/BANGALOREFOR INTERNAL USE AT THIS LOCATION ONLY,SUPPLIED BY BOOK SUPPLY BUREAU.TR 60071-4 IEC:2004(E)3