收藏 分享(赏)

Poly-L-lysine solution.pdf

上传人:a****2 文档编号:3616096 上传时间:2024-06-26 格式:PDF 页数:1 大小:27.94KB
下载 相关 举报
Poly-L-lysine solution.pdf_第1页
第1页 / 共1页
亲,该文档总共1页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 Poly-L-lysine solution Cell Culture Tested Product Number P 4707 Storage Temperature 2-8 C Product Description CAS Number:25988-63-0 Molecular weight range:70-150 kDa This product is supplied as a 0.01%sterile-filtered solution in water and is tested for use in cell culture applications.Poly-L-Lysi

2、ne is a charge enhancer,therefore,it can be used for coating many surfaces.When used to coat ELISA plates,it tends to improve binding of IgG.High pH will aid binding to the plates.Certain cells can digest poly-L-lysine,in which case the poly-D-lysine should be used.The lower molecular weight poly-L-

3、lysine(30-70 kDa)is easier to use because it is less viscous in solution,but the higher molecular weight poly-L-lysine(300 kDa)provides more attachment sites per molecule.The mid-range product has a MW range of 70-150 kDa.There might be a small amount of product in the structure,but very little.This

4、 is because the HBr interferes with hydrogen bonding between the amino and carboxyl groups,or between the amino group and other N or O containing moieties.The secondary structures of polyamino acids have never been extensively studied,but it is known that the degree of secondary conformational regul

5、arity depends on the amino acid in the polymer.Precautions and Disclaimer For Laboratory Use Only.Not for drug,household or other uses.Storage/Stability Transition of a high molecular weight poly-L-lysine(degree of polymerization 1,500)in aqueous solution from a helical to a random coiled conformati

6、on occurs under the influence of decreasing pH or increasing temperature.1 Procedure For coating slides with poly-L-lysine,in general,it is recommended to use a 0.01%(w/v)solution.After a 5 minute incubation,the excess solution is removed and the slides are dried at room temperature or in an oven at

7、 gentle heat.Coated slides should be stable for one year if protected from dust.There is no need to sterilze slides coated with poly-L-lysine by autoclaving;simply expose the slides to UV light overnight.If uneven coating occurs,the glass slides may be pretreated with 1 mM magnesium acetate for 2-3

8、hours and then rinsed well before coating.Alternatively,they may be acid washed(hydrochloric acid or sulfuric acid).This treatment should allow for an even coating with the poly-L-lysine solution.This product can also be used to coat tissue culture plasticware.A solution of 0.1 mg/ml is prepared and

9、 0.5 ml is aseptically transferred to a non-tissue culture treated 25 cm2 flask.The flask is gently rocked to evenly coat the surface.After five minutes,the excess solution is removed and the surface is thoroughly rinsed with sterile water and allowed to dry for several hours.References 1.The Merck

10、Index,11th ed.,Entry#7549.CMH/RXR 12/04 Sigma brand products are sold through Sigma-Aldrich,Inc.Sigma-Aldrich,Inc.warrants that its products conform to the information contained in this and other Sigma-Aldrich publications.Purchasermust determine the suitability of the product(s)for their particular use.Additional terms and conditions may apply.Please see reverse side ofthe invoice or packing slip.